The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Magnetically labeled cells can be detected by MR imaging
Abstract
To determine the feasibility of MR imaging of magnetically labeled cells, different cell lines were labeled with monocrystalline iron oxide (MION) particles. Phantoms containing MION labeled cells were then assembled and imaged by MR at 1.5 T using T1‐weighted and T2‐weighted pulse sequences. MION uptake ranged from 8.5 × 10 4 to 2.9 × 10 5 particles/cell for tumor cells (9L and LX1, respectively) to 1.5 × 10 6 to 4.8 × 10 8 particles/cell for “professional phagocytes” (J774 and peritoneal macrophages, respectively). On the T1‐weighted images, cell‐internalized MION appeared hyperintense relative to agar and similar to MION in aqueous solution. On T2‐weighted images, signal intensity varied according to concentration of MION within cells. Cell‐internalized MION caused similar MR signal changes of cells as did free MION; however, at a dose that was an order of magnitude lower, depending on the pulse sequence used. The detectability of MION within cells was approximately 2 ng Fe, which corresponded to 10 5 tumor cells/well or 5 × 10 3 macrophages/well. We conclude that a variety of cells can be efficiently labeled with MION by simple incubation. Intracellular labeling may be used for MR imaging of in vivo cell tracking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rabinowitz, S., Horstmann, H., Gordon, S., & Griffiths, G. (1992) · The Journal of Cell Biology · doi:10.1083/jcb.116.1.95 · Cited by 271
Cited by
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Applications and potential toxicity of magnetic iron oxide nanoparticles
Liu, G., Gao, J., Ai, H., & Chen, X. (2013) · Small · doi:10.1002/smll.201201531 · Cited by 570
Magnetic Iron Oxide Nanoparticle (IONP) Synthesis to Applications: Present and Future
Ajinkya, N., Yu, X., Kaithal, P., Luo, H., Somani, P., & Ramakrishna, S. (2020) · Materials · doi:10.3390/ma13204644 · Cited by 362
Artemov, D., Mori, N., Okollie, B., & Bhujwalla, Z. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10406 · Cited by 351
Metadata
- Authors
- Weissleder, R., Cheng, H., Bogdanova, A., & Bogdanov, A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1997-01
- Volume
- 7
- Issue
- 1
- Pages
- 258-263
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1992295328
- Cited by
- 336
- References
- 1
- FWCI
- 8.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetically labeled cells can be detected by MR imaging. https://app.cochat.ai/papers/10.1002/jmri.1880070140
- The paper
- Weissleder, R., Cheng, H., Bogdanova, A., & Bogdanov, A. (1997). Magnetically labeled cells can be detected by MR imaging. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1880070140
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.