Optimization of dispersive liquid–liquid microextraction based on the solidification of floating organic droplets using an orthogonal array design and its application for the determination of fungicide concentrations in environmental water samples
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A dispersive liquid–liquid microextraction method based on the solidification of floating organic droplets was developed as a simple and sensitive method for the simultaneous determination of the concentrations of multiple fungicides (triazolone, chlorothalonil, cyprodinil, and trifloxystrobin) in water by high‐performance liquid chromatography with variable‐wavelength detection. After an approach varying one factor at a time was used, an orthogonal array design [L25 (5 5)] was employed to optimize the method and to determine the interactions between the parameters. The significance of the effects of the different factors was determined using analysis of variance. The results indicated that the extraction solvent volume significantly affects the efficiency of the extraction. Under optimal conditions, the relative standard deviation (n = 5) varied from 2.3 to 5.5% at 0.1 μg/mL for each analyte. Low limits of detection were obtained and ranged from 0.02 to 0.2 ng/mL. In addition, the proposed method was applied to the analysis of fungicides in real water samples. The results show that the dispersive liquid–liquid microextraction based on the solidification of floating organic droplets is a potential method for detecting fungicides in environmental water samples, with recoveries of the target analytes ranging from 70.1 to 102.5%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Leong, M.-I., & Huang, S.-D. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.09.111 · Cited by 413
Sobhi, H. R., Yamini, Y., Esrafili, A., & Abadi, R. H. H. B. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.05.005 · Cited by 77
Zang, X., Wang, J., Wang, O., Wang, M., Ma, J., Xi, G., & Wang, Z. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2296-1 · Cited by 75
Cited by
Mansour, F. R., & Danielson, N. D. (2017) · Talanta · doi:10.1016/j.talanta.2017.03.084 · Cited by 178
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Recent achievements in solidified floating organic drop microextraction
Viñas, P., Campillo, N., & Andruch, V. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.02.005 · Cited by 99
Jia, L., Huang, X., Zhao, W., Wang, H., & Jing, X. (2020) · Food Chemistry · doi:10.1016/j.foodchem.2020.126424 · Cited by 96
Metadata
- Authors
- Yang, X., Yang, M., Hou, B., Li, S., Zhang, Y., Lu, R., & Zhang, S.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2014-06-11
- Volume
- 37
- Issue
- 15
- Pages
- 1996-2001
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2063443892
- Cited by
- 23
- References
- 3
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.