Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 191

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Magnetic resonance imaging and spectroscopy for monitoring liver steatosis

Cowin, Gary J., Jonsson, Julie R., Bauer, Judith D., Ash, Susan, Ali, Azmat, Osland, Emma J., Purdie, David M., Clouston, Andrew D., Powell, Elizabeth E., Galloway, Graham J.·2008·Journal of Magnetic Resonance Imaging

Abstract

Purpose: To compare noninvasive MRI and magnetic resonance spectroscopy (MRS) methods with liver biopsy to quantify liver fat content. Materials and Methods: Quantification of liver fat was compared by liver biopsy, proton MRS, and MRI using in‐phase/out‐of‐phase (IP/OP) and plus/minus fat saturation (±FS) techniques. The reproducibility of each MR measure was also determined. An additional group of overweight patients with steatosis underwent hepatic MRI and MRS before and after a six‐month weight‐loss program. Results: A close correlation was demonstrated between histological assessment of steatosis and measurement of intrahepatocellular lipid (IHCL) by MRS (r s = 0.928, P < 0.0001) and MRI (IP/OP r s = 0.942, P < 0.0001; FS r s = 0.935, P < 0.0001). Following weight reduction, four of five patients with >5% weight loss had a decrease in IHCL of ≥50%. Conclusion: These findings suggest that standard MRI protocols provide a rapid, safe, and quantitative assessment of hepatic steatosis. This is important because MRS is not available on all clinical MRI systems. This will enable noninvasive monitoring of the effects of interventions such as weight loss or pharmacotherapy in patients with fatty liver diseases. J. Magn. Reson. Imaging 2008;28:937–945. © 2008 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.21542

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 191

Metadata

Authors
Cowin, G. J., Jonsson, J. R., Bauer, J. D., Ash, S., Ali, A., Osland, E. J., Purdie, D. M., Clouston, A. D., Powell, E. E., & Galloway, G. J.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2008-09-26
Volume
28
Issue
4
Pages
937-945
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2064623896
Cited by
191
References
4
FWCI
9.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic resonance imaging and spectroscopy for monitoring liver steatosis. https://app.cochat.ai/papers/10.1002/jmri.21542
The paper
Cowin, G. J., Jonsson, J. R., Bauer, J. D., Ash, S., Ali, A., Osland, E. J., Purdie, D. M., Clouston, A. D., Powell, E. E., & Galloway, G. J. (2008). Magnetic resonance imaging and spectroscopy for monitoring liver steatosis. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.21542

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.