Advances in MRI around metal
Open accessThe DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Abstract
The prevalence of orthopedic metal implants is continuously rising in the aging society. Particularly the number of joint replacements is increasing. Although satisfying long‐term results are encountered, patients may suffer from complaints or complications during follow‐up, and often undergo magnetic resonance imaging (MRI). Yet metal implants cause severe artifacts on MRI, resulting in signal‐loss, signal‐pileup, geometric distortion, and failure of fat suppression. In order to allow for adequate treatment decisions, metal artifact reduction sequences (MARS) are essential for proper radiological evaluation of postoperative findings in these patients. During recent years, developments of musculoskeletal imaging have addressed this particular technical challenge of postoperative MRI around metal. Besides implant material composition, configuration and location, selection of appropriate MRI hardware, sequences, and parameters influence artifact genesis and reduction. Application of dedicated metal artifact reduction techniques including high bandwidth optimization, view angle tilting (VAT), and the multispectral imaging techniques multiacquisition variable‐resonance image combination (MAVRIC) and slice‐encoding for metal artifact correction (SEMAC) may significantly reduce metal‐induced artifacts, although at the expense of signal‐to‐noise ratio and/or acquisition time. Adding advanced image acquisition techniques such as parallel imaging, partial Fourier transformation, and advanced reconstruction techniques such as compressed sensing further improves MARS imaging in a clinically feasible scan time. This review focuses on current clinically applicable MARS techniques. Understanding of the main principles and techniques including their limitations allows a considerate application of these techniques in clinical practice. Essential orthopedic metal implants and postoperative MR findings around metal are presented and highlighted with clinical examples. Level of Evidence: 4 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2017;46:972–991.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
MR Procedures: Biologic Effects, Safety, and Patient Care
Shellock, F. G., & Crues, J. V. (2004) · Radiology · doi:10.1148/radiol.2323030830 · Cited by 563
Metal-Induced Artifacts in MRI
Hargreaves, B. A., Worters, P. W., Pauly, K. B., Pauly, J. M., Koch, K. M., & Gold, G. E. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.7364 · Cited by 559 · cited 10×
“In the algorithmic approach to diagnosis and management of metal-on-metal arthroplasty published in 2012 by the hip society,113 imaging should include ultrasound or metal artifact reduction sequence MRI in addition to plain radiography.113,114,144,145 MARS sequences including VAT and SEMAC have been shown to be useful…”
BackgroundInfluentialLee, M.-J., Kim, S., Lee, S.-A., Song, H.-T., Huh, Y.-M., Kim, D.-H., Han, S. H., & Suh, J.-S. (2007) · RadioGraphics · doi:10.1148/rg.273065087 · Cited by 513
SEMAC: Slice encoding for metal artifact correction in MRI
Lu, W., Pauly, K. B., Gold, G. E., Pauly, J. M., & Hargreaves, B. A. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21967 · Cited by 392 · cited 3×
“In addition to in-plane artifacts, SEMAC reduces throughplane distortions by correcting for signal that is excited in wrong slice positions.(71,72,81) SEMAC is based on a 2D TSE sequence.”
Fat and water magnetic resonance imaging
Bley, T. A., Wieben, O., François, C. J., Brittain, J. H., & Reeder, S. B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21895 · Cited by 372 · cited 1×
“water-only and fat-only image reconstructions.(50,60) Images may be reconstructed with and without fat suppression.”
BackgroundFast and quiet MRI using a swept radiofrequency
Idiyatullin, D., Corum, C., Park, J.-Y., & Garwood, M. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.05.014 · Cited by 353
A multispectral three‐dimensional acquisition technique for imaging near metal implants
Koch, K. M., Lorbiecki, J. E., Hinks, R. S., & King, K. F. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21856 · Cited by 269
Stradiotti, P., Curti, A., Castellazzi, G., & Zerbi, A. (2009) · European Spine Journal · doi:10.1007/s00586-009-0998-5 · Cited by 241
Imaging near metal with a MAVRIC‐SEMAC hybrid
Koch, K. M., Brau, A. C., Chen, W., Gold, G. E., Hargreaves, B. A., Koff, M., McKinnon, G. C., Potter, H. G., & King, K. F. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22523 · Cited by 230 · cited 5×
“Siemens (Erlangen, Germany) calls its dedicated MARS techniques “WARP” (conventional MARS techniques plus VAT) and “advanced WARP” (WARP plus SEMAC) (in alphabetic order).(25,69,70,72) The efficacy of these advanced metal artifact reduction techniques with respect to artifact reduction as compared to conventional sequ…”
BackgroundMethodInfluential
Cited by
MRI in traumatic spinal cord injury: from clinical assessment to neuroimaging biomarkers
Freund, P., Seif, M., Weiskopf, N., Friston, K., Fehlings, M. G., Thompson, A. J., & Curt, A. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30138-3 · Cited by 222
Metadata
- Authors
- Jungmann, P. M., Agten, C. A., Pfirrmann, C. W., & Sutter, R.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2017-03-25
- Volume
- 46
- Issue
- 4
- Pages
- 972-991
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2603054283
- Cited by
- 227
- References
- 66
- FWCI
- 10.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.