Volumetric arterial wall shear stress calculation based on cine phase contrast MRI
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Purpose: To assess the accuracy and precision of a volumetric wall shear stress (WSS) calculation method applied to cine phase contrast magnetic resonance imaging (PC‐MRI) data. Materials and Methods: Volumetric WSS vectors were calculated in software phantoms. WSS algorithm parameters were optimized and the influence of spatial resolution and segmentation was evaluated. Subsequently, 2D cine PC‐MRI data in the carotid and the aorta at varying spatial resolutions were obtained (n = 2) and compared with the simulations. Finally, volumetric WSS was calculated in 3D cine PC‐MRI data of the carotid bifurcation and the aorta (n = 6). Results: We found that at least 8 voxels across the diameter are required to obtain a WSS accuracy of 5% and a precision of 20% in software phantoms. Systematic WSS quantification errors up to 40% were found in the case of segmentation errors. The in vivo measurements using 2D cine PC‐MRI exhibited WSS increase at increasing spatial resolutions, similar to the results in software phantoms. Volumetric WSS vectors were successfully calculated in three healthy carotid bifurcations and aortas. Conclusion: The effects of resolution and segmentation on the accuracy and precision of the WSS algorithm were quantified. We were able to calculate volumetric WSS in the carotid bifurcation and the aorta. J. Magn. Reson. Imaging 2015;41:505–516.© 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yushkevich, P. A., Piven, J., Hazlett, H. C., Smith, R. G., Ho, S., Gee, J. C., & Gerig, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.015 · Cited by 8,868 · cited 1×
“The segmentations of 3D cine PC-MRI data in systole (created using the active contour evolution algorithm in ITK-SNAP (26)) were filtered with a Laplacian filter (27) to reduce irregularities and discretization effects and the results were manually checked by overlaying them on all image types (velocity, magnitude ima…”
MethodSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 2×
“Another limitation can be the use of parallel imaging (SENSE), which may decrease the SNR (42).”
BackgroundHemodynamic shear stress and its role in atherosclerosis
Malek, A. M. (1999) · JAMA · doi:10.1001/jama.282.21.2035 · Cited by 3,650 · cited 1×
“High WSS is believed to be a stimulus for physiological remodeling of the blood vessel wall and for maintaining an atheroprotective phenotype (4).”
BackgroundThe rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494 · cited 1×
“Additionally, noise (normal distribution, the variance set to 10% of the venc (22,23)) was added to investigate its effect on WSS estimates.”
MethodChiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280 · cited 1×
“THE EFFECT OF BLOOD FLOW on the vascular endothelium has been proposed to be a critical determinant of vascular disease progression in atherosclerosis and aneurysms (1,2).”
BackgroundReinsch, C. H. (1967) · Numerische Mathematik · doi:10.1007/bf02162161 · Cited by 2,236
Chatzizisis, Y. S., Coskun, A. U., Jonas, M., Edelman, E. R., Feldman, C. L., & Stone, P. H. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.02.059 · Cited by 1,483
Li, C., Huang, R., Ding, Z., Gatenby, J. C., Metaxas, D. N., & Gore, J. C. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2011.2146190 · Cited by 1,285 · cited 1×
“A 2D level set evolution algorithm (25) was used to segment the lumen for each transversal slice in the high-resolution 2D cine PC-MRI datasets during systole.”
MethodMeng, H., Tutino, V. M., Xiang, J., & Siddiqui, A. (2014) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3558 · Cited by 955
Phase contrast cine magnetic resonance imaging.
Pelc, N. J., Herfkens, R. J., Shimakawa, A. S., & Enzmann, D. R. (1991) · PubMed · Cited by 610
Boussel, L., Rayz, V., McCulloch, C., Martin, A., Acevedo-Bolton, G., Lawton, M., Higashida, R., Smith, W. S., Young, W. L., & Saloner, D. (2008) · Stroke · doi:10.1161/strokeaha.108.521617 · Cited by 535 · cited 2×
“THE EFFECT OF BLOOD FLOW on the vascular endothelium has been proposed to be a critical determinant of vascular disease progression in atherosclerosis and aneurysms (1,2).”
BackgroundStalder, A. F., Russe, M. F., Frydrychowicz, A., Bock, J., Hennig, J., & Markl, M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21778 · Cited by 474 · cited 9×
“As was shown in simulations by Stalder et al (14) and later by Petersson and Dyverfeldt (18), several factors hamper the calculation of WSS. Errors arise due to segmentation inaccuracies, low spatial resolution, signal-to-noise ratio (SNR), spatial filtering, and, to a lesser extent, the choice of encoding velocities…”
BackgroundMethodInfluentialBicuspid Aortic Valve Is Associated With Altered Wall Shear Stress in the Ascending Aorta
Barker, A. J., Markl, M., Bürk, J., Lorenz, R., Bock, J., Bauer, S., Schulz-Menger, J., & von Knobelsdorff-Brenkenhoff, F. (2012) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.112.973370 · Cited by 454 · cited 1×
“Both low and oscillating WSS patterns have been reported to correlate with atherosclerosis (4–7) and aortic dilatation (8,9), whereas high WSS was found in aortas with bicuspid valves (9,10).”
