CoChat

Comparison of High‐Hydrostatic‐Pressure Decellularized Versus Freeze‐Thawed Porcine Menisci

Open access
Watanabe, Naoto, Mizuno, Mitsuru, Matsuda, Junpei, Nakamura, Naoko, Otabe, Koji, Katano, Hisako, Ozeki, Nobutake, Kohno, Yuji, Kimura, Tsuyoshi, Tsuji, Kunikazu, Koga, Hideyuki, Kishida, Akio, Sekiya, Ichiro · 2019 · Journal of Orthopaedic Research
Cited by 33

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The meniscus functions as a load distributor and secondary stabilizer in the knee, and the loss of the meniscus increases the risk of osteoarthritis. Freeze‐thawed menisci are used in clinical practice to replace defective menisci; however, the disadvantages of freeze‐thawed tissues include disease transmission and immune rejection. In this study, we decellularized menisci using high hydrostatic pressure (HHP) and compared the decellularized menisci with freeze‐thawed menisci. Porcine menisci were either pressurized at 1,000 MPa for 10 min and then washed with DNase solution or frozen at −80°C for 2 days and thawed. These menisci then underwent in vitro histological, biochemical, and biomechanical comparisons with native menisci. The HHP‐treated and freeze‐thawed menisci were also subcutaneously implanted in a pig, and later harvested for histological analysis. The numbers of histologically detected cells were significantly lower and the amount of biochemically detected DNA was approximately 100‐fold lower in HHP‐treated than in native and freeze‐thawed menisci. The compression strength of the HHP‐decellularized menisci was decreased after 1 and 50 cycles at 20% strain but was unchanged in the freeze‐thawed menisci. After implantation, the numbers of multinucleated giant cells were significantly lower around the HHP‐treated menisci than around the freeze‐thawed menisci. Recellularization of the HHP‐decellularized menisci was confirmed. Thus, although the HHP‐decellularized menisci were mechanically inferior to the freeze‐thawed meniscus in vitro, they were immunologically superior. Our study is the first to demonstrate the use of HHP for decellularization of the meniscus. © 2019 The Authors. Journal of Orthopaedic Research® published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 37:2466–2475, 2019

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jor.24350

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 33

Metadata

Authors
Watanabe, N., Mizuno, M., Matsuda, J., Nakamura, N., Otabe, K., Katano, H., Ozeki, N., Kohno, Y., Kimura, T., Tsuji, K., Koga, H., Kishida, A., & Sekiya, I.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
2019-06-20
Volume
37
Issue
11
Pages
2466-2475
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W2945488904
Cited by
33
References
3
FWCI
3.67
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of High‐Hydrostatic‐Pressure Decellularized Versus Freeze‐Thawed Porcine Menisci. https://app.cochat.ai/papers/10.1002/jor.24350
The paper
Watanabe, N., Mizuno, M., Matsuda, J., Nakamura, N., Otabe, K., Katano, H., Ozeki, N., Kohno, Y., Kimura, T., Tsuji, K., Koga, H., Kishida, A., & Sekiya, I. (2019). Comparison of High‐Hydrostatic‐Pressure Decellularized Versus Freeze‐Thawed Porcine Menisci. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.24350

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.