Frequency spectrum analysis of wrist motion for activities of daily living
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A frequency spectral analysis was performed on wrist motion data for 24 activities of daily living (ADLs). Wrist motion was measured using a triaxial electrogoniometer attached to the wrist using tape (for 12 subjects) and pins (for one subject). Results show that the average predominant frequency component of these ADLs was ∼ 1 Hz with 75% of the spectral energy <5 Hz. The taped‐on electrogoniometer, when compared with the pinned electrogoniometer, was adequate for calculating the predominant frequency componenet and spread of spectral data, but overestimated the magnitudes of the maximum spectral density and total area of the spectral curves. This discrepancy was largest for axial rotation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Also in [34], the authors perform a large spectral analysis of twenty four activities of daily living, showing that most of them involve wrist notion in a frequency range around 1 Hz, being the predominant frequency components between 0.48 and 2.47 Hz.”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [34]
In the citing paper
“Voluntary motions are typically considered to have a frequency spectra below 2 Hz [43, 44]”
From Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor (2019) · cites this paper as [43]
In the citing paper
“ET and PD frequencies are considered to be in the range of 4–12 and 4–6 Hz, respectively, while ADL tend to be in the range of 0–2 Hz (Mann et al., 1989; Wyne, 2005; Taheri et al., 2015).”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Mann et al., 1989
Citations
Cites
A guided tour of the fast Fourier transform
Bergland, G. D. (1969) · IEEE Spectrum · doi:10.1109/mspec.1969.5213896 · Cited by 673
Functional wrist motion: A biomechanical study
Palmer, A. K., Werner, F. W., Murphy, D., & Glisson, R. (1985) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(85)80246-x · Cited by 623
Self-citation
Research works printed but not linked: 1
- TongJJ WernerFW SomersetJH:Wrist joint motion simulator. In:Transactions of the Orthopedic Research Society New Orleans Louisiana 1986 p441
Cited by
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349
Tele-impedance: Teleoperation with impedance regulation using a body–machine interface
Ajoudani, A., Tsagarakis, N., & Bicchi, A. (2012) · The International Journal of Robotics Research · doi:10.1177/0278364912464668 · Cited by 276
The relationship between wrist position, grasp size, and grip strength
O'Driscoll, S. W., Horii, E., Ness, R., Cahalan, T. D., Richards, R. R., & An, K.-N. (1992) · The Journal of Hand Surgery · doi:10.1016/0363-5023(92)90136-d · Cited by 266
Multijoint dynamics and postural stability of the human arm
Perreault, E. J., Kirsch, R. F., & Crago, P. E. (2004) · Experimental Brain Research · doi:10.1007/s00221-004-1864-7 · Cited by 182
Effects of voluntary force generation on the elastic components of endpoint stiffness
Perreault, E., Kirsch, R., & Crago, P. (2001) · Experimental Brain Research · doi:10.1007/s002210100880 · Cited by 158
Voluntary Control of Static Endpoint Stiffness During Force Regulation Tasks
Perreault, E. J., Kirsch, R. F., & Crago, P. E. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.87.6.2808 · Cited by 128
Design of Shape Memory Alloy-Based Soft Wearable Robot for Assisting Wrist Motion
Jeong, J., Yasir, I. B., Han, J., Park, C. H., Bok, S., & Kyung, K. (2019) · Applied Sciences · doi:10.3390/app9194025 · Cited by 111
Werner, F. W., Palmer, A. K., Somerset, J. H., Tong, J. J., Gillison, D. B., Fortino, M. D., & Short, W. H. (1996) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100140420 · Cited by 108
Self-citationReal-Time Estimation of Pathological Tremor Parameters from Gyroscope Data
Gallego, J., Rocon, E., Roa, J. O., Moreno, J., & Pons, J. L. (2010) · Sensors · doi:10.3390/s100302129 · Cited by 107
Characteristics of hand motion of eye surgeons
Riviere, C. N., Rader, R. S., & Khosla, P. K. (2002) · Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136) · doi:10.1109/iembs.1997.757046 · Cited by 98
Effects of age and disability on tracking tasks with a computer mouse: accuracy and linearity.
