Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 261

The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.

Factors influencing the steroid profile in doping control analysis

Mareck, Ute, Geyer, Hans, Opfermann, Georg, Thevis, Mario, Schänzer, Wilhelm·2008·Journal of Mass Spectrometry

Abstract

Steroid profiling is one of the most versatile and informative screening tools for the detection of steroid abuse in sports drug testing. Concentrations and ratios of various endogenously produced steroidal hormones, their precursors and metabolites including testosterone (T), epitestosterone (E), dihydrotestosterone (DHT), androsterone (And), etiocholanolone (Etio), dehydroepiandrosterone (DHEA), 5α‐androstane‐3α,17β‐diol (Adiol), and 5β‐androstane‐3α,17β‐diol (Bdiol) as well as androstenedione, 6α‐OH‐androstenedione, 5β‐androstane‐3α,17α‐diol (17‐epi‐Bdiol), 5α‐androstane‐3α,17α‐diol (17‐epi‐Adiol), 3α,5‐cyclo‐5α‐androstan‐6ß‐ol‐17‐one (3α,5‐cyclo), 5α‐androstanedione (Adion), and 5β‐androstanedione (Bdion) add up to a steroid profile that is highly sensitive to applications of endogenous as well as synthetic anabolic steroids, masking agents, and bacterial activity. Hence, the knowledge of factors that do influence the steroid profile pattern is a central aspect, and pharmaceutical (application of endogenous steroids and various pharmaceutical preparations), technical (hydrolysis, derivatization, matrix), and biological (bacterial activities, enzyme side activities) issues are reviewed. Copyright © 2008 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jms.1457

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 261

Metadata

Authors
Mareck, U., Geyer, H., Opfermann, G., Thevis, M., & Schänzer, W.
Venue
Journal of Mass Spectrometry
Publisher
Wiley
Published
2008-06-20
Volume
43
Issue
7
Pages
877-891
ISSN
  • 1076-5174 (ISSN-L)
  • 1096-9888
OpenAlex
W2091500539
Cited by
261
References
47
FWCI
67.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.