Halving imaging time of whole brain diffusion spectrum imaging and diffusion tractography using simultaneous image refocusing in EPI
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Purpose: To increase the efficiency of densely encoded diffusion imaging of the brain, such as diffusion spectrum imaging (DSI), we time‐multiplex multiple slices within the same readout using simultaneous image refocusing echo‐planar imaging (SIR‐EPI). Materials and Methods: Inefficiency in total scan time results from the long time of diffusion encoding gradient pulses which must be repeated for each and every image. We present a highly efficient multiplexing method, simultaneous image refocusing (SIR), for reducing the total scan time of diffusion imaging by nearly one‐half. SIR DSI is performed in 10 minutes rather than 21 minutes, acceptable for routine clinical application. Results: Two identical studies were completed, comparing conventional single‐slice EPI DSI and SIR‐EPI DSI, showing equal signal‐to‐noise ratio (SNR) and contrast and small differences in registration, likely due to typical subject motion. Comparison of DSI and DTI tractographs showed matching quality and detection of white matter tracts. Conclusion: The net reduction to nearly half the number of diffusion encoding gradient pulses in SIR‐EPI significantly reduces acquisition times of DSI and DTI. J. Magn. Reson. Imaging 2009;29:517–522. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging
Wedeen, V. J., Hagmann, P., Tseng, W. I., Reese, T. G., & Weisskoff, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20642 · Cited by 1,339
Self-citationAnisotropy in high angular resolution diffusion-weighted MRI
Frank, L. R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1125 · Cited by 389
Cited by
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
“The twice-refocused diffusion encoding sequence, first described by Feinberg and Jacob [48], was incorporated into the M-EPI sequence by methods earlier reported using SIR alone [48,49].”
MethodSelf-citationSetsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285
“Multislice methods using slice selection to excite multiple slices simultaneously include the ‘‘wideband’’ imaging (9–11), simultaneous echo refocusing (SER) (12) sometimes referred to as simultaneous image refocused (13) and parallel image reconstruction based multislice imaging (14–17).”
MethodSelf-citationUğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Self-citationPushing the limits of in vivo diffusion MRI for the Human Connectome Project
Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.078 · Cited by 545
“Various methods have been proposed for the simultaneous acquisition of multiple imaging slices including Wideband (Weaver, 1988), Simultaneous Image Refocusing (SIR) (Feinberg et al., 2002; Reese et al., 2009), and parallel imaging based techniques (Larkman et al.”
MethodSelf-citationNTU-90: A high angular resolution brain atlas constructed by q-space diffeomorphic reconstruction
Yeh, F.-C., & Tseng, W.-Y. I. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.021 · Cited by 507
Edlow, B. L., Takahashi, E., Wu, O., Benner, T., Dai, G., Bu, L., Grant, P. E., Greer, D. M., Greenberg, S. M., Kinney, H. C., et al. (2012) · Journal of Neuropathology & Experimental Neurology · doi:10.1097/nen.0b013e3182588293 · Cited by 497
Self-citationUltra-fast MRI of the human brain with simultaneous multi-slice imaging
Feinberg, D. A., & Setsompop, K. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.002 · Cited by 433
Self-citationConserved and variable architecture of human white matter connectivity
Bassett, D. S., Brown, J. A., Deshpande, V., Carlson, J. M., & Grafton, S. T. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.006 · Cited by 366
Improving diffusion MRI using simultaneous multi-slice echo planar imaging
Setsompop, K., Cohen-Adad, J., Gagoski, B. A., Raij, T., Yendiki, A., Keil, B., Wedeen, V. J., & Wald, L. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.033 · Cited by 355
Self-citationMR connectomics: Principles and challenges
Hagmann, P., Cammoun, L., Gigandet, X., Gerhard, S., Ellen Grant, P., Wedeen, V., Meuli, R., Thiran, J.-P., Honey, C. J., & Sporns, O. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.01.014 · Cited by 268
Self-citationInterslice leakage artifact reduction technique for simultaneous multislice acquisitions
Cauley, S. F., Polimeni, J. R., Bhat, H., Wald, L. L., & Setsompop, K. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24898 · Cited by 255
Validation of tractography: Comparison with manganese tracing
Knösche, T. R., Anwander, A., Liptrot, M., & Dyrby, T. B. (2015) · Human Brain Mapping · doi:10.1002/hbm.22902 · Cited by 127
“Another promising improvement in that respect is the recent development of multiplexing [Feinberg et al., 2010; Reese et al., 2009], along with compressed sensing [Doneva et al.”
BackgroundGlenn, G. R., Kuo, L. W., Chao, Y. P., Lee, C. Y., Helpern, J. A., & Jensen, J. H. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4714 · Cited by 58
Metadata
- Authors
- Reese, T. G., Benner, T., Wang, R., Feinberg, D. A., & Wedeen, V. J.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2009-02-25
- Volume
- 29
- Issue
- 3
- Pages
- 517-522
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2019221507
- Cited by
- 58
- References
- 3
- FWCI
- 3.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.