Molecular‐imprinted polymer extraction combined with dispersive liquid–liquid micro‐extractionfor ultra‐preconcentration of mononitrotoluene
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Molecular‐imprinted polymer (MIP) combined with dispersive liquid–liquid micro‐extraction (DLLME) were developed for ultra‐preconcentration and determination of mononitrotoluenes in wastewater samples using gas chromatography–flame ionization detector. MIP was synthesized by copolymerization of methacrylic acid–ethylene glycole dimethacrylate–2,2‐azobisisobutyronitrile as the initiator that imprinted with 3‐nitrotoluene as the template molecule. Effects of several factors, such as type and volume of eluent, adsorption, and desorption times of the analyte on the polymer, and breakthrough volume were investigated. Optimization of 3‐nitrotoluene extraction from MIP was studied forward followed by DLLME. Preconcentration factor of MIP‐DLLME method was about 2800 under the optimum conditions. The LOD of the proposed method was 0.02 μg/L and a linear dynamic range in the range of 0.04–20 μg/L was obtained. The performance of the present method was evaluated for extraction and determination of nitrotoluene compounds in wastewater samples in the range of microgram per liter and satisfactory results were achieved (RSD<13%).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Fattahi, N., Assadi, Y., Hosseini, M. R. M., & Jahromi, E. Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.062 · Cited by 366
Chen, Y., Guo, Z., Wang, X., & Qiu, C. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.026 · Cited by 316
Fattahi, N., Samadi, S., Assadi, Y., & Hosseini, M. R. M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.09.002 · Cited by 178
Ebrahimzadeh, H., Yamini, Y., & Kamarei, F. (2009) · Talanta · doi:10.1016/j.talanta.2009.06.022 · Cited by 99
Self-citation
Cited by
Molecular imprinting: perspectives and applications
Chen, L., Wang, X., Lu, W., Wu, X., & Li, J. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00061d · Cited by 2,460
Dispersive liquid-liquid microextraction
Zgoła-Grześkowiak, A., & Grześkowiak, T. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.04.014 · Cited by 476
Whitcombe, M. J., Kirsch, N., & Nicholls, I. A. (2014) · Journal of Molecular Recognition · doi:10.1002/jmr.2347 · Cited by 445
Recent advances in solid-phase sorbents for sample preparation prior to chromatographic analysis
Wen, Y., Chen, L., Li, J., Liu, D., & Chen, L. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.03.011 · Cited by 369
Recent development and applications of dispersive liquid–liquid microextraction
Yan, H., & Wang, H. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.04.053 · Cited by 256
Metadata
- Authors
- Ebrahimzadeh, H., Abedi, H., Yamini, Y., & Adlnasab, L.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2010-10-28
- Volume
- 33
- Issue
- 23-24
- Pages
- 3759-3766
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W1995834010
- Cited by
- 35
- References
- 5
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.