Frequency spectrum analysis of wrist motion for activities of daily living
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A frequency spectral analysis was performed on wrist motion data for 24 activities of daily living (ADLs). Wrist motion was measured using a triaxial electrogoniometer attached to the wrist using tape (for 12 subjects) and pins (for one subject). Results show that the average predominant frequency component of these ADLs was ∼ 1 Hz with 75% of the spectral energy <5 Hz. The taped‐on electrogoniometer, when compared with the pinned electrogoniometer, was adequate for calculating the predominant frequency componenet and spread of spectral data, but overestimated the magnitudes of the maximum spectral density and total area of the spectral curves. This discrepancy was largest for axial rotation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Also in [34], the authors perform a large spectral analysis of twenty four activities of daily living, showing that most of them involve wrist notion in a frequency range around 1 Hz, being the predominant frequency components between 0.48 and 2.47 Hz.”
From Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data (2010) · cites this paper as [34]
In the citing paper
“Voluntary motions are typically considered to have a frequency spectra below 2 Hz [43, 44]”
From Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor (2019) · cites this paper as [43]
In the citing paper
“ET and PD frequencies are considered to be in the range of 4–12 and 4–6 Hz, respectively, while ADL tend to be in the range of 0–2 Hz (Mann et al., 1989; Wyne, 2005; Taheri et al., 2015).”
From Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression (2016) · cites this paper as Mann et al., 1989
Citations
Cites
A guided tour of the fast Fourier transform
Bergland, G. D. (1969) · IEEE Spectrum · doi:10.1109/mspec.1969.5213896 · Cited by 673
Functional wrist motion: A biomechanical study
Palmer, A. K., Werner, F. W., Murphy, D., & Glisson, R. (1985) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(85)80246-x · Cited by 623
Self-citation
Research works printed but not linked: 1
- TongJJ WernerFW SomersetJH:Wrist joint motion simulator. In:Transactions of the Orthopedic Research Society New Orleans Louisiana 1986 p441
Cited by
Items 101–122 of 122
Chammas, P.-E., Hadouiri, N., Chammas, M., Ramos‐Pascual, S., Stirling, P., Nover, L., & Klouche, S. (2022) · Revue de Chirurgie Orthopédique et Traumatologique · doi:10.1016/j.rcot.2022.07.012 · Cited by 1
Characterization of Smoothness in Wrist Rotations
Salmond, L. H. (2014) · ScholarsArchive (Brigham Young University) · Cited by 1
Modélisation musculo-quelettique de la main et du poignet en utilisant des radiographies biplanes
Durand, S. (2020) · theses.fr (ABES) · doi:10.70675/87eb9fbbzd625z4f27z8ccczc8598ac9757f · Cited by 1
Design and Validation of a Smart Brace; Wearable Technology for Carpal Tunnel Syndrome
Piper, B. (2017) · The Atrium (University of Guelph) · Cited by 1
DipMe: Haptic Recognition of Granular Media for Tangible Interactive ApplicationsPreprint
Wang, X., Zhang, S., Zhao, Z., Zhu, L., & Song, A. (2024) · arXiv (Cornell University) · doi:10.48550/arxiv.2411.08641 · Cited by 1
System identification of the reflex contribution to human ankle dynamics
Perreault, E. J. (1992) · doi:10.82308/24612 · Cited by 1
Widjaja, F. (2011) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/42882
Voluntary Driven, Velocity Controlled Tremor Suppression
Herrnstadt, G. (2017) · Summit (Simon Fraser University)
Spectral Analysis: a New Perspective for Mining Human Activity Data
Zhang, X. (2017) · eScholarship (California Digital Library)
A neuroprothesis for tremor management
Abella, G., & Álvaro, J. C. (2013) · DIGITAL.CSIC (Spanish National Research Council (CSIC))
Gormez, M. A., Makowski, N. S., Crago, P. E., & Fu, M. J. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae57da
A Task-Agnostic Control Strategy for Dynamic Assistance with Pneumatically Actuated Soft ExosuitsPreprint
Sepehri, A., Huang, Z., CALLAFON, R. A. D., Tolley, M. T., & Morimoto, T. K. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2608.18364
Design and control of artificial muscles for robotic applications
Weerakkody, T. H. (2024) · Iowa Research Online (The University of Iowa) · doi:10.25820/etd.007599
Treatment of wrist deformities in children with arthrogryposis multiplex congenita
Kochenova, E. A., Agranovich, O. Е., & Savina, M. V. (2016) · Pediatric Traumatology Orthopaedics and Reconstructive Surgery · doi:10.17816/ptors4126-36
Estimering av spedbarns bevegelser ut fra videodata
Nesset, S. A. (2008) · NVA (Nasjonalt vitenarkiv)
Raji, A., Márquez-Chin, C., Gopaul, U., & Popović, M. R. (2025) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr66766.2025.11063009
Haptic synthesis of dynamically deformable materials
Gosline, A. H. (2009) · eScholarship@McGill (McGill) · doi:10.82308/41998
Capteurs intelligents : quelles méthodologies pour la fusion de données embarquées ?
Valade, A. (2017) · theses.fr (ABES) · doi:10.70675/a31d8414z39bfz4d9az9cb2zce4e04dad9d7
Shi, F., Tan, J., Wang, D., Wang, X., Li, H., Huang, X., & Jiang, Z. (2026) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2026.3685917
Metadata
- Authors
- Mann, K. A., Wernere, F. W., & Palmer, A. K.
- Affiliations
- State University of New York (US)
- Corresponding author
- Wernere, Frederick W.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1989-03
- Volume
- 7
- Issue
- 2
- Pages
- 304-306
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2111421398
- Cited by
- 107
- References
- 2
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 3 · 2023: 4 · 2022: 5 · 2021: 4 · 2020: 7 · 2019: 4 · 2018: 2 · 2017: 5 · 2016: 9 · 2015: 4 · 2014: 5 · 2013: 7 · 2012: 3
- FWCI
- 0.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Orthopaedic Research® (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Surgery › Orthopedic Surgery and Rehabilitation
- Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
- Keywords
- wrist kinematics, activities of daily living, frequency spectrum analysis, electrogoniometer, power spectrum, axial rotation
- MeSH terms
- Activities of Daily Living, Humans, Movement, Spectrum Analysis, Wrist Joint
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.