The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
An intelligent background‐correction algorithm for highly fluorescent samples in Raman spectroscopy
Abstract
Fluorescent background is a major problem in recoding the Raman spectra of many samples, which swamps or obscures the Raman signals. The background should be suppressed in order to perform further qualitative or quantitative analysis of the spectra. For this purpose, an intelligent background‐correction algorithm is developed, which simulates manual background‐correction procedure intelligently. It basically consists of three aspects: (1) accurate peak position detection in the Raman spectrum by continuous wavelet transform (CWT) with the Mexican Hat wavelet as the mother wavelet; (2) peak‐width estimation by signal‐to‐noise ratio (SNR) enhancing derivative calculation based on CWT but with the Haar wavelet as the mother wavelet; and (3) background fitting using penalized least squares with binary masks. This algorithm does not require any preprocessing step for transforming the spectrum into the wavelet space and can suppress the fluorescent background of Raman spectra intelligently and validly. The algorithm is implemented in R language and available as open source software (http://code.google.com/p/baselinewavelet). Copyright © 2009 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eilers, P. H. C. (2003) · Analytical Chemistry · doi:10.1021/ac034173t · Cited by 1,340
Automated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
Zhao, J., Lui, H., McLean, D. I., & Zeng, H. (2007) · Applied Spectroscopy · doi:10.1366/000370207782597003 · Cited by 810
Du, P., Kibbe, W. A., & Lin, S. M. (2006) · Bioinformatics · doi:10.1093/bioinformatics/btl355 · Cited by 763
Whittaker, E. T. (1922) · Proceedings of the Edinburgh Mathematical Society · doi:10.1017/s0013091500077853 · Cited by 504
Background removal from spectra by designing and minimising a non-quadratic cost function
Mazet, V., Carteret, C., Brie, D., Idier, J., & Humbert, B. (2005) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2004.10.003 · Cited by 316
A new general-purpose fully automatic baseline-correction procedure for 1D and 2D NMR data
Cobas, J. C., Bernstein, M. A., Martín‐Pastor, M., & Tahoces, P. G. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.07.013 · Cited by 148
Noise and background removal in Raman spectra of ancient pigments using wavelet transform
Ramos, P. M., & Ruisánchez, I. (2005) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1370 · Cited by 136
A general approach to derivative calculation using wavelet transform
Shao, X., & Ma, C. (2003) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2003.08.001 · Cited by 136
Quantitative analysis of serum and serum ultrafiltrate by means of Raman spectroscopy
Rohleder, D., Kiefer, W., & Petrich, W. H. (2004) · The Analyst · doi:10.1039/b408927h · Cited by 109
O'Grady, A., Dennis, A. C., Denvir, D. J., McGarvey, J. J., & Bell, S. E. J. (2001) · Analytical Chemistry · doi:10.1021/ac0010072 · Cited by 93
Shao, X., Pang, C., & Su, Q. (2000) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160000404 · Cited by 64
Chemical Segregation and Reduction of Raman Background Interference Using Drop Coating Deposition
Zhang, D., Mrozek, M. F., Xie, Y. Q., & Ben‐Amotz, D. (2004) · Applied Spectroscopy · doi:10.1366/0003702041655430 · Cited by 62
Separation of Raman spectra from fluorescence emission background by principal component analysis
Hasegawa, T., Nishijo, J., & Umemura, J. (2000) · Chemical Physics Letters · doi:10.1016/s0009-2614(99)01427-x · Cited by 53
Macdonald, A. M., & Wyeth, P. (2006) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1510 · Cited by 48
Osticioli, I., Zoppi, A., & Castellucci, E. (2006) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1587 · Cited by 47
Osticioli, I., Zoppi, A., & Castellucci, E. (2007) · Applied Spectroscopy · doi:10.1366/000370207781540169 · Cited by 38
Oshima, Y., Komachi, Y., Furihata, C., Tashiro, H., & Sato, H. (2006) · Applied Spectroscopy · doi:10.1366/000370206778397344 · Cited by 22
Cited by
Baseline correction using adaptive iteratively reweighted penalized least squares
Zhang, Z.-M., Chen, S., & Liang, Y.-Z. (2010) · The Analyst · doi:10.1039/b922045c · Cited by 1,124
Self-citationReview of multidimensional data processing approaches for Raman and infrared spectroscopy
Gautam, R., Vanga, S., Ariese, F., & Umapathy, S. (2015) · EPJ Techniques and Instrumentation · doi:10.1140/epjti/s40485-015-0018-6 · Cited by 696
Spectral pre-processing for biomedical vibrational spectroscopy and microspectroscopic imaging
Lasch, P. (2012) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2012.03.011 · Cited by 353
Clinical instrumentation and applications of Raman spectroscopy
Pence, I., & Mahadevan-Jansen, A. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00581g · Cited by 352
Review of Fluorescence Suppression Techniques in Raman Spectroscopy
Wei, D., Chen, S., & Liu, Q. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2014.999936 · Cited by 334
Self-citation
Metadata
- Authors
- Zhang, Z., Chen, S., Liang, Y., Liu, Z., Zhang, Q., Ding, L., Ye, F., & Zhou, H.
- Venue
- Journal of Raman Spectroscopy
- Publisher
- Wiley
- Published
- 2009-10-09
- Volume
- 41
- Issue
- 6
- Pages
- 659-669
- ISSN
- 0377-0486 (ISSN-L)
- 1097-4555
- OpenAlex
- W2142659066
- Cited by
- 308
- References
- 17
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.