CoChat

Advances in MRI around metal

Open access
Jungmann, Pia M., Agten, Christoph A., Pfirrmann, Christian W., Sutter, Reto · 2017 · Journal of Magnetic Resonance Imaging
Cited by 227

The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.

Abstract

The prevalence of orthopedic metal implants is continuously rising in the aging society. Particularly the number of joint replacements is increasing. Although satisfying long‐term results are encountered, patients may suffer from complaints or complications during follow‐up, and often undergo magnetic resonance imaging (MRI). Yet metal implants cause severe artifacts on MRI, resulting in signal‐loss, signal‐pileup, geometric distortion, and failure of fat suppression. In order to allow for adequate treatment decisions, metal artifact reduction sequences (MARS) are essential for proper radiological evaluation of postoperative findings in these patients. During recent years, developments of musculoskeletal imaging have addressed this particular technical challenge of postoperative MRI around metal. Besides implant material composition, configuration and location, selection of appropriate MRI hardware, sequences, and parameters influence artifact genesis and reduction. Application of dedicated metal artifact reduction techniques including high bandwidth optimization, view angle tilting (VAT), and the multispectral imaging techniques multiacquisition variable‐resonance image combination (MAVRIC) and slice‐encoding for metal artifact correction (SEMAC) may significantly reduce metal‐induced artifacts, although at the expense of signal‐to‐noise ratio and/or acquisition time. Adding advanced image acquisition techniques such as parallel imaging, partial Fourier transformation, and advanced reconstruction techniques such as compressed sensing further improves MARS imaging in a clinically feasible scan time. This review focuses on current clinically applicable MARS techniques. Understanding of the main principles and techniques including their limitations allows a considerate application of these techniques in clinical practice. Essential orthopedic metal implants and postoperative MR findings around metal are presented and highlighted with clinical examples. Level of Evidence: 4 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2017;46:972–991.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.25708

Cites

66 of 66 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 66 references

Cited by

Metadata

Authors
Jungmann, P. M., Agten, C. A., Pfirrmann, C. W., & Sutter, R.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2017-03-25
Volume
46
Issue
4
Pages
972-991
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2603054283
Cited by
227
References
66
FWCI
10.03
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.