CoChat

Central gland and peripheral zone prostate tumors have significantly different quantitative imaging signatures on 3 tesla endorectal, in vivo T2‐weighted MR imagery

Open access
Viswanath, Satish E., Bloch, Nicholas B., Chappelow, Jonathan C., Toth, Robert, Rofsky, Neil M., Genega, Elizabeth M., Lenkinski, Robert E., Madabhushi, Anant · 2012 · Journal of Magnetic Resonance Imaging
Cited by 124

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Purpose: To identify and evaluate textural quantitative imaging signatures (QISes) for tumors occurring within the central gland (CG) and peripheral zone (PZ) of the prostate, respectively, as seen on in vivo 3 Tesla (T) endorectal T2‐weighted (T2w) MRI. Materials and Methods: This study used 22 preoperative prostate MRI data sets (16 PZ, 6 CG) acquired from men with confirmed prostate cancer (CaP) and scheduled for radical prostatectomy (RP). The prostate region‐of‐interest (ROI) was automatically delineated on T2w MRI, following which it was corrected for intensity‐based acquisition artifacts. An expert pathologist manually delineated the dominant tumor regions on ex vivo sectioned and stained RP specimens as well as identified each of the studies as either a CG or PZ CaP. A nonlinear registration scheme was used to spatially align and then map CaP extent from the ex vivo RP sections onto the corresponding MRI slices. A total of 110 texture features were then extracted on a per‐voxel basis from all T2w MRI data sets. An information theoretic feature selection procedure was then applied to identify QISes comprising T2w MRI textural features specific to CG and PZ CaP, respectively. The QISes for CG and PZ CaP were evaluated by means of Quadratic Discriminant Analysis (QDA) on a per‐voxel basis against the ground truth for CaP on T2w MRI, mapped from corresponding histology. Results: The QDA classifier yielded an area under the Receiver Operating characteristic curve of 0.86 for the CG CaP studies, and 0.73 for the PZ CaP studies over 25 runs of randomized three‐fold cross‐validation. By comparison, the accuracy of the QDA classifier was significantly lower when (a) using all 110 texture features (with no feature selection applied), as well as (b) a randomly selected combination of texture features. Conclusion: CG and PZ prostate cancers have significantly differing textural quantitative imaging signatures on T2w endorectal in vivo MRI. J. Magn. Reson. Imaging 2012;36:213–224. © 2012 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.23618

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 124

Metadata

Authors
Viswanath, S. E., Bloch, N. B., Chappelow, J. C., Toth, R., Rofsky, N. M., Genega, E. M., Lenkinski, R. E., & Madabhushi, A.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2012-02-15
Volume
36
Issue
1
Pages
213-224
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2016494145
Cited by
124
References
3
FWCI
7.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.