BackgroundReneman, R. S., Arts, T., & Hoeks, A. P. G. (2006) · Journal of Vascular Research · doi:10.1159/000091648 · Cited by 431
Principles of Magnetic Resonance Imaging
Liang, Z.-P., & Lauterbur, P. C. (1999) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470545652 · Cited by 412
Gnasso, A., Carallo, C., Irace, C., Spagnuolo, V., De Novara, G., Mattioli, P. L., & Pujia, A. (1996) · Circulation · doi:10.1161/01.cir.94.12.3257 · Cited by 308
Boussel, L., Rayz, V. L., Martin, A. J., Acevedo‐Bolton, G., Lawton, M. T., Higashida, R. T., Smith, W. S., Young, W. L., & Saloner, D. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21861 · Cited by 253 · cited 3×
“Approaches in which the WSS vector is calculated at each wall position were presented by Boussel et al (15) in intracranial aneurysms and Bieging et al (16) in the ascending aorta.”
MethodResultBürk, J., Blanke, P., Stankovic, Z., Barker, A., Russe, M., Geiger, J., Frydrychowicz, A., Langer, M., & Markl, M. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-84 · Cited by 241 · cited 1×
“Both low and oscillating WSS patterns have been reported to correlate with atherosclerosis (4–7) and aortic dilatation (8,9), whereas high WSS was found in aortas with bicuspid valves (9,10).”
BackgroundHemodynamic Patterns of Anterior Communicating Artery Aneurysms: A Possible Association with Rupture
Castro, M. A., Putman, C. M., Sheridan, M. J., & Cebral, J. R. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1323 · Cited by 227 · cited 1×
“In addition, spatial WSS gradients have been suggested to relate to intracranial aneurysm progression (2) and rupture risk (11), although compelling evidence is still lacking (12).”
BackgroundBarker, A. J., Lanning, C. J., & Shandas, R. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9854-3 · Cited by 204 · cited 1×
“Both low and oscillating WSS patterns have been reported to correlate with atherosclerosis (4–7) and aortic dilatation (8,9), whereas high WSS was found in aortas with bicuspid valves (9,10).”
BackgroundPapathanasopoulou, P., Zhao, S., Köhler, U., Robertson, M. B., Long, Q., Hoskins, P. R., Xu, X. Y., & Marshall, I. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10243 · Cited by 194 · cited 1×
“Other methods combine the interpolation and fitting step by fifth-order polynomial fitting of the 3D cine PC-MRI velocities (29,30), but up to now, this approach has only been applied in phantom datasets.”
MethodBogren, H. G., & Buonocore, M. H. (1999) · Journal of Magnetic Resonance Imaging · Cited by 191 · cited 1×
“The use of only three points on the inward normal may smooth complex in vivo velocity profiles (32), resulting in WSS underestimations.”
BackgroundFrydrychowicz, A., Stalder, A. F., Russe, M. F., Bock, J., Bauer, S., Harloff, A., Berger, A., Langer, M., Hennig, J., & Markl, M. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21790 · Cited by 180 · cited 1×
“This effect is suggested to primarily relate to the local wall shear stress (WSS), ie, the tangential force per surface area acting on the endothelial cells (3).”
BackgroundAssessment of the accuracy of MRI wall shear stress estimation using numerical simulations
Petersson, S., Dyverfeldt, P., & Ebbers, T. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23610 · Cited by 176 · cited 6×
“As was shown in simulations by Stalder et al (14) and later by Petersson and Dyverfeldt (18), several factors hamper the calculation of WSS. Errors arise due to segmentation inaccuracies, low spatial resolution, signal-to-noise ratio (SNR), spatial filtering, and, to a lesser extent, the choice of encoding velocities…”
BackgroundMethodResultInfluentialDetermination of wall shear stress in the aorta with the use of MR phase velocity mapping
Osinnski, J. N., Ku, D. N., Mukundan, S., Loth, F., & Pettigrew, R. I. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050605 · Cited by 174 · cited 2×
“The availability of volumetric 3D WSS information is an improvement over existing 2D and slice-based WSS calculation methods (14,17).”
