The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Sensitivity‐enhancement methods for surface plasmon sensors
Abstract
Surface plasmon resonance (SPR) sensors have been a mature technology for more than two decades now, however, recent investigations show continuous enhancement of their sensitivity and their lower detection limit. Together with the recent investigations in localized SPR phenomena, extraordinary optical transmission through nanoapertures in metals, and surface‐enhanced spectroscopies, drastic developments are expected to revolutionize the field of optical biosensing. Sensitivity‐enhancement (SE) techniques are reviewed focusing both on the physical transduction mechanisms and the system performance. In the majority of cases the SE is associated with the enhancement of the electromagnetic field overlap integral describing the interaction energy within the analyte. Other important mechanisms are the interaction between plasmons and excitons and between the analyte molecules and the metal surface. The lower detection limit can be reduced significantly if systems with high signal‐to‐noise ratio are used such as common‐path interferometry, ellipsometry or polarimetry systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Haes, A. J., & Van Duyne, R. P. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020393x · Cited by 2,057
Cited by
Damborský, P., Švitel, J., & Katrlík, J. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150010 · Cited by 907
Review of plasmonic fiber optic biochemical sensors: improving the limit of detection
Caucheteur, C., Guo, T., & Albert, J. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-8411-6 · Cited by 729
Ouyang, Q., Zeng, S., Jiang, L., Hong, L., Xu, G., Dinh, X.-Q., Qian, J., He, S., Qu, J., Coquet, P., et al. (2016) · Scientific Reports · doi:10.1038/srep28190 · Cited by 420
Determining the Interfacial Refractive Index via Ultrasensitive Plasmonic Sensors
Zhan, C., Liu, B.-W., Tian, Z.-Q., & Ren, B. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c01907 · Cited by 56
Metadata
- Authors
- Shalabney, A., & Abdulhalim, I.
- Venue
- Laser & Photonics Reviews
- Publisher
- Wiley
- Published
- 2011-03-29
- Volume
- 5
- Issue
- 4
- Pages
- 571-606
- ISSN
- 1863-8880 (ISSN-L)
- 1863-8899
- OpenAlex
- W2066029042
- Cited by
- 551
- References
- 1
- FWCI
- 12.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitivity‐enhancement methods for surface plasmon sensors. https://app.cochat.ai/papers/10.1002/lpor.201000009
- The paper
- Shalabney, A., & Abdulhalim, I. (2011). Sensitivity‐enhancement methods for surface plasmon sensors. Laser & Photonics Reviews. https://doi.org/10.1002/lpor.201000009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.