The DOI matches its Crossref record.
Automated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
Abstract
A significant advantage of Raman spectroscopy as a noninvasive optical technique is its ability to detect subtle molecular or biochemical signatures within tissue. One of the major challenges for biomedical Raman spectroscopy is the removal of intrinsic autofluorescence background signals, which are usually a few orders of magnitude stronger than those arising from Raman scattering. A number of methods have been proposed for fluorescence background removal including excitation wavelength shifting, Fourier transformation, time gating, and simple or modified polynomial fitting. The single polynomial and the modified multi-polynomial fitting methods are relatively simple and effective, and thus are widely used in biological applications. However, their performance in real-time in vivo applications and low signal-to-noise ratio environments is sub-optimal. An improved automated algorithm for fluorescence removal has been developed based on modified multi-polynomial fitting, but with the addition of (1) a peak-removal procedure during the first iteration, and (2) a statistical method to account for signal noise effects. Experimental results demonstrate that this approach improves the automated rejection of the fluorescence background during real-time Raman spectroscopy and for in vivo measurements characterized by low signal-to-noise ratios.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Gautam, R., Vanga, S., Ariese, F., & Umapathy, S. (2015) · EPJ Techniques and Instrumentation · doi:10.1140/epjti/s40485-015-0018-6 · Cited by 696
Feng, S., Chen, R., Lin, J., Pan, J., Chen, G., Li, Y., Cheng, M., Huang, Z., Chen, J., & Zeng, H. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.03.033 · Cited by 450
Self-citationSpectral pre-processing for biomedical vibrational spectroscopy and microspectroscopic imaging
Lasch, P. (2012) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2012.03.011 · Cited by 353
Berry, B., Moretto, J., Matthews, T., Smelko, J., & Wiltberger, K. (2015) · Biotechnology Progress · doi:10.1002/btpr.2035 · Cited by 142
Full range characterization of the Raman spectra of organs in a murine model
Huang, N., Short, M., Zhao, J., Wang, H., Lui, H., Korbelik, M., & Zeng, H. (2011) · Optics Express · doi:10.1364/oe.19.022892 · Cited by 131
Self-citation
Metadata
- Authors
- Zhao, J., Lui, H., McLean, D. I., & Zeng, H.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2007-11
- Volume
- 61
- Issue
- 11
- Pages
- 1225-1232
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2091998550
- Cited by
- 810
- References
- 0
- FWCI
- 5.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy. https://app.cochat.ai/papers/10.1366/000370207782597003
- The paper
- Zhao, J., Lui, H., McLean, D. I., & Zeng, H. (2007). Automated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy. Applied Spectroscopy. https://doi.org/10.1366/000370207782597003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.