Frequency spectrum analysis of wrist motion for activities of daily living
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A frequency spectral analysis was performed on wrist motion data for 24 activities of daily living (ADLs). Wrist motion was measured using a triaxial electrogoniometer attached to the wrist using tape (for 12 subjects) and pins (for one subject). Results show that the average predominant frequency component of these ADLs was ∼ 1 Hz with 75% of the spectral energy <5 Hz. The taped‐on electrogoniometer, when compared with the pinned electrogoniometer, was adequate for calculating the predominant frequency componenet and spread of spectral data, but overestimated the magnitudes of the maximum spectral density and total area of the spectral curves. This discrepancy was largest for axial rotation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Also in [34], the authors perform a large spectral analysis of twenty four activities of daily living, showing that most of them involve wrist notion in a frequency range around 1 Hz, being the predominant frequency components between 0.48 and 2.47 Hz.”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [34]
In the citing paper
“Voluntary motions are typically considered to have a frequency spectra below 2 Hz [43, 44]”
From Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor (2019) · cites this paper as [43]
In the citing paper
“ET and PD frequencies are considered to be in the range of 4–12 and 4–6 Hz, respectively, while ADL tend to be in the range of 0–2 Hz (Mann et al., 1989; Wyne, 2005; Taheri et al., 2015).”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Mann et al., 1989
Citations
Cites
A guided tour of the fast Fourier transform
Bergland, G. D. (1969) · IEEE Spectrum · doi:10.1109/mspec.1969.5213896 · Cited by 673
Functional wrist motion: A biomechanical study
Palmer, A. K., Werner, F. W., Murphy, D., & Glisson, R. (1985) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(85)80246-x · Cited by 623
Self-citation
Research works printed but not linked: 1
- TongJJ WernerFW SomersetJH:Wrist joint motion simulator. In:Transactions of the Orthopedic Research Society New Orleans Louisiana 1986 p441
Cited by
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349
Tele-impedance: Teleoperation with impedance regulation using a body–machine interface
Ajoudani, A., Tsagarakis, N., & Bicchi, A. (2012) · The International Journal of Robotics Research · doi:10.1177/0278364912464668 · Cited by 276
The relationship between wrist position, grasp size, and grip strength
O'Driscoll, S. W., Horii, E., Ness, R., Cahalan, T. D., Richards, R. R., & An, K.-N. (1992) · The Journal of Hand Surgery · doi:10.1016/0363-5023(92)90136-d · Cited by 266
Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data
Gallego, J., Rocon, E., Roa, J. O., Moreno, J., & Pons, J. L. (2010) · Sensors · doi:10.3390/s100302129 · Cited by 107
Characteristics of hand motion of eye surgeons
Riviere, C. N., Rader, R. S., & Khosla, P. K. (2002) · Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136) · doi:10.1109/iembs.1997.757046 · Cited by 98
Metadata
- Authors
- Mann, K. A., Wernere, F. W., & Palmer, A. K.
- Affiliations
- State University of New York (US)
- Corresponding author
- Wernere, Frederick W.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1989-03
- Volume
- 7
- Issue
- 2
- Pages
- 304-306
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2111421398
- Cited by
- 107
- References
- 2
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 3 · 2023: 4 · 2022: 5 · 2021: 4 · 2020: 7 · 2019: 4 · 2018: 2 · 2017: 5 · 2016: 9 · 2015: 4 · 2014: 5 · 2013: 7 · 2012: 3
- FWCI
- 0.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Orthopaedic Research® (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Surgery › Orthopedic Surgery and Rehabilitation
- Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
- Keywords
- wrist kinematics, activities of daily living, frequency spectrum analysis, electrogoniometer, power spectrum, axial rotation
- MeSH terms
- Activities of Daily Living, Humans, Movement, Spectrum Analysis, Wrist Joint
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Frequency spectrum analysis of wrist motion for activities of daily living. https://app.cochat.ai/papers/10.1002/jor.1100070219
- The paper
- Mann, K. A., Wernere, F. W., & Palmer, A. K. (1989). Frequency spectrum analysis of wrist motion for activities of daily living. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100070219
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.