CoChat

The effects of initial end contact on medial collateral ligament healing: A morphological and biomechanical study in a rabbit model

Chimich, D., Frank, C., Shrive, N., Dougall, H., Bray, R. · 1991 · Journal of Orthopaedic Research
Cited by 98

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

In this investigation, the effect of initial end contact on medial collateral ligament (MCL) healing was studied in the rabbit model. Sixty‐eight 1‐year‐old New Zealand white rabbits were separated into two groups. In one group, a 4 mm saggital Z‐plasty was performed in the right MCL midsubstance (contact group), and in the other group, an analogous 4 mm midsubstance segment was removed (gap group). Left knees were unoperated to serve as internal contralateral MCL controls. Animals had unrestricted cage activity until sacrifice in groups of eight at 3, 6, 14, and 40 weeks postoperatively. Early results demonstrated that contact and gap injuries healed with what appeared to be scar tissue both morphologically and biomechanically. In both groups, laxities recovered to their contralateral values within 6 weeks and biomechanical viscoelastic behaviors recovered to 68–92% of contralaterals by 14–40 weeks. Despite these similarities, contacts showed morphological and biomechanical evidence of improved healing over gaps. Contact scars remodeled more quickly, recovered laxity more quickly, and were generally colser to contralaterals than gaps in terms of their structural strength, stiffness, and material behaviors, after 40 weeks of healing. With the exception of appearances and failure stress, all measured properties of contact healing MCLs were statistically indistinguishable from contralateral MCLs at 40 weeks of healing. These advantages of contact healing in this model support speculations that there are differences in the early rate and possibly in the later quality of ligament healing when cut rabbit MCL ends are in proximity. Longer‐term studies to define end points and mechanisms of healing are required.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jor.1100090106

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 98

Metadata

Authors
Chimich, D., Frank, C., Shrive, N., Dougall, H., & Bray, R.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
1991-01
Volume
9
Issue
1
Pages
37-47
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W2045103340
Cited by
98
References
2
FWCI
4.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effects of initial end contact on medial collateral ligament healing: A morphological and biomechanical study in a rabbit model. https://app.cochat.ai/papers/10.1002/jor.1100090106
The paper
Chimich, D., Frank, C., Shrive, N., Dougall, H., & Bray, R. (1991). The effects of initial end contact on medial collateral ligament healing: A morphological and biomechanical study in a rabbit model. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100090106

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.