CoChat

Coronary MR angiography using citrate‐coated very small superparamagnetic iron oxide particles as blood‐pool contrast agent: Initial experience in humans

Wagner, Moritz, Wagner, Susanne, Schnorr, Jörg, Schellenberger, Eyk, Kivelitz, Dietmar, Krug, Lasse, Dewey, Marc, Laule, Michael, Hamm, Bernd, Taupitz, Matthias · 2011 · Journal of Magnetic Resonance Imaging
Cited by 69

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Purpose: To evaluate very small superparamagnetic iron oxide particles (VSOP‐C184) as blood‐pool contrast agent for coronary MR angiography (CMRA) in humans. Materials and Methods: Six healthy volunteers and 14 patients with suspected coronary artery disease underwent CMRA after administration of VSOP‐C184 at the following doses: 20 μmol Fe/kg (4 patients), 40 μmol Fe/kg (5 patients), 45 μmol Fe/kg (6 healthy volunteers), and 60 μmol Fe/kg (5 patients). In healthy volunteers, contrast‐to‐noise ratio (CNR), signal‐to‐noise ratio (SNR), and vessel edge definition (VED) of contrast‐enhanced CMRA were compared with non–contrast‐enhanced CMRA. In patients, a per‐segment intention‐to‐diagnose evaluation of contrast‐enhanced CMRA for detection of significant coronary stenosis (≥50%) was performed. Results: Three healthy volunteers (45 μmol Fe/kg VSOP‐C184) and two patients (60 μmol Fe/kg VSOP‐C184) had adverse events of mild or moderate intensity. VSOP‐C184 significantly increased CNR (15.1 ± 4.6 versus 6.9 ± 1.9; P = 0.010), SNR (21.7 ± 5.3 versus 15.4 ± 1.6; P = 0.048), and VED (2.3 ± 0.6 versus 1.2 ± 0.2; P < 0.001) compared with non–contrast‐enhanced CMRA. In patients, contrast‐enhanced CMRA yielded sensitivity, specificity, and diagnostic accuracy for detection of significant coronary stenosis of 86.7%, 71.0%, 73.1%, respectively. Conclusion: CMRA using VSOP‐C184 was feasible and yielded moderate diagnostic accuracy for detection of significant coronary stenosis within this proof‐of‐concept setting. J. Magn. Reson. Imaging 2011;. © 2011 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.22683

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Wagner, M., Wagner, S., Schnorr, J., Schellenberger, E., Kivelitz, D., Krug, L., Dewey, M., Laule, M., Hamm, B., & Taupitz, M.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2011-07-18
Volume
34
Issue
4
Pages
816-823
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2018709506
Cited by
69
References
2
FWCI
4.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.