The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High‐resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high‐speed incorporation of RF field inhomogeneities (DESPOT1‐HIFI)
Abstract
Purpose: To investigate an alternative approach to correct for flip angle inaccuracies in the driven equilibrium single pulse observation of T1 (DESPOT1) T1 mapping method. Materials and Methods: While DESPOT1 is a robust method for rapid whole‐brain voxelwise mapping of the longitudinal relaxation time, the approach is inherently sensitive to inaccuracies in the transmitted flip angle, defined by the B1 field, which become more severe with increased field. Here we propose an extension of the DESPOT1 technique, involving the additional acquisition of an inversion‐prepared SPGR image alongside the conventional multiangle DESPOT1 data. From these combined data both B1 and T1 may be determined with high accuracy and precision. The method is evaluated at 3T with phantom and in vivo imaging experiments, with derived T1 estimates compared with values calculated from multiple inversion time inversion recovery data. Results: The method provides robust correction of flip angle variations, with less than 5% error compared with reference values for T1 between 300 msec and 2500 msec. Conclusions: The described approach, dubbed DESPOT1‐HIFI, permits whole‐brain T1 mapping at 3T, with 1 mm 3 isotropic voxels, in a clinically feasible time (≈10 minutes) with T1 accuracy greater than 5% and with high precision. J. Magn. Reson. Imaging 2007;26:1106–1111. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
Cited by
MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field
Marques, J. P., Kober, T., Krueger, G., van der Zwaag, W., Van de Moortele, P.-F., & Gruetter, R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.002 · Cited by 1,453
Gleaning multicomponent T1 and T2 information from steady‐state imaging data
Deoni, S. C. L., Rutt, B. K., Arun, T., Pierpaoli, C., & Jones, D. K. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21704 · Cited by 472
Self-citationDeoni, S. C. L., Dean, D. C., O'Muircheartaigh, J., Dirks, H., & Jerskey, B. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.07.037 · Cited by 390
Self-citationUsing high-resolution quantitative mapping of R1 as an index of cortical myelination
Lutti, A., Dick, F., Sereno, M. I., & Weiskopf, N. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.005 · Cited by 346
What are normal relaxation times of tissues at 3 T?
Bojorquez, J. Z., Bricq, S., Acquitter, C., Brunotte, F., Walker, P. M., & Lalande, A. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.08.021 · Cited by 286
Metadata
- Authors
- Deoni, S. C. L.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2007-09-25
- Volume
- 26
- Issue
- 4
- Pages
- 1106-1111
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2036559773
- Cited by
- 236
- References
- 1
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High‐resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high‐speed incorporation of RF field inhomogeneities (DESPOT1‐HIFI). https://app.cochat.ai/papers/10.1002/jmri.21130
- The paper
- Deoni, S. C. L. (2007). High‐resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high‐speed incorporation of RF field inhomogeneities (DESPOT1‐HIFI). Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.21130
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.