CoChat

Orthogonal array design for the optimization of ionic liquid‐based dispersive liquid–liquid microextraction of benzophenone‐type UV filters

Ye, Lei, Liu, Juanjuan, Yang, Xin, Peng, Yan, Xu, Li · 2011 · Journal of Separation Science
Cited by 61

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

In the present study, dispersive liquid–liquid microextraction (DLLME) using an ionic liquid (IL) as the extractant was successfully developed to extract four benzophenone‐type UV filters from the different water matrices. Orthogonal array experimental design (OAD), based on five factors and four levels (L 16(4 5)), was employed to optimize IL‐dispersive liquid–liquid microextraction procedure. The five factors included pH of sample solution, the volume of IL and methanol addition, extraction time and the amount of salt added. The optimal extraction condition was as follows. Sample solution was at a pH of 2.63 in the presence of 60 mg/mL sodium chloride; 30 μL IL and 15 μL methanol were used as extractant and disperser solvent, respectively; extraction was achieved by vortexing for 4 min. Using high‐performance liquid chromatography‐UV analysis, the limits of detection of the target analytes ranged between 1.9 and 6.4 ng/mL. The linear ranges were between 10 or 20 ng/mL and 1000 ng/mL. This procedure afforded a convenient, fast and cost‐saving operation with high extraction efficiency for the model analytes. Spiked waters from two rivers and one lake were examined by the developed method. For the swimming pool water, the standard addition method was employed to determine the actual concentrations of the UV filters.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jssc.201000552

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 61

Metadata

Authors
Ye, L., Liu, J., Yang, X., Peng, Y., & Xu, L.
Venue
Journal of Separation Science
Publisher
Wiley
Published
2011-02-02
Volume
34
Issue
6
Pages
700-706
ISSN
  • 1615-9306 (ISSN-L)
  • 1615-9314
OpenAlex
W2137406110
Cited by
61
References
11
FWCI
6.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Orthogonal array design for the optimization of ionic liquid‐based dispersive liquid–liquid microextraction of benzophenone‐type UV filters. https://app.cochat.ai/papers/10.1002/jssc.201000552
The paper
Ye, L., Liu, J., Yang, X., Peng, Y., & Xu, L. (2011). Orthogonal array design for the optimization of ionic liquid‐based dispersive liquid–liquid microextraction of benzophenone‐type UV filters. Journal of Separation Science. https://doi.org/10.1002/jssc.201000552

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.