Comparison of fat quantification methods: A phantom study at 3.0T
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Purpose: To compare different imaging methods with single‐voxel MR spectroscopy (MRS) for the quantification of fat content in phantoms at 3.0T. Materials and Methods: Imaging and spectroscopy was performed on a GE Signa system. Eleven novel homogeneous fat‐water phantoms were constructed with variation in fat content from 0% to 100%. These were imaged using three techniques and compared with single‐voxel non‐water‐suppressed MRS. Pixel‐by‐pixel maps of fat fraction were produced and mean values compared to MRS‐determined measurements. Preliminary in vivo examinations were subsequently performed in the breast and spine to compare the best imaging technique with MRS. Results: All imaging methods significantly correlated with MRS (P < 0.001): IDEAL (r2 = 0.985), IOP (r2 = 0.888), WS (r2 = 0.939), and FS (r2 = 0.938). In addition, IDEAL provided artifact‐free maps of fat fraction with superior uniformity. In vivo results using IDEAL produced values that were between 9% to 16% of the corresponding MRS values. Conclusion: This work demonstrates that imaging may be utilized as a high‐resolution alternative to MRS for the quantification of fat content. In the future we intend to replace MRS with IDEAL in our clinical studies involving fat measurement. J. Magn. Reson. Imaging 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction of fast MR imaging in the assessment of hepatic steatosis
Fishbein, M. H., Gardner, K. G., Potter, C. J., Schmalbrock, P., & Smith, M. A. (1997) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(96)00224-x · Cited by 226
Schellinger, D., Lin, C. S., Lim, J., Hatipoglu, H. G., Pezzullo, J. C., & Singer, A. J. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.6.01831761 · Cited by 132
Cited by
Yu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Quantification of liver fat content with CT and MRI: state of the art
Starekova, J., Hernando, D., Pickhardt, P. J., & Reeder, S. B. (2021) · Radiology · doi:10.1148/radiol.2021204288 · Cited by 320
Yokoo, T., Bydder, M., Hamilton, G., Middleton, M. S., Gamst, A. C., Wolfson, T., Hassanein, T., Patton, H. M., Lavine, J. E., Schwimmer, J. B., et al. (2009) · Radiology · doi:10.1148/radiol.2511080666 · Cited by 303
Fatty Liver Disease: MR Imaging Techniques for the Detection and Quantification of Liver Steatosis
Cassidy, F. H., Yokoo, T., Aganovic, L., Hanna, R. F., Bydder, M., Middleton, M. S., Hamilton, G., Chavez, A. D., Schwimmer, J. B., & Sirlin, C. B. (2009) · RadioGraphics · doi:10.1148/rg.291075123 · Cited by 271
Quantification of hepatic steatosis with MRI: The effects of accurate fat spectral modeling
Reeder, S. B., Robson, P. M., Yu, H., Shimakawa, A., Hines, C. D., McKenzie, C. A., & Brittain, J. H. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21751 · Cited by 248
Metadata
- Authors
- Bernard, C. P., Liney, G. P., Manton, D. J., Turnbull, L. W., & Langton, C. M.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2007-12-06
- Volume
- 27
- Issue
- 1
- Pages
- 192-197
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2021881096
- Cited by
- 129
- References
- 2
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.