Recent progress in tissue optical clearing
Open accessThe DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Abstract
Tissue optical clearing technique provides a prospective solution for the application of advanced optical methods in life sciences. This paper gives a review of recent developments in tissue optical clearing techniques. The physical, molecular and physiological mechanisms of tissue optical clearing are overviewed and discussed. Various methods for enhancing penetration of optical‐clearing agents into tissue, such as physical methods, chemical‐penetration enhancers and combination of physical and chemical methods are introduced. Combining the tissue optical clearing technique with advanced microscopy image or labeling technique, applications for 3D microstructure of whole tissues such as brain and central nervous system with unprecedented resolution are demonstrated. Moreover, the difference in diffusion and/or clearing ability of selected agents in healthy versus pathological tissues can provide a highly sensitive indicator of the tissue health/pathology condition. Finally, recent advances in optical clearing of soft or hard tissue for in vivo imaging and phototherapy are introduced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Tissue Optics: Light Scattering Methods and Instruments for Medical Diagnosis
Tuchin, V. V. (2015) · SPIE eBooks · doi:10.1117/3.1003040 · Cited by 1,352
Self-citationUltramicroscopy: three-dimensional visualization of neuronal networks in the whole mouse brain
Dodt, H.-U., Leischner, U., Schierloh, A., Jährling, N., Mauch, C. P., Deininger, K., Deussing, J. M., Eder, M., Zieglgänsberger, W., & Becker, K. (2007) · Nature Methods · doi:10.1038/nmeth1036 · Cited by 1,238
Long-term dendritic spine stability in the adult cortex
Grutzendler, J., Kasthuri, N., & Gan, W.-B. (2002) · Nature · doi:10.1038/nature01276 · Cited by 1,198
Scale: a chemical approach for fluorescence imaging and reconstruction of transparent mouse brain
Hama, H., Kurokawa, H., Kawano, H., Ando, R., Shimogori, T., Noda, H., Fukami, K., Sakaue-Sawano, A., & Miyawaki, A. (2011) · Nature Neuroscience · doi:10.1038/nn.2928 · Cited by 1,142
Laser speckle contrast imaging in biomedical optics
Boas, D. A., & Dunn, A. K. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3285504 · Cited by 1,122
Principles of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
Long-term, high-resolution imaging in the mouse neocortex through a chronic cranial window
Holtmaat, A., Bonhoeffer, T., Chow, D. K., Chuckowree, J., De Paola, V., Hofer, S. B., Hübener, M., Keck, T., Knott, G., Lee, W.-C. A., et al. (2009) · Nature Protocols · doi:10.1038/nprot.2009.89 · Cited by 1,023
Three-dimensional imaging of solvent-cleared organs using 3DISCO
Ertürk, A., Becker, K., Jährling, N., Mauch, C. P., Hojer, C. D., Egen, J. G., Hellal, F., Bradke, F., Sheng, M., & Dodt, H.-U. (2012) · Nature Protocols · doi:10.1038/nprot.2012.119 · Cited by 992
Determining the optical properties of turbid media by using the adding–doubling method
Prahl, S. A., van Gemert, M. J. C., & Welch, A. J. (1993) · Applied Optics · doi:10.1364/ao.32.000559 · Cited by 931
Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging
Briers, J. D. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/4/201 · Cited by 686
Briers, J. D. (1996) · Journal of Biomedical Optics · doi:10.1117/12.231359 · Cited by 686
Micro-Optical Sectioning Tomography to Obtain a High-Resolution Atlas of the Mouse Brain
Li, A., Gong, H., Zhang, B., Wang, Q., Yan, C., Wu, J., Liu, Q., Zeng, S., & Luo, Q. (2010) · Science · doi:10.1126/science.1191776 · Cited by 521
Self-citationLight propagation in tissues with controlled optical properties
Tuchin, V. V. (1997) · Journal of Biomedical Optics · doi:10.1117/1.429841 · Cited by 411
Self-citationChoice of cranial window type for in vivo imaging affects dendritic spine turnover in the cortex
Xu, H.-T., Pan, F., Yang, G., & Gan, W.-B. (2007) · Nature Neuroscience · doi:10.1038/nn1883 · Cited by 410
Chronic optical access through a polished and reinforced thinned skull
