CoChat

Quality assessment of high angular resolution diffusion imaging data using bootstrap on Q‐ball reconstruction

Open access
Cohen‐Adad, Julien, Descoteaux, Maxime, Wald, Lawrence L. · 2011 · Journal of Magnetic Resonance Imaging
Cited by 33

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Purpose: To develop a bootstrap method to assess the quality of High Angular Resolution Diffusion Imaging (HARDI) data using Q‐Ball imaging (QBI) reconstruction. Materials and Methods: HARDI data were re‐shuffled using regular bootstrap with jackknife sampling. For each bootstrap dataset, the diffusion orientation distribution function (ODF) was estimated voxel‐wise using QBI reconstruction based on spherical harmonics functions. The reproducibility of the ODF was assessed using the Jensen‐Shannon divergence (JSD) and the angular confidence interval was derived for the first and the second ODF maxima. The sensitivity of the bootstrap method was evaluated on a human subject by adding synthetic noise to the data, by acquiring a map of image signal‐to‐noise ratio (SNR) and by varying the echo time and the b‐value. Results: The JSD was directly linked to the image SNR. The impact of echo times and b‐values was reflected by both the JSD and the angular confidence interval, proving the usefulness of the bootstrap method to evaluate specific features of HARDI data. Conclusion: The bootstrap method can effectively assess the quality of HARDI data and can be used to evaluate new hardware and pulse sequences, perform multifiber probabilistic tractography, and provide reliability metrics to support clinical studies. J. Magn. Reson. Imaging 2011;33:1194–1208. © 2011 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.22535

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 33

Metadata

Authors
Cohen‐Adad, J., Descoteaux, M., & Wald, L. L.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2011-04-20
Volume
33
Issue
5
Pages
1194-1208
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W1995568058
Cited by
33
References
4
FWCI
2.53
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quality assessment of high angular resolution diffusion imaging data using bootstrap on Q‐ball reconstruction. https://app.cochat.ai/papers/10.1002/jmri.22535
The paper
Cohen‐Adad, J., Descoteaux, M., & Wald, L. L. (2011). Quality assessment of high angular resolution diffusion imaging data using bootstrap on Q‐ball reconstruction. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.22535

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.