CoChat

Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry

Bornø, Andreas, Foged, Lene, van Hall, Gerrit · 2014 · Journal of Mass Spectrometry
Cited by 60

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The present study describes a new liquid chromatography tandem mass spectrometry method for high‐throughput quantification of glucose and glycerol in human plasma using stable isotopically labeled internal standards and is suitable for simultaneous measurements of glucose and glycerol enrichments in connection to in vivo metabolic studies investigating glucose turnover and lipolytic rate. Moreover, in order to keep up with this new fast analysis, simple derivatization procedures have been developed. Prior to analysis, glucose and glycerol were derivatized using benzoyl chloride in order to form benzoylated derivatives via new simplified fast procedures. For glucose, two internal standards were evaluated, [U‐13 C 6]glucose and [U‐13 C 6, D 7]glucose, and for glycerol, [U‐13 C 3, D 8]glycerol was used. The method was validated by means of calibration curves, quality control samples, and plasma samples spiked with [6,6‐D 2]glucose, [U‐13 C 6]glucose, and [1,1,2,3,3‐D 5]glycerol in order to test accuracy, precision, and recovery of the method. Moreover, post preparative and freeze‐thaw sample stability were tested. The correlation of calibration curves for the glucose concentration were r2 = 0.9998 for [U‐13 C 6]glucose and r2 = 0.9996 for [U‐13 C 6, D 7]glucose, and r2 = 0.9995 for the glycerol concentration. Interday accuracy for glucose using [U‐13 C 6]glucose and glycerol determined in spiked plasma were respectively 103.5% and 106.0%, and the coefficients of variation were 2.0% and 9.7%, respectively. After derivatization, plasma samples were stable for at least 14 days. In conclusion, we have developed and validated a novel, accurate, and sensitive high‐throughput liquid chromatography tandem mass spectrometry method for simultaneous determination of glucose and glycerol concentrations and enrichment of infused tracers most commonly used in human metabolic kinetic studies. Copyright © 2014 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jms.3407

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Bornø, A., Foged, L., & van Hall, G.
Venue
Journal of Mass Spectrometry
Publisher
Wiley
Published
2014-09-29
Volume
49
Issue
10
Pages
980-988
ISSN
  • 1076-5174 (ISSN-L)
  • 1096-9888
OpenAlex
W1914256835
Cited by
60
References
4
FWCI
2.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.