Riviere, C. N., & Thakor, N. V. (1996) · PubMed · Cited by 90
Ajoudani, A., Fang, C., Tsagarakis, N. G., & Bicchi, A. (2017) · The International Journal of Robotics Research · doi:10.1177/0278364917744035 · Cited by 89
Wearable inertial mouse for children with physical and cognitive impairments
Raya, R., Roa, J. O., Rocón, E., Ceres, R., & Pons, J. L. (2010) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2010.04.019 · Cited by 84
A neuroprosthesis for tremor management through the control of muscle co-contraction
Gallego, J. Á., Rocon, E., Belda-Lois, J. M., & Pons, J. L. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-36 · Cited by 81
“The estimation of voluntary movement relied on the fact that tremors occur at a higher frequency (in the 3– 12 Hz band [10]) than that employed to perform the ADL (below 2 Hz [43]).”
MethodTatinati, S., Veluvolu, K. C., & Ang, W. T. (2015) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2014.2381495 · Cited by 77
Wrist Assisting Soft Wearable Robot With Stretchable Coolant Vessel Integrated SMA Muscle
Jeong, J., Hyeon, K., Han, J., Park, C. H., Ahn, S. Y., Bok, S., & Kyung, K. (2021) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2021.3078472 · Cited by 77
Radwin, R. G., & LIN, M. L. (1993) · Ergonomics · doi:10.1080/00140139308967895 · Cited by 77
On the Orientation Error of IMU: Investigating Static and Dynamic Accuracy Targeting Human Motion
Ricci, L., Taffoni, F., & Formica, D. (2016) · PLOS ONE · doi:10.1371/journal.pone.0161940 · Cited by 75
Empowering and Assisting Natural Human Mobility: The Simbiosis Walker
Frizera, A., Ceres, R., Rocón, E., & Pons, J. L. (2011) · International Journal of Advanced Robotic Systems · doi:10.5772/10666 · Cited by 71
Johnson, P. W., Jonsson, P., & Hagberg, M. (2002) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00031-7 · Cited by 69
Heart Rate Detection Using Microsoft Kinect: Validation and Comparison to Wearable Devices
Gambi, E., Agostinelli, A., Belli, A., Burattini, L., Cippitelli, E., Fioretti, S., Pierleoni, P., Ricciuti, M., Sbrollini, A., & Spinsante, S. (2017) · Sensors · doi:10.3390/s17081776 · Cited by 67
GPS/BDS short-term ISB modelling and prediction
Jiang, N., Xu, Y. L., Xu, T., Xu, G., Sun, Z., & Schuh, H. (2016) · GPS Solutions · doi:10.1007/s10291-015-0513-x · Cited by 66
Gillard, D. M., Cameron, T., Prochazka, A., & Gauthier, M. J. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788474 · Cited by 61
Soft Wearable Rehabilitation Robots with Artificial Muscles based on Smart Materials: A Review
Gonzalez-Vazquez, A., García, L., Kilby, J., & McNair, P. J. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200159 · Cited by 55
Adaptive Suppression of Severe Pathological Tremor by Torque Estimation Method
Taheri, B., Case, D., & Richer, E. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2317948 · Cited by 53
“The intentional motion torque, τI , contains components in the frequency range of 0–2 Hz, typical for the majority of daily tasks [10], [30], [39].”
BackgroundVoluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression
Herrnstadt, G., & Menon, C. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00029 · Cited by 49
“ET and PD frequencies are considered to be in the range of 4–12 and 4–6 Hz, respectively, while ADL tend to be in the range of 0–2 Hz (Mann et al., 1989; Wyne, 2005; Taheri et al., 2015).”
