Can a single‐shot black‐blood T2‐weighted spin‐echo echo‐planar imaging sequence with sensitivity encoding replace the respiratory‐triggered turbo spin‐echo sequence for the liver? an optimization and feasibility study
The DOI matches its Crossref record.
Abstract
Purpose: To optimize and assess the feasibility of a single‐shot black‐blood T2‐weighted spin‐echo echo‐planar imaging (SSBB‐EPI) sequence for MRI of the liver using sensitivity encoding (SENSE), and compare the results with those obtained with a T2‐weighted turbo spin‐echo (TSE) sequence. Materials and Methods: Six volunteers and 16 patients were scanned at 1.5T (Philips Intera). In the volunteer study, we optimized the SSBB‐EPI sequence by interactively changing the parameters (i.e., the resolution, echo time (TE), diffusion weighting with low b‐values, and polarity of the phase‐encoding gradient) with regard to distortion, suppression of the blood signal, and sensitivity to motion. The influence of each change was assessed. The optimized SSBB‐EPI sequence was applied in patients (N = 16). A number of items, including the overall image quality (on a scale of 1–5), were used for graded evaluation. In addition, the signal‐to‐noise ratio (SNR) of the liver was calculated. Statistical analysis was carried out with the use of Wilcoxon's signed rank test for comparison of the SSBB‐EPI and TSE sequences, with P = 0.05 considered the limit for significance. Results: The SSBB‐EPI sequence was improved by the following steps: 1) less frequency points than phase‐encoding steps, 2) a b‐factor of 20, and 3) a reversed polarity of the phase‐encoding gradient. In patients, the mean overall image quality score for the optimized SSBB‐EPI (3.5 (range: 1–4)) and TSE (3.6 (range: 3–4)), and the SNR of the liver on SSBB‐EPI (mean ± SD = 7.6 ± 4.0) and TSE (8.9 ± 4.6) were not significantly different (P > .05). Conclusion: Optimized SSBB‐EPI with SENSE proved to be feasible in patients, and the overall image quality and SNR of the liver were comparable to those achieved with the standard respiratory‐triggered T2‐weighted TSE sequence. J. Magn. Reson. Imaging 2005;21:219–229. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
Parikh, T., Drew, S. J., Lee, V. S., Wong, S., Hecht, E. M., Babb, J. S., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070432 · Cited by 560
Taouli, B., Sandberg, A., Stemmer, A., Parikh, T., Wong, S., Xu, J., & Lee, V. S. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21876 · Cited by 167
Coenegrachts, K., Delanote, J., Ter Beek, L., Haspeslagh, M., Bipat, S., Stoker, J., Van Kerkhove, F., Steyaert, L., Rigauts, H., & W Casselman, J. (2007) · The British Journal of Radiology · doi:10.1259/bjr/33156643 · Cited by 149
Detection of hepatic metastasis: manganese-and ferucarbotran-enhanced MR imaging
Choi, J.-Y., Kim, M.-J., Kim, J. H., Kim, S. H., Ko, H.-K., Lim, J. S., Oh, Y. T., Chung, J.-J., Yoo, H. S., Lee, J. T., et al. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.06.016 · Cited by 29
Metadata
- Authors
- Hussain, S. M., De Becker, J., Hop, W. C. J., Dwarkasing, S., & Wielopolski, P. A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2005-02-18
- Volume
- 21
- Issue
- 3
- Pages
- 219-229
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1965012064
- Cited by
- 83
- References
- 0
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.