CoChat

Telemeterized in vivo hip joint force data: A report on two patients after total hip surgery

Kotzar, G. M., Davy, D. T., Goldberg, V. M., Heiple, K. G., Berilla, J., Heiple, K. G., Brown, R. H., Burstein, A. H. · 1991 · Journal of Orthopaedic Research
Cited by 190

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Two telemeterized femoral components were implanted in two patients as part of normal total hip replacement procedures. The two components were instrumented to measure the three force components directed along: (a) the neck axis, (b) transverse to the neck axis and in the plane of the prosthesis, and (c) transverse to the neck axis and perpendicular to the plane of the prosthesis. Data were collected at multiple sessions during the early postoperative period for a number of standard activities, including gait, stair climbing, rising from a chair, single leg stance, double leg stance, ipsilateral and contralateral straight leg lifts while supine, ipsilateral flexion and extension while standing, and ipsilateral abduction while standing and lying on the contralateral side. These data are summarized and compared with the published results from analytic studies and with the results from previous studies using instrumented femoral components. Peak loads for gait during the period of study were roughly 2.7 body weights (BW) when the patients walked at their normal pace. Contact forces at the hip during stationary single leg stance approximated the peak loads during gait with values ranging from 2.1 to 2.8 BW. The highest forces recorded reached values approaching 5.5 BW and occurred during periods of instability while the patient engaged in stationary single leg stance. Our in vivo data indicate that forces generated during the above activities increase in magnitude quite rapidly during the early postoperative period and that during this period the patients have the ability to perform the activities of daily living without generating the high amplitude joint contact forces suggested by the results of dynamic studies. Joint contact forces during gait were found to depend on speed, but the high absolute magnitudes predicted by model studies were not supported by the in vivo data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jor.1100090502

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 190

Metadata

Authors
Kotzar, G. M., Davy, D. T., Goldberg, V. M., Heiple, K. G., Berilla, J., Heiple, K. G., Brown, R. H., & Burstein, A. H.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
1991-09
Volume
9
Issue
5
Pages
621-633
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W1978427781
Cited by
190
References
12
FWCI
1.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.