Drew, P. J., Shih, A. Y., Driscoll, J. D., Knutsen, P. M., Blinder, P., Davalos, D., Akassoglou, K., Tsai, P. S., & Kleinfeld, D. (2010) · Nature Methods · doi:10.1038/nmeth.1530 · Cited by 406
Design principles of chemical penetration enhancers for transdermal drug delivery
Karande, P., Jain, A., Ergun, K., Kispersky, V., & Mitragotri, S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501176102 · Cited by 399
Optical Clearing of Tissues and Blood
Tuchin, V. V. (2005) · SPIE eBooks · doi:10.1117/3.637760 · Cited by 351
Self-citationTuchin, V. (2007) · SPIE eBooks · doi:10.1117/3.684093 · Cited by 349
Self-citationErtürk, A., Mauch, C. P., Hellal, F., Förstner, F., Keck, T., Becker, K., Jährling, N., Steffens, H., Richter, M., Hübener, M., et al. (2012) · Nature Medicine · doi:10.1038/nm.2600 · Cited by 321
Optical Coherence Tomography: History, Current Status, and Laboratory Work
Gabriele, M. L., Wollstein, G., Ishikawa, H., Kagemann, L., Xu, J., Folio, L. S., & Schuman, J. S. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6312 · Cited by 310
Use of an agent to reduce scattering in skin
Vargas, G., Chan, E. K., Barton, J. K., Rylander, H. G., & Welch, A. J. (1999) · Lasers in Surgery and Medicine · doi:10.1002/(sici)1096-9101(1999)24:2<133::aid-lsm9>3.0.co;2-x · Cited by 302
Chemical Clearing and Dehydration of GFP Expressing Mouse Brains
Becker, K., Jährling, N., Saghafi, S., Weiler, R., & Dodt, H.-U. (2012) · PLoS ONE · doi:10.1371/journal.pone.0033916 · Cited by 300
Optical coherence tomography – development, principles, applications
Fercher, A. F. (2010) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2009.11.002 · Cited by 259
Modified laser speckle imaging method with improved spatial resolution
Cheng, H., Luo, Q., Zeng, S., Chen, S., Cen, J., & Gong, H. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1578089 · Cited by 256
Self-citationGraaff, R., Aarnoudse, J. G., Zijp, J. R., Sloot, P. M. A., de Mul, F. F. M., Greve, J., & Koelink, M. H. (1992) · Applied Optics · doi:10.1364/ao.31.001370 · Cited by 241
Optical clearing of tissues and blood using the immersion method
Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/001 · Cited by 232
Self-citationA Map of Olfactory Representation in the Drosophila Mushroom Body
Lin, H.-H., Lai, J. S.-Y., Chin, A.-L., Chen, Y.-C., & Chiang, A.-S. (2007) · Cell · doi:10.1016/j.cell.2007.03.006 · Cited by 223
Tissue optical immersion clearing
Genina, E. A., Bashkatov, A. N., & Tuchin, V. V. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.50 · Cited by 208
Self-citationReversible Dissociation of Collagen in Tissues
Yeh, A. T., Choi, B., Nelson, J. S., & Tromberg, B. J. (2003) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2003.12634.x · Cited by 199
Capillary Blood Flow Monitoring Using Laser Speckle Contrast Analysis (LASCA)
Briers, J. D., Richards, G., & He, X. W. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429903 · Cited by 197
Handbook of Optical Sensing of Glucose in Biological Fluids and Tissues
(2008) · CRC Press eBooks · doi:10.1201/9781584889755 · Cited by 185
Dehydration mechanism of optical clearing in tissue
Rylander, C. G., Stumpp, O. F., Milner, T. E., Kemp, N. J., Mendenhall, J. M., Diller, K. R., & Welch, A. J. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2343208 · Cited by 160
Kim, J.-W., Shashkov, E. V., Galanzha, E. I., Kotagiri, N., & Zharov, V. P. (2007) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20534 · Cited by 159
In vivo skin optical clearing by glycerol solutions: mechanism
Wen, X., Mao, Z., Han, Z., Tuchin, V. V., & Zhu, D. Y. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910080 · Cited by 158
Self-citationOptical coherence tomography—current technology and applications in clinical and biomedical research
Marschall, S., Sander, B., Mogensen, M., Jørgensen, T. M., & Andersen, P. E. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5008-1 · Cited by 139
Optical Clearing for Improved Contrast in Second Harmonic Generation Imaging of Skeletal Muscle
Plotnikov, S. V., Juneja, V., Isaacson, A. B., Mohler, W. A., & Campagnola, P. J. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.066944 · Cited by 135