BackgroundUpper-Limb Robotic Rehabilitation Exoskeleton: Tremor Suppression
Pons, J. L., Rocón, E., Ruiz-Olaya, A. F., & Moreno, J. C. (2007) · doi:10.5772/5175 · Cited by 49
Extraction of user's navigation commands from upper body force interaction in walker assisted gait
Frizera Neto, A., Gallego, J. A., Rocon, E., Pons, J. L., & Ceres, R. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-37 · Cited by 48
Quantifying the importance of high frequency components on the amplitude of physiological tremor
Carignan, B., Daneault, J., & Duval, C. (2009) · Experimental Brain Research · doi:10.1007/s00221-009-2132-7 · Cited by 45
Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2859793 · Cited by 42
Vib-bracelet: a passive absorber for attenuating forearm tremor
Buki, E., Katz, R., Zacksenhouse, M., & Schlesinger, I. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-017-1742-7 · Cited by 42
Proportional Myoelectric Control of a Multifunction Upper-limb Prosthesis
Fougner, A. L. (2007) · NVA (Nasjonalt vitenarkiv) · Cited by 41
Three-dimensional accuracy assessment of eye surgeons
Hotraphinyo, L. F., & Riviere, C. N. (2005) · 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2001.1019574 · Cited by 40
Tremor-Suppression Orthoses for the Upper Limb: Current Developments and Future Challenges
Nguyen, S. H., & Luu, T. P. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.622535 · Cited by 40
Phase-Lead Stabilization of Force-Projecting Master-Slave Systems With a New Sliding Mode Filter
Kikuuwe, R., Kanaoka, K., Kumon, T., & Yamamoto, M. (2015) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2015.2404893 · Cited by 38
Proximal-distal differences in movement smoothness reflect differences in biomechanics
Salmond, L. H., Davidson, A. D., & Charles, S. K. (2016) · Journal of Neurophysiology · doi:10.1152/jn.00712.2015 · Cited by 37
Tatinati, S., Nazarpour, K., Ang, W. T., & Veluvolu, K. C. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2597119 · Cited by 36
A Surgeon-Robot Shared Control for Ergonomic Pedicle Screw Fixation
Lauretti, C., Cordella, F., Tamantini, C., Gentile, C., di Luzio, F. S., & Zollo, L. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.2972892 · Cited by 33
Smart Walkers: Advanced Robotic Human Walking-Aid Systems
Frizera, A., Elías, A., Cifuentes, C. A., Rodríguez, C., Bastos-Filho, T., & Carelli, R. O. (2015) · Springer tracts in advanced robotics · doi:10.1007/978-3-319-12922-8_4 · Cited by 32
Chammas, P.-E., Hadouiri, N., Chammas, M., Ramos‐Pascual, S., Stirling, P., Nover, L., & Klouche, S. (2022) · Orthopaedics & Traumatology Surgery & Research · doi:10.1016/j.otsr.2022.103373 · Cited by 32
Herrnstadt, G., McKeown, M. J., & Menon, C. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0484-1 · Cited by 30
Fundamental Principles of Tremor Propagation in the Upper Limb
Davidson, A. D., & Charles, S. K. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1765-5 · Cited by 29
Kikuuwe, R., Yamamoto, T., & Fujimoto, H. (2008) · IEEE Transactions on Systems Man and Cybernetics - Part A Systems and Humans · doi:10.1109/tsmca.2008.923085 · Cited by 28
Identification of activities of daily living in tremorous patients using inertial sensors
