Coronary MR angiography using citrate‐coated very small superparamagnetic iron oxide particles as blood‐pool contrast agent: Initial experience in humans
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Purpose: To evaluate very small superparamagnetic iron oxide particles (VSOP‐C184) as blood‐pool contrast agent for coronary MR angiography (CMRA) in humans. Materials and Methods: Six healthy volunteers and 14 patients with suspected coronary artery disease underwent CMRA after administration of VSOP‐C184 at the following doses: 20 μmol Fe/kg (4 patients), 40 μmol Fe/kg (5 patients), 45 μmol Fe/kg (6 healthy volunteers), and 60 μmol Fe/kg (5 patients). In healthy volunteers, contrast‐to‐noise ratio (CNR), signal‐to‐noise ratio (SNR), and vessel edge definition (VED) of contrast‐enhanced CMRA were compared with non–contrast‐enhanced CMRA. In patients, a per‐segment intention‐to‐diagnose evaluation of contrast‐enhanced CMRA for detection of significant coronary stenosis (≥50%) was performed. Results: Three healthy volunteers (45 μmol Fe/kg VSOP‐C184) and two patients (60 μmol Fe/kg VSOP‐C184) had adverse events of mild or moderate intensity. VSOP‐C184 significantly increased CNR (15.1 ± 4.6 versus 6.9 ± 1.9; P = 0.010), SNR (21.7 ± 5.3 versus 15.4 ± 1.6; P = 0.048), and VED (2.3 ± 0.6 versus 1.2 ± 0.2; P < 0.001) compared with non–contrast‐enhanced CMRA. In patients, contrast‐enhanced CMRA yielded sensitivity, specificity, and diagnostic accuracy for detection of significant coronary stenosis of 86.7%, 71.0%, 73.1%, respectively. Conclusion: CMRA using VSOP‐C184 was feasible and yielded moderate diagnostic accuracy for detection of significant coronary stenosis within this proof‐of‐concept setting. J. Magn. Reson. Imaging 2011;. © 2011 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schnorr, J., Wagner, S., Abramjuk, C., Wojner, I., Schink, T., Kroencke, T. J., Schellenberger, E., Hamm, B., Pilgrimm, H., & Taupitz, M. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000133944.30119.cc · Cited by 54
Self-citationKlein, C., Schalla, S., Schnackenburg, B., Bornstedt, A., Hoffmann, V., Fleck, E., & Nagel, E. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10317 · Cited by 29 · cited 2×
“In a study of Klein et al, NC100150-enhanced CMRA yielded good sensitivity of 84% and specificity of 92% in ten patients with known coronary artery disease (7).”
BackgroundMethod
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Magnetic iron oxide nanoparticles for drug delivery: applications and characteristics
Vangijzegem, T., Stanicki, D., & Laurent, S. (2019) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2019.1554647 · Cited by 548
Sandiford, L., Phinikaridou, A., Protti, A., Meszaros, L. K., Cui, X., Yan, Y., Frodsham, G., Williamson, P. A., Gaddum, N., Botnar, R. M., et al. (2013) · ACS Nano · doi:10.1021/nn3046055 · Cited by 268
Wáng, Y. X. J., & Idée, J.-M. (2017) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2017.02.09 · Cited by 247
“NC100150 (Clariscan, Nycomed, Norway) and (VSOP C184, Ferropharm, Germany) have been designed and clinically tested for MR angiography and blood pool imaging (27,28), but did not achieve regulatory approval.”
BackgroundCurrent status of superparamagnetic iron oxide contrast agents for liver magnetic resonance imaging
Wang, Y.-X. J. (2015) · World Journal of Gastroenterology · doi:10.3748/wjg.v21.i47.13400 · Cited by 233
Nanoparticles for Imaging: top or Flop?
Kiessling, F., Mertens, M. E., Grimm, J., & Lammers, T. (2014) · Radiology · doi:10.1148/radiol.14131520 · Cited by 228
Wang, Z., Qiao, R., Tang, N., Lu, Z., Wang, H., Zhang, Z., Xue, X., Huang, Z., Zhang, S., Zhang, G., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.02.037 · Cited by 212
Kratz, H., Taupitz, M., Ariza de Schellenberger, A., Kosch, O., Eberbeck, D., Wagner, S., Trahms, L., Hamm, B., & Schnorr, J. (2018) · PLoS ONE · doi:10.1371/journal.pone.0190214 · Cited by 92
Self-citationApplications and Efficacy of Iron Oxide Nanoparticles in the Treatment of Brain Tumors
Varalli, L., Berlet, R., Abenojar, E., McDaid, J., Gascoigne, D. A., Bailes, J., & Aksenov, D. P. (2025) · Pharmaceutics · doi:10.3390/pharmaceutics17040499 · Cited by 23
Metadata
- Authors
- Wagner, M., Wagner, S., Schnorr, J., Schellenberger, E., Kivelitz, D., Krug, L., Dewey, M., Laule, M., Hamm, B., & Taupitz, M.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2011-07-18
- Volume
- 34
- Issue
- 4
- Pages
- 816-823
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2018709506
- Cited by
- 69
- References
- 2
- FWCI
- 4.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.