CoChat

Ligandless, deep eutectic solvent‐based ultrasound‐assisted dispersive liquid‐liquid microextraction with solidification of the aqueous phase for preconcentration of lead, cadmium, cobalt and nickel in water samples

Werner, Justyna · 2020 · Journal of Separation Science

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Abstract

A green and efficient sample preparation method using a deep eutectic solvent‐based ultrasounds‐assisted dispersive liquid–liquid microextraction with solidification of the aqueous phase followed by high performance liquid chromatography analysis was developed for preconcentration and determination of heavy metals in environmental samples. In the proposed method, a novel, low density deep eutectic solvent was prepared by mixing trihexyl(tetradecyl)phosphonium chloride and thiosalicylic acid at a molar ratio of 1:2 and used both as an extractant and complexing agent. Ultrasound was used to disperse the extractant in the aqueous phase of the sample. Then, the phases were separated by centrifugation, after which the aqueous phase was frozen and the surface extractant phase was dissolved in a small volume of acetonitrile and subjected to liquid chromatographic analysis. The proposed method provided precisions (relative standard deviation, n = 5) in the range of 2.6–4.7%. The limit of detection were 0.05, 0.13, 0.06, and 0.11 µg/L for Pb(II), Cd(II), Co(II), Ni(II), respectively. The enhancement factors were equal to 154, 159, 162, and 158 for lead(II), cadmium(II), cobalt(II), and nickel(II), respectively. The accuracy of the proposed method was evaluated using certified reference materials (CA011b – hard drinking water, NIST 1643e – trace elements in water, TMRAIN‐04 – simulated rain sample).

Overview

Integrity signals

Registry

Crossref · 10.1002/jssc.201901184

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 39 references

Research works printed but not linked: 1

  1. Razmislevičienė I., 2011, Ionic liquid‐based dispersive liquid‐liquid micro‐extraction combined with ultra performance liquid chromatography for the determination of metal ions, Chemija, 22, 197

Cited by

Metadata

Authors
Werner, J.
Affiliations
Poznań University of Technology (PL)
Corresponding author
Werner, Justyna
Venue
Journal of Separation Science
Publisher
Wiley
Published
2020-01-09
Volume
43
Issue
7
Pages
1297-1305
ISSN
  • 1615-9306 (ISSN-L)
  • 1615-9314
OpenAlex
W2997159461
Cited by
38
References
39
Citations by year
2026: 5 · 2025: 5 · 2024: 7 · 2023: 6 · 2022: 5 · 2021: 5 · 2020: 5
FWCI
2.10
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Separation Science (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Materials Science › Metals and Alloys › Extraction and Separation Processes
Keywords
deep eutectic solvents, ultrasound-assisted dispersive liquid-liquid microextraction, heavy metal preconcentration, lead, cadmium, cobalt, nickel, thiosalicylic acid, water samples, green sample preparation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.