Serrano, J. I., Lambrecht, S., del Castillo, M. D., Romero, J. P., Benito‐León, J., & Rocón, E. (2017) · Expert Systems with Applications · doi:10.1016/j.eswa.2017.04.032 · Cited by 26
Adaptive notch filter for pathological tremor suppression using permanent magnet linear motor
Zamanian, A. H., & Richer, E. (2019) · Mechatronics · doi:10.1016/j.mechatronics.2019.102273 · Cited by 22
Greco, C., Weerakkody, T. H., Cichella, V., Pagnotta, L., & Lamuta, C. (2023) · Robotics · doi:10.3390/robotics12010027 · Cited by 22
Movement preferences of the wrist and forearm during activities of daily living
Anderton, W., Tew, S., Ferguson, S., Hernandez, J., & Charles, S. K. (2022) · Journal of Hand Therapy · doi:10.1016/j.jht.2022.07.003 · Cited by 20
Howcroft, J., Fehlings, D. L., Zabjek, K., Fay, L., LIANG, J., & Biddiss, E. A. (2011) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.2011.04078.x · Cited by 20
Wade, E., Chen, C., & Winstein, C. J. (2013) · Neurorehabilitation and neural repair · doi:10.1177/1545968313505911 · Cited by 18
Lee, J., Kim, H., & Yang, W. (2021) · Sensors · doi:10.3390/s21238073 · Cited by 18
Postural arm control following cervical spinal cord injury
Perreault, E. J., Crago, P. E., & Kirsch, R. F. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2001.1000117 · Cited by 18
Entropy-based analysis of rhythmic tapping for the quantitative assessment of cerebellar ataxia
Nguyen, K. D., Pathirana, P. N., Horne, M. K., Power, L., & Szmulewicz, D. J. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.101916 · Cited by 17
Lambrecht, S., Gallego, J. A., Rocon, E., & Pons, J. L. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00221 · Cited by 16
Simultaneous Estimations of Joint Angle and Torque in Interactions with Environments using EMG
Kim, D.-W., Koh, K., Oppizzi, G., Baghi, R., Lo, L., Zhang, C., & Zhang, L.-Q. (2020) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra40945.2020.9197441 · Cited by 16
Cyberthosis: Rehabilitation Robotics With Controlled Electrical Muscle Stimulation
Métrailler, P., Brodard, R., Stauffer, Y., Clavel, R., & Frischknecht, R. (2007) · doi:10.5772/5167 · Cited by 16
Estimation of instantaneous tremor parameters for FES-based tremor suppression
Gallego, J. Á., Rocón, E., & Pons, J. L. (2010) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2010.5509663 · Cited by 15
VibEye: Vibration-Mediated Object Recognition for Tangible Interactive Applications
Oh, S., Yun, G., Park, C., Kim, J., & Choi, S. (2019) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3290605.3300906 · Cited by 15
Lee, S., Nam, G.-J., Chae, J., Kim, H., & Drake, A. J. (2005) · IEEE Transactions on Very Large Scale Integration (VLSI) Systems · doi:10.1109/tvlsi.2005.859473 · Cited by 15
Takeya, M., Kawamura, Y., & Katsura, S. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2512233 · Cited by 15
Kim, D.-W., Koh, K., Oppizzi, G., Baghi, R., Lo, L., Zhang, C., & Zhang, L.-Q. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3134204 · Cited by 14
Tremor Suppression With Mechanical Vibration Stimulation
Liu, W., Kai, T., & Kiguchi, K. (2020) · IEEE Access · doi:10.1109/access.2020.3045023 · Cited by 13
“5 Hz [43], the activities of daily living and ET is separated according to the frequency of motion data in the proposed method to maintain the voluntary movement and suppress only the ET.”
