Signal to noise ratio and uncertainty in diffusion tensor imaging at 1.5, 3.0, and 7.0 Tesla
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Purpose: To compare diffusion tensor imaging (DTI) measurements at ultra high field strength (7 Tesla [T]) in human volunteers with DTI measurements performed at 1.5 and 3 Tesla. Materials and Methods: The signal to noise ratio (SNR) and the uncertainty in fitted DTI parameters fractional anisotropy and primary eigenvector are assessed with tractography based regions of interest, measured in nine volunteers at 1.5T, 3T, and 7T with clinically available hardware configurations. Results: An increase in SNR is observed on the 7T system compared with the 1.5 or 3T system. The measured increase in SNR at 7T is larger than expected from field strength alone, indicating the large influence of improved receive coil hardware. Additionally, while the average fractional anisotropy remains relatively constant across field strengths, a decrease in uncertainty in the fitted values for fractional anisotropy and the principal eigenvector of the DTI tensor was found. Increased spatial heterogeneity of signal intensities is observed at 7T. Conclusion: Given the current hardware constraints, DTI at ultra‐high field strengths is possible with improved performance in selected regions of interest. J. Magn. Reson. Imaging 2011;33:1456–1463. © 2011 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Cited by
A hitchhiker's guide to diffusion tensor imaging
Soares, J. M., Marques, P., Alves, V., & Sousa, N. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00031 · Cited by 893
Ultra-High-Field MR Neuroimaging
Balchandani, P., & Naidich, T. P. (2015) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4180 · Cited by 193
“5T.(20) Figure 5 illustrates streamlines generated from diffusion-weighted data obtained on a FIG 1.”
BackgroundDiffusion weighted magnetic resonance imaging and its recent trend-a survey.
Chilla, G. S. V. N., Tan, C. H., Xu, C., & Poh, C. L. (2015) · PubMed · doi:10.3978/j.issn.2223-4292.2015.03.01 · Cited by 175
Palacios, E. M., Martin, A. J., Boss, M. A., Ezekiel, F., Chang, Y. S., Yuh, E. L., Vassar, M. J., Schnyer, D. M., MacDonald, C. L., Crawford, K. L., et al. (2017) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5025 · Cited by 110
Chung, A. W., Seunarine, K. K., & Clark, C. A. (2016) · Human Brain Mapping · doi:10.1002/hbm.23328 · Cited by 63
“Many have demonstrated SNR to also vary across white matter regions considerably [Ding et al., 2007; Farrell et al., 2007; Fushimi et al., 2007; Polders et al., 2011].”
BackgroundAutomated tractography of the cingulate bundle in Alzheimer's disease: a multicenter DTI study
Fischer, F. U., Scheurich, A., Wegrzyn, M., Schermuly, I., Bokde, A. L. W., Klöppel, S., Pouwels, P. J. W., Teipel, S., Yakushev, I., & Fellgiebel, A. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23621 · Cited by 34
Metadata
- Authors
- Polders, D. L., Leemans, A., Hendrikse, J., Donahue, M. J., Luijten, P. R., & Hoogduin, J. M.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2011-05-17
- Volume
- 33
- Issue
- 6
- Pages
- 1456-1463
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2023442941
- Cited by
- 129
- References
- 2
- FWCI
- 6.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.