The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Structural characterization of flavonol 3,7‐di‐O‐glycosides and determination of the glycosylation position by using negative ion electrospray ionization tandem mass spectrometry
Abstract
Flavonol 3,7‐di‐O‐glycosides were investigated by negative ion electrospray ionization tandem mass spectrometry using a quadrupole linear ion trap (LIT) mass spectrometer. The results indicate that the fragmentation behavior of flavonol 3,7‐di‐O‐glycosides is substantially different from that of their isomeric mono‐O‐diglycosides. In order to characterize a flavonoid as a flavonol 3,7‐di‐O‐glycoside, both [Y 30 − H]−• and [Y 0 − 2H]− ions should be present in [M − H]− product ion spectrum. The MS 3 product ion spectra of Y 30−, [Y 30 − H]−• and Y 70− ions generated from the [M − H]− ion provide sufficient structural information for the determination of glycosylation position. Furthermore, the glycosylation positions are determined by comparing the relative abundances of Y 30− and Y 70− ions and their specific fragmentation patterns with those of flavonol mono‐O‐glycosides. In addition, a [Y 30 − H]−• ion formed by the homolytic cleavage of 3‐O glycosidic bond with high abundance points to 3‐O glycosylation, while a [Y 0 − 2H]− ion formed by the elimination of the two sugar residues is consistent with glycosylation at both the 3‐O and 7‐O positions. Investigation of negative ion ESI‐MS 2 and MS 3 spectra of flavonol O‐glycosides allows their rapid characterization as flavonol 3,7‐di‐O‐glycoside and their differentiation from isomeric mono‐O‐diglycosides, and also enables their direct analysis in crude plant extracts. Copyright © 2006 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Structure-antioxidant activity relationships of flavonoids and phenolic acids
Rice-Evans, C. A., Miller, N. J., & Paganga, G. (1996) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(95)02227-9 · Cited by 9,085
Cited by
Structural characterization of flavonoid glycosides by multi‐stage mass spectrometry
Vukics, V., & Guttman, A. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20212 · Cited by 337
Rodríguez-Pérez, C., Quirantes-Piné, R., Fernández-Gutiérrez, A., & Segura-Carretero, A. (2015) · Industrial Crops and Products · doi:10.1016/j.indcrop.2015.01.002 · Cited by 278
van der Hooft, J. J. J., Vervoort, J., Bino, R. J., Beekwilder, J., & de Vos, R. C. H. (2011) · Analytical Chemistry · doi:10.1021/ac102546x · Cited by 99
Quality structural annotation for the metabolites of chlorogenic acid in rat
Liu, W., Li, W., Zhang, P., Gong, X., Tu, P., Tang, L., Li, J., & Song, Y. (2022) · Food Chemistry · doi:10.1016/j.foodchem.2022.132134 · Cited by 43
Metadata
- Authors
- Ablajan, K., Abliz, Z., Shang, X., He, J., Zhang, R., & Shi, J.
- Venue
- Journal of Mass Spectrometry
- Publisher
- Wiley
- Published
- 2006-01-23
- Volume
- 41
- Issue
- 3
- Pages
- 352-360
- ISSN
- 1076-5174 (ISSN-L)
- 1096-9888
- OpenAlex
- W2021906139
- Cited by
- 237
- References
- 1
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.