MethodMescollotto, F. F., Silva, L. C. C. B., Sato, T. D. O., & Coury, H. J. C. G. (2013) · Brazilian Journal of Physical Therapy · doi:10.1590/s1413-35552012005000067 · Cited by 12
Zhang, Y., Yi, Q., Yi, S., Zhang, X., & Li, J. (2024) · Behaviour and Information Technology · doi:10.1080/0144929x.2024.2321933 · Cited by 12
Frizera, A. (2010) · e_Buah · Cited by 12
Lapresa, M., Tamantini, C., di Luzio, F. S., Ferlazzo, M., Sorrenti, G., Corpina, F., & Zollo, L. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3193313 · Cited by 11
mmTremor: Practical Tremor Monitoring for Parkinson's Disease and Essential Tremor in Daily Life
Hu, Q., Zhou, Y., Wang, J., Huang, Z., Li, G., Xu, Q., & Zhang, Q. (2025) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/3680207.3723488 · Cited by 10
System identification for FES-based tremor suppression
Çopur, E. H., Freeman, C. T., Chu, B., & Laila, D. S. (2015) · European Journal of Control · doi:10.1016/j.ejcon.2015.12.003 · Cited by 10
Measuring dynamic characteristics of the human arm in three dimensional space
Pierre, M. C., & Kirsch, R. F. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2002.1053425 · Cited by 10
Analysis of kinematic data in pathological tremor with the Hilbert-Huang transform
Gallego, J. Á., Rocón, E., Koutsou, A. D., & Pons, J. L. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910493 · Cited by 9
Real-Time Sensing of Upper Extremity Movement Diversity Using Kurtosis Implemented on a Smartwatch
Cornella-Barba, G., Okita, S., Li, Z., & Reinkensmeyer, D. J. (2024) · Sensors · doi:10.3390/s24165266 · Cited by 9
A bilateral wrist robotic system with compliant actuation for rehabilitation training
Hou, Z., Tong, Y., Shi, K., & Yu, H. (2025) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2025.105937 · Cited by 9
Kim, K., & Lee, J. (2012) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1458 · Cited by 9
An IMU-Based Wearable System for Automatic Pointing During Presentations
Sikeridis, D., & Antonakopoulos, T. A. (2016) · Image Processing & Communications · doi:10.1515/ipc-2016-0007 · Cited by 9
Gallego, J. A., Rocon, E., Roa, J. O., Moreno, J. C., Koutsou, A. D., & Pons, J. L. (2009) · Procedia Chemistry · doi:10.1016/j.proche.2009.07.304 · Cited by 8
Raya, R., Ceres, R., Roa, J. O., & Rocón, E. (2010) · ACM International Conference on Interaction Design and Children (IDC) · doi:10.1145/1810543.1810558 · Cited by 7
Kieliba, P., Veltink, P. H., Baldi, T. L., Prattichizzo, D., Santaera, G., Bicchi, A., Bianchi, M., & van Beijnum, B.-J. F. (2018) · IEEE-RAS International Conference on Humanoid Robots (Humanoids) · doi:10.1109/humanoids.2018.8624929 · Cited by 7
Frizera, A., Ceres, R., & Pons, J. L. (2011) · Revista Iberoamericana de Automática e Informática Industrial RIAI · doi:10.1016/s1697-7912(11)70028-0 · Cited by 6
Kincaid, C. J., Johnson, P. K., & Charles, S. K. (2023) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/acb159 · Cited by 6
Edmonds, B. P. R., & Trejos, A. L. (2020) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob49111.2020.9224459 · Cited by 6
ARMStick - An Intuitive Therapist Interface for Upper-Limb Rehabilitation Robots
Sommerhalder, M., Kurth, N., Song, J., & Riener, R. (2022) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr55369.2022.9896409 · Cited by 6
Ratschat, A. L., Martín-Rodríguez, R., Vardar, Y., Ribbers, G. M., & Marchal–Crespo, L. (2024) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob60516.2024.10719873 · Cited by 6
Smartwatch-based wrist tremor assessment in neurosurgical simulator training
Berger, L., Civilla, L., Dodier, P., Rössler, K., & Moscato, F. (2025) · Scientific Reports · doi:10.1038/s41598-025-08244-3 · Cited by 5
Sepehri, A., Tolley, M. T., & Morimoto, T. K. (2025) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr66766.2025.11062992 · Cited by 5
Efficient Steady-State Tissue Simulation for Surgical Robotics: A First-Order Position-Based Method
