CoChat

Test–retest stability analysis of resting brain activity revealed by blood oxygen level‐dependent functional MRI

Open access
Li, Zhengjun, Kadivar, Aniseh, Pluta, John, Dunlop, John, Wang, Ze · 2012 · Journal of Magnetic Resonance Imaging
Cited by 102

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Purpose: To assess test–retest stability of four functional magnetic resonance imaging (fMRI)‐derived resting brain activity metrics: the seed‐region‐based functional connectivity (SRFC), independent component analysis (ICA)‐derived network‐based FC (NTFC), regional homogeneity (ReHo), and the amplitude of low frequency fluctuation (ALFF). Methods: Simulations were used to assess the sensitivity of SRFC, ReHo, and ALFF to noise interference. Repeat resting blood oxygen level‐dependent (BOLD) fMRI were acquired from 32 healthy subjects. The intraclass correlation coefficient (ICC) was used to assess the stability of the four metrics. Results: Random noise yielded small random SRFC, small but consistent ReHo and ALFF. A neighborhood size greater than 20 voxels should be used for calculating ReHo in order to reduce the noise interference. Both the anterior cingulate cortex (ACC) and posterior cingulate cortex (PCC)‐based SRFC were reproducible in more spatially extended regions than ICA NTFC. The two regional spontaneous brain activity (SBA) measures, ReHo and ALFF, showed test–retest reproducibility in almost the whole gray matter. Conclusion: SRFC, ReHo, and ALFF are robust to random noise interference. The neighborhood size for calculating ReHo should be larger than 20 voxels. ICC > 0.5 and cluster size > 11 should be used to assess the ICC maps for ACC/PCC SRFC, ReHo, and ALFF. BOLD fMRI‐based SBA can be reliably measured using ACC/PCC SRFC, ReHo, and ALFF after 2 months. J. Magn. Reson. Imaging 2012;36:344–354. ©2012 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.23670

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 102

Metadata

Authors
Li, Z., Kadivar, A., Pluta, J., Dunlop, J., & Wang, Z.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2012-04-25
Volume
36
Issue
2
Pages
344-354
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2132827635
Cited by
102
References
17
FWCI
4.61
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Test–retest stability analysis of resting brain activity revealed by blood oxygen level‐dependent functional MRI. https://app.cochat.ai/papers/10.1002/jmri.23670
The paper
Li, Z., Kadivar, A., Pluta, J., Dunlop, J., & Wang, Z. (2012). Test–retest stability analysis of resting brain activity revealed by blood oxygen level‐dependent functional MRI. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.23670

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.