Magnetic resonance imaging (MRI) is increasingly utilized as a radiation‐free alternative to computed tomography (CT) for the diagnosis and treatment planning of musculoskeletal pathologies. MR imaging of hard tissues such as cortical bone remains challenging due to their low proton density and short transverse relaxation times, rendering bone tissues as nonspecific low signal structures on MR images obtained from most sequences. Developments in MR image acquisition and post‐processing have opened the path for enhanced MR‐based bone visualization aiming to provide a CT‐like contrast and, as such, ease clinical interpretation. The purpose of this review is to provide an overview of studies comparing MR and CT imaging for diagnostic and treatment planning purposes in orthopedic care, with a special focus on selective bone visualization, bone segmentation, and three‐dimensional (3D) modeling. This review discusses conventional gradient‐echo derived techniques as well as dedicated short echo time acquisition techniques and post‐processing techniques, including the generation of synthetic CT, in the context of 3D and specific bone visualization. Based on the reviewed literature, it may be concluded that the recent developments in MRI‐based bone visualization are promising. MRI alone provides valuable information on both bone and soft tissues for a broad range of applications including diagnostics, 3D modeling, and treatment planning in multiple anatomical regions, including the skull, spine, shoulder, pelvis, and long bones. Level of Evidence: 3 Technical Efficacy: Stage 3
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lecture Notes in Computer Science 1205
(1999) · Industrial Robot: An International Journal · doi:10.1108/ir.1999.04926fae.001 · Cited by 38,662
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276 · cited 1×
“Alternatively, water-only images can be generated by acquiring a GRE sequence with specific echo times to perform a Dixon water–fat separation.(25,28,29,68,69)”
MethodWarner, D. O., Zaccariello, M. J., Katusic, S. K., Schroeder, D. R., Hanson, A. C., Schulte, P. J., Buenvenida, S. L., Gleich, S. J., Wilder, R. T., Sprung, J., et al. (2018) · Anesthesiology · doi:10.1097/aln.0000000000002232 · Cited by 598 · cited 1×
“The use of anesthesia is however not riskfree, especially on repeated occurrences.(113) In addition, uncontrolled motion was seen in the spine,(36) and the jaw,(53) and is common in clinical care of the shoulder, weakening the diagnostic power of MRI.”
BackgroundMandl, P., Navarro-Compán, V, Terslev, L., Aegerter, P., van der Heijde, D., D'Agostino, M. A., Baraliakos, X., Pedersen, S. J., Jurik, A. G., Naredo, E., et al. (2015) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2014-206971 · Cited by 572
Abdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination
Rofsky, N. M., Lee, V. S., Laub, G., Pollack, M. A., Krinsky, G. A., Thomasson, D., Ambrosino, M. M., & Weinreb, J. C. (1999) · Radiology · doi:10.1148/radiology.212.3.r99se34876 · Cited by 538
A review of substitute CT generation for MRI-only radiation therapy
Edmund, J. M., & Nyholm, T. (2017) · Radiation Oncology · doi:10.1186/s13014-016-0747-y · Cited by 378
Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques
Hofmann, M., Pichler, B., Schölkopf, B., & Beyer, T. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-1007-7 · Cited by 343
Dual‐echo Dixon imaging with flexible choice of echo times
Eggers, H., Brendel, B., Duijndam, A., & Herigault, G. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22578 · Cited by 320 · cited 1×
“Alternatively, water-only images can be generated by acquiring a GRE sequence with specific echo times to perform a Dixon water–fat separation.(25,28,29,68,69)”
MethodA review on medical imaging synthesis using deep learning and its clinical applications
Wang, T., Lei, Y., Fu, Y., Wynne, J. F., Curran, W. J., Liu, T., & Yang, X. (2021) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.13121 · Cited by 279 · cited 1×
“The most promising sCT generation models are deep learning-based and rely on various network architectures, including UNet,(73) generative adversarial network,(74) and their derivatives.(75) The use of sCT images has already been reviewed multiple times for radiotherapy purposes and PET-MR but their use for orthopedic…”
BackgroundQualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone
Du, J., Carl, M., Bydder, M., Takahashi, A., Chung, C. B., & Bydder, G. M. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.09.013 · Cited by 263 · cited 2×
“An image with a CT-like contrast containing signal mainly in short T2 components can then be obtained by suppressing the long T2 signal.(72) However, the fast gradient switching between TR’s and the acquisition during the gradient ramp up (Fig.”
BackgroundMethod
Metadata
- Authors
- Florkow, M. C., Willemsen, K., Mascarenhas, V. V., Oei, E. H. G., van Stralen, M., & Seevinck, P. R.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2022-01-19
- Volume
- 56
- Issue
- 1
- Pages
- 11-34
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W4206781950
- Cited by
- 232
- References
- 73
- FWCI
- 21.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Resonance Imaging Versus Computed Tomography for Three‐Dimensional Bone Imaging of Musculoskeletal Pathologies: A Review. https://app.cochat.ai/papers/10.1002/jmri.28067
- The paper
- Florkow, M. C., Willemsen, K., Mascarenhas, V. V., Oei, E. H. G., van Stralen, M., & Seevinck, P. R. (2022). Magnetic Resonance Imaging Versus Computed Tomography for Three‐Dimensional Bone Imaging of Musculoskeletal Pathologies: A Review. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.28067
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.