Tobin, S., Wu, Y., Liu, F., & Rucker, D. C. (2025) · International Symposium on Medical Robotics · doi:10.1109/ismr67322.2025.11025985 · Cited by 5
Isoelastic Distal Ulnar Head Prosthesis: An In Vitro Joint Simulator Study
Naidu, S. H., & Radin, A. (2009) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2008.11.031 · Cited by 5
Ricci, L., & Formica, D. (2014) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2014.6985480 · Cited by 4
Low-Force Kinesthetic Guidance for Accurate Positioning and Tracking
Kikuuwe, R., Yamamoto, T., & Fujimoto, H. (2006) · Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems · doi:10.1109/haptics.2006.168 · Cited by 4
Ergonomic Risk Assessment of a Manikin’s Wrist Movements - a Test Study in Manual Assembly
Keyvani, A., Högberg, D., Hanson, L. Å., Lämkull, D., Delfs, N., Rhén, I.-M., & Örtengren, R. (2013) · Cited by 4
Raji, A., DiNunzio, S., Whitmell, A., Márquez-Chin, C., & Popović, M. R. (2025) · BioMedical Engineering OnLine · doi:10.1186/s12938-025-01384-7 · Cited by 4
Raya, R., Ceres, R., Rocón, E., & Pons, J. L. (2009) · Procedia Chemistry · doi:10.1016/j.proche.2009.07.181 · Cited by 4
First-Order Position-Based Simulation of Deformable Concentric-Tube Robots Interacting with Tissue
Tobin, S., Wu, Y., Liu, F., & Rucker, D. C. (2026) · Journal of Medical Robotics Research · doi:10.1142/s2424905x26400039 · Cited by 3
An IMU-based Wearable Presentation Pointing Device
Antonakopoulos, T. A., & Sikeridis, D. (2016) · IEICE Proceedings Series · Cited by 3
Low-Force Kinesthetic Guidance for Accurate Positioning and Tracking
Kikuuwe, R., Yamamoto, T., & Fujimoto, H. (2006) · Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems · doi:10.1109/haptic.2006.1627114 · Cited by 2
Gonzalez-Vazquez, A., García, L., & Kilby, J. (2023) · Smart Materials and Structures · doi:10.1088/1361-665x/acded6 · Cited by 2
GNSS inter-system bias estimation, modeling, and prediction
Jiang, N. (2019) · DepositOnce · doi:10.14279/depositonce-8503 · Cited by 2
A Biomechanical Model for Pathological Tremor Suppression
Lois, J. M. B., Horno, S. M.-D., Bermejo, I., Castillo, A., & Sancho, J. (2013) · Biosystems & biorobotics · doi:10.1007/978-3-642-34546-3_110 · Cited by 1
Dead Zone Bilateral Control for High Performance Robotic Teleoperation
Kota, R., Dills, P., Reardon, G., Elwin, M. L., & Colgate, J. E. (2026) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2026.3675931 · Cited by 1
Repetitive control based tremor suppression using electrical stimulation
Çopur, E. H., Freeman, C. T., Chu, B., & Laila, D. S. (2014) · UKACC International Conference on Control · doi:10.1109/control.2014.6915205 · Cited by 1
Cho, J., Park, H., & Kim, J. (2020) · Journal of the Korean Society for Precision Engineering · doi:10.7736/jkspe.020.020 · Cited by 1
Wade, E., & Fan, T.-W. J. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696170 · Cited by 1
Metadata
- Authors
- Mann, K. A., Wernere, F. W., & Palmer, A. K.
- Affiliations
- State University of New York (US)
- Corresponding author
- Wernere, Frederick W.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1989-03
- Volume
- 7
- Issue
- 2
- Pages
- 304-306
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2111421398
- Cited by
- 107
- References
- 2
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 3 · 2023: 4 · 2022: 5 · 2021: 4 · 2020: 7 · 2019: 4 · 2018: 2 · 2017: 5 · 2016: 9 · 2015: 4 · 2014: 5 · 2013: 7 · 2012: 3
- FWCI
- 0.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Orthopaedic Research® (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Surgery › Orthopedic Surgery and Rehabilitation
- Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
- Keywords
- wrist kinematics, activities of daily living, frequency spectrum analysis, electrogoniometer, power spectrum, axial rotation
- MeSH terms
- Activities of Daily Living, Humans, Movement, Spectrum Analysis, Wrist Joint
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.