Multisite fMRI reproducibility of a motor task using identical MR systems
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Purpose: To estimate between‐scanner functional MRI (fMRI) reproducibility in a multisite study. Materials and Methods: A total of five identical 1.5T MR systems were used to repeatedly scan five subjects while performing a finger tapping task. A two‐way (scanners, subjects) random effects analysis of variance (ANOVA) was used to estimate between‐scanner and between‐subject variability on two outcome variables: task‐related mean blood oxygenation level dependent (BOLD) signal change and volume of activation within a motor region‐of‐interest (ROI). Results: Between‐scanner variability of fMRI data accounted for a small proportion of the total variation in the BOLD signal change (8.34%, P = 0.114) and volume of activation (5.46%, P = 0.203). Between‐subject variation accounted for more than half of the total variation for both measurements (57.17% and 54.46%, respectively, P < 0.01). Conclusion: These results support the feasibility of multisite studies using identical scanner systems. J. Magn. Reson. Imaging 2007;26:1122–1126. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bullmore, E. T., Suckling, J., Overmeyer, S., Rabe-Hesketh, S., Taylor, E., & Brammer, M. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.750253 · Cited by 1,088 · cited 1×
“The detection of activated voxels is then extended from voxel to cluster level (12).”
BackgroundSelf-citation
Cited by
Costafreda, S. G., Brammer, M. J., David, A. S., & Fu, C. H. Y. (2008) · Brain Research Reviews · doi:10.1016/j.brainresrev.2007.10.012 · Cited by 772
Self-citationHow reliable are the results from functional magnetic resonance imaging?
Bennett, C. M., & Miller, M. B. (2010) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2010.05446.x · Cited by 577
Clashing diagnostic approaches: DSM-ICD versus RDoC
Lilienfeld, S. O., & Treadway, M. T. (2016) · Annual Review of Clinical Psychology · doi:10.1146/annurev-clinpsy-021815-093122 · Cited by 275
“Even the fMRI research center at which the study is conducted accounts for approximately 8% of the variance in fMRI blood oxygen-level dependent (BOLD) signal results, suggesting that the laboratory itself is a potential source of error in analyses (Costafreda et al. 2007).”
BackgroundThe Research Domain Criteria (RDoC): An analysis of methodological and conceptual challenges
Lilienfeld, S. O. (2014) · Behaviour Research and Therapy · doi:10.1016/j.brat.2014.07.019 · Cited by 248
The role of neuroscience within psychology: A call for inclusiveness over exclusiveness.
Schwartz, S. J., Lilienfeld, S. O., Meca, A., & Sauvigné, K. C. (2016) · American Psychologist · doi:10.1037/a0039678 · Cited by 180
Progress toward openness, transparency, and reproducibility in cognitive neuroscience
Gilmore, R. O., Diaz, M. T., Wyble, B. A., & Yarkoni, T. (2017) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.13325 · Cited by 95
Robinson, O. J., Overstreet, C., Allen, P. S., Letkiewicz, A., Vytal, K., Pine, D. S., & Grillon, C. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.075 · Cited by 64
“…all other between subject differences); research has demonstrated that the data acquired across scanners is replicable (Gradin et al., 2010), can be pooled (Casey et al., 1998) and that the effect of different scanners dwarfs in comparison with between-subject effects (Costafreda et al., 2007).”
BackgroundBias Introduced by Multiple Head Coils in MRI Research: An 8 Channel and 32 Channel Coil Comparison
Panman, J. L., To, Y. Y., van der Ende, E. L., Poos, J. M., Jiskoot, L. C., Meeter, L. H. H., Dopper, E. G. P., Bouts, M. J. R. J., van Osch, M. J. P., Rombouts, S. A. R. B., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00729 · Cited by 46
Metadata
- Authors
- Costafreda, S. G., Brammer, M. J., Vêncio, R. Z. N., Mourão, M. L., Portela, L. A. P., de Castro, C. C., Giampietro, V. P., & Amaro, E.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2007-09-25
- Volume
- 26
- Issue
- 4
- Pages
- 1122-1126
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1981245491
- Cited by
- 56
- References
- 1
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.