In situ ionic‐liquid‐dispersive liquid–liquid microextraction of Sudan dyes from liquid samples
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In situ ionic‐liquid‐dispersive liquid–liquid microextraction was introduced for extracting Sudan dyes from different liquid samples followed by detection using ultrafast liquid chromatography. The extraction and metathesis reaction can be performed simultaneously, the extraction time was shortened notably and higher enrichment factors can be obtained compared with traditional dispersive liquid–liquid microextraction. When the extraction was coupled with ultrafast liquid chromatography, a green, convenient, cheap, and efficient method for the determination of S udan dyes was developed. The effects of various experimental factors, including type of extraction solvent, amount of 1‐hexyl‐3‐methylimidazolium chloride, ratio of ammonium hexafluorophosphate to 1‐hexyl‐3‐methylimidazolium chloride, pH value, salt concentration in sample solution, extraction time and centrifugation time were investigated and optimized for the extraction of four kinds of Sudan dyes. The limits of detection for Sudan I, II, III, and IV were 0.324, 0.299, 0.390, and 0.655 ng/mL, respectively. Recoveries obtained by analyzing the seven spiked samples were between 65.95 and 112.82%. The consumption of organic solvent (120 μL acetonitrile per sample) was very low, so it could be considered as a green analytical method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Temperature-controlled ionic liquid dispersive liquid phase micro-extraction
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.103 · Cited by 303
Yao, C., & Anderson, J. L. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3078-0 · Cited by 204
Bai, H., Zhou, Q., Xie, G., & Xiao, J. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.08.011 · Cited by 67
Cited by
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
“In most of these procedures, the IL is added to the aqueous phase; nevertheless, in situ formation of the IL extractant phase allows the disperser solvent to be omitted, which would otherwise increase the solubility of the analytes in the aqueous phase (12, 93, 136, 256, 288, 349, 482, 536, 801, 944, 958, 1012, 1062,…”
BackgroundGe, D., Shan, Z., Pang, T., Lu, X., & Wang, B. (2021) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03337-0 · Cited by 38
Ozalp, O., & Soylak, M. (2023) · Analytical Letters · doi:10.1080/00032719.2023.2175212 · Cited by 28
Greening Sample Preparation: New Solvents, New Sorbents
Ramos, L. (2020) · Challenges in Green Analytical Chemistry · doi:10.1039/9781788016148-00114 · Cited by 6
Metadata
- Authors
- Xu, B., Song, D., Wang, Y., Gao, Y., Cao, B., Zhang, H., & Sun, Y.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2014-06-20
- Volume
- 37
- Issue
- 15
- Pages
- 1967-1973
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2095718600
- Cited by
- 21
- References
- 3
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In situ ionic‐liquid‐dispersive liquid–liquid microextraction of Sudan dyes from liquid samples. https://app.cochat.ai/papers/10.1002/jssc.201400317
- The paper
- Xu, B., Song, D., Wang, Y., Gao, Y., Cao, B., Zhang, H., & Sun, Y. (2014). In situ ionic‐liquid‐dispersive liquid–liquid microextraction of Sudan dyes from liquid samples. Journal of Separation Science. https://doi.org/10.1002/jssc.201400317
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.