Implantable microelectromechanical sensors for diagnostic monitoring and post‐surgical prediction of bone fracture healing
Open accessThe DOI matches its Crossref record.
Abstract
The relationship between modern clinical diagnostic data, such as from radiographs or computed tomography, and the temporal biomechanical integrity of bone fracture healing has not been well‐established. A diagnostic tool that could quantitatively describe the biomechanical stability of the fracture site in order to predict the course of healing would represent a paradigm shift in the way fracture healing is evaluated. This paper describes the development and evaluation of a wireless, biocompatible, implantable, microelectromechanical system (bioMEMS) sensor, and its implementation in a large animal (ovine) model, that utilized both normal and delayed healing variants. The in vivo data indicated that the bioMEMS sensor was capable of detecting statistically significant differences (p‐value <0.04) between the two fracture healing groups as early as 21 days post‐fracture. In addition, post‐sacrifice micro‐computed tomography, and histology data demonstrated that the two model variants represented significantly different fracture healing outcomes, providing explicit supporting evidence that the sensor has the ability to predict differential healing cascades. These data verify that the bioMEMS sensor can be used as a diagnostic tool for detecting the in vivo course of fracture healing in the acute post‐treatment period. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:1439–1446, 2015.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A stretchable and biodegradable strain and pressure sensor for orthopaedic application
Boutry, C. M., Kaizawa, Y., Schroeder, B. C., Chortos, A., Legrand, A., Wang, Z., Chang, J., Fox, P., & Bao, Z. (2018) · Nature Electronics · doi:10.1038/s41928-018-0071-7 · Cited by 667
Stretchable and suturable fibre sensors for wireless monitoring of connective tissue strain
Lee, J., Ihle, S. J., Pellegrino, G. S., Kim, H., Yea, J., Jeon, C.-Y., Son, H.-C., Jin, C., Eberli, D., Schmid, F., et al. (2021) · Nature Electronics · doi:10.1038/s41928-021-00557-1 · Cited by 253
Dinh, T., Nguyen, T., Phan, H.-P., Nguyen, N.-T., Dao, D. V., & Bell, J. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112460 · Cited by 205
Continuous implant load monitoring to assess bone healing status-evidence from animal testing
Windolf, M., Varjas, V., Gehweiler, D., Schwyn, R., Arens, D., Constant, C., Zeiter, S., Richards, R. G., & Ernst, M. (2022) · Medicina · doi:10.3390/medicina58070858 · Cited by 63
Smart implants in fracture care – Only buzzword or real opportunity
Ernst, M., Richards, R. G., & Windolf, M. (2021) · Injury · doi:10.1016/j.injury.2020.09.026 · Cited by 50
Metadata
- Authors
- McGilvray, K. C., Unal, E., Troyer, K. L., Santoni, B. G., Palmer, R. H., Easley, J. T., Demir, H. V., & Puttlitz, C. M.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 2015-07-29
- Volume
- 33
- Issue
- 10
- Pages
- 1439-1446
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W1928038557
- Cited by
- 74
- References
- 0
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.