MethodHofman, M. B. M., Visser, F. C., van Rossum, A. C., Vink, G. Q. M., Sprenger, M., & Westerhof, N. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330606 · Cited by 152 · cited 1×
“A guideline on resolution of flow quantification using PC-MRI suggested at least 3 voxels across the diameter (33), and 16 isotropic voxels over the vessel lumen area ( 4.”
MethodIn vivo three‐dimensional MR wall shear stress estimation in ascending aortic dilatation
Bieging, E. T., Frydrychowicz, A. P., Wentland, A. L., Landgraf, B. R., Johnson, K. M., Wieben, O. E., & François, C. J. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22485 · Cited by 137 · cited 4×
“Approaches in which the WSS vector is calculated at each wall position were presented by Boussel et al (15) in intracranial aneurysms and Bieging et al (16) in the ascending aorta.”
MethodResultInfluentialCheng, C. P., Parker, D., & Taylor, C. A. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1511239 · Cited by 130 · cited 3×
“Natural neighbor interpolation provides a continuous first derivative in contrast to methods using Lagrangian interpolation (28).”
BackgroundMethodIsoda, H., Ohkura, Y., Kosugi, T., Hirano, M., Alley, M. T., Bammer, R., Pelc, N. J., Namba, H., & Sakahara, H. (2009) · Neuroradiology · doi:10.1007/s00234-009-0634-4 · Cited by 108
Oyre, S., Ringgaard, S., Kozerke, S., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00207-1 · Cited by 107 · cited 2×
“WSS direction and magnitude can be obtained from spatial derivatives of these velocities on the vessel wall (13).”
BackgroundResultWall shear stress estimated with phase contrast MRI in an in vitro and in vivo intracranial aneurysm
van Ooij, P., Potters, W. V., Guédon, A. C. P., Schneiders, J. J., Marquering, H. A., Majoie, C. B. L. M., VanBavel, E., & Nederveen, A. J. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24051 · Cited by 87 · cited 1×
“The next step towards clinical applicability will be to further validate the described method on complex geometries, where the estimates can be compared with CFD simulations, which are generally considered the gold standard (15,44,45).”
MethodSelf-citationvan Ooij, P., Guédon, A. C. P., Poelma, C., Schneiders, J. J., Rutten, M. C. M., Marquering, H. A., Majoie, C. B. L. M., VanBavel, E., & Nederveen, A. J. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1706 · Cited by 80
Self-citationStrecker, C., Harloff, A., Wallis, W., & Markl, M. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23735 · Cited by 60
Duivenvoorden, R., VanBavel, E., de Groot, E., Stroes, E. S. G., Disselhorst, J. A., Hutten, B. A., Laméris, J. S., Kastelein, J. J. P., & Nederveen, A. J. (2010) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.109.916304 · Cited by 47 · cited 1×
“This is relatively long compared to literature (6,13,15,16,31), which may be related to the parabolic velocity profiles that were used in our simulations.”
ResultSelf-citationCo-registration of the distribution of wall shear stress and 140 complex plaques of the aorta
Markl, M., Brendecke, S. M., Simon, J., Barker, A. J., Weiller, C., & Harloff, A. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2013.05.001 · Cited by 40
Box, F. M. A., van der Geest, R. J., van der Grond, J., van Osch, M. J. P., Zwinderman, A. H., Palm‐Meinders, I. H., Doornbos, J., Blauw, G. J., van Buchem, M. A., & Reiber, J. H. C. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21086 · Cited by 26
Subject‐specific aortic wall shear stress estimations using semi‐automatic segmentation
Renner, J., Najafabadi, H. N., Modin, D., Länne, T., & Karlsson, M. (2012) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2012.01146.x · Cited by 12 · cited 1×
“Other PC-MRI-based methods report even lower values (16,36), while CFD based WSS calculations report higher WSS values in the aorta (37).”
Cited by
4D flow cardiovascular magnetic resonance consensus statement
Dyverfeldt, P., Bissell, M., Barker, A. J., Bolger, A. F., Carlhäll, C.-J., Ebbers, T., Francios, C. J., Frydrychowicz, A., Geiger, J., Giese, D., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0174-5 · Cited by 877
Cardiovascular magnetic resonance phase contrast imaging
Nayak, K. S., Nielsen, J.-F., Bernstein, M. A., Markl, M., D. Gatehouse, P., M. Botnar, R., Saloner, D., Lorenz, C., Wen, H., S. Hu, B., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0172-7 · Cited by 264
Metadata
- Authors
- Potters, W. V., van Ooij, P., Marquering, H., vanBavel, E., & Nederveen, A. J.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2014-01-17
- Volume
- 41
- Issue
- 2
- Pages
- 505-516
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2137913387
- Cited by
- 177
- References
- 37
- FWCI
- 10.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.