CoChat

High‐resolution tandem mass spectra of 37‐67 kDa proteins

Speir, J. Paul, Senko, Michael W., Little, Daniel P., Loo, Joseph. A., McLafferty, Fred W. · 1995 · Journal of Mass Spectrometry
Cited by 86

The DOI matches its Crossref record.

Abstract

By dissociating noncovalent adducts with infrared radiation and minimizing ion charge density during measurement, Fourier‐transform mass spectrometry with electrospray ionization yields 160 000 resolving power for porcine albumin. Its molecular weight calculated from the published sequence is 66 740, but values found for two different samples are MW = 66 736 and 66 886. The spectrum of their mixture confirms this mass difference. Similar measurements of two Protein A (45 kDa) samples also give molecular weights in substantial disagreement with literature sequences. Tandem mass spectrometry gives partial sequence information that demonstrates errors in some of the reported sequences.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jms.1190300108

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 86

Metadata

Authors
Speir, J. P., Senko, M. W., Little, D. P., Loo, J. A., & McLafferty, F. W.
Venue
Journal of Mass Spectrometry
Publisher
Wiley
Published
1995-01
Volume
30
Issue
1
Pages
39-42
ISSN
  • 1076-5174 (ISSN-L)
  • 1096-9888
OpenAlex
W1968212571
Cited by
86
References
0
FWCI
7.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High‐resolution tandem mass spectra of 37‐67 kDa proteins. https://app.cochat.ai/papers/10.1002/jms.1190300108
The paper
Speir, J. P., Senko, M. W., Little, D. P., Loo, J. A., & McLafferty, F. W. (1995). High‐resolution tandem mass spectra of 37‐67 kDa proteins. Journal of Mass Spectrometry. https://doi.org/10.1002/jms.1190300108

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.