Skin microcirculation in peripheral arterial obliterative disease
Rossi, M., & Carpi, A. (2004) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2004.08.004 · Cited by 120
Optical Clearing for OCT Image Enhancement and In-Depth Monitoring of Molecular Diffusion
Larin, K. V., Ghosn, M. G., Bashkatov, A. N., Genina, E. A., Trunina, N. A., & Tuchin, V. V. (2011) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2011.2181991 · Cited by 117
Self-citationCicchi, R., Pavone, F. S., Massi, D., & Sampson, D. D. (2005) · Optics Express · doi:10.1364/opex.13.002337 · Cited by 117
Galanzha, E. I., Kokoska, M. S., Shashkov, E. V., Kim, J.-W., Tuchin, V. V., & Zharov, V. P. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910046 · Cited by 107
Self-citationHe, Y.-H., & Wang, R. K. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1629682 · Cited by 104
Ghosn, M. G., Tuchin, V. V., & Larin, K. V. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-1331 · Cited by 101
Self-citationDickie, R., Bachoo, R. M., Rupnick, M. A., Dallabrida, S. M., DeLoid, G. M., Lai, J., DePinho, R. A., & Rogers, R. A. (2006) · Microvascular Research · doi:10.1016/j.mvr.2006.05.003 · Cited by 93
An innovative transparent cranial window based on skull optical clearing
Wang, J., Zhang, Y., Xu, T., Luo, Q., & Zhu, D. Y. (2012) · Laser Physics Letters · doi:10.7452/lapl.201210017 · Cited by 92
Self-citationYeh, A. T., & Hirshburg, J. M. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2166381 · Cited by 91
Jiang, J., & Wang, R. K. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/23/006 · Cited by 90
Correlation between collagen solubility and skin optical clearing using sugars
Hirshburg, J. M., Choi, B., Nelson, J. S., & Yeh, A. T. (2007) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20417 · Cited by 89
A dynamic zone defines interneuron remodeling in the adult neocortex
Lee, W.-C. A., Chen, J. L., Huang, H., Leslie, J. H., Amitai, Y., So, P. T., & Nedivi, E. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810149105 · Cited by 87
Nadiarnykh, O., & Campagnola, P. J. (2009) · Optics Express · doi:10.1364/oe.17.005794 · Cited by 81
Genina, E. A., Bashkatov, A. N., Korobko, A. A., Zubkova, E. A., Tuchin, V. V., Yaroslavsky, I. V., & Altshuler, G. B. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2899149 · Cited by 80
Self-citationXu, X., & Wang, R. K. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/008 · Cited by 79
Molecular basis for optical clearing of collagenous tissues
Hirshburg, J. M., Ravikumar, K. M., Hwang, W., & Yeh, A. T. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3484748 · Cited by 74
A Clear Vision for Laser Diagnostics (Review)
Tuchin, V. V. (2007) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2007.911313 · Cited by 70
Self-citationLaComb, R. B., Nadiarnykh, O., Carey, S. P., & Campagnola, P. J. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2907207 · Cited by 70
Zimmerley, M., McClure, R. A., Choi, B., & Potma, E. O. (2009) · Applied Optics · doi:10.1364/ao.48.000d79 · Cited by 70
Differential permeability rate and percent clearing of glucose in different regions in rabbit sclera
Ghosn, M. G., Carbajal, E. F., Befrui, N. A., Tuchin, V. V., & Larin, K. V. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2907699 · Cited by 68
Self-citationThe Enhancement of Confocal Images of Tissues at Bulk Optical ImmersionPreprint
Meglinski, I. V., Churmakov, D. Y., Bashkatov, A. N., Genina, E. A., & Tuchin, V. V. (2004) · arXiv (Cornell University) · doi:10.48550/arxiv.physics/0401104 · Cited by 67
Self-citationSwitchable skin window induced by optical clearing method for dermal blood flow imaging
Wang, J., Shi, R., & Zhu, D. Y. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.6.061209 · Cited by 64
Self-citationMonitoring of glucose permeability in monkey skin in vivo using Optical Coherence Tomography
Ghosn, M. G., Sudheendran, N., Wendt, M., Glasser, A., Tuchin, V. V., & Larin, K. V. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910075 · Cited by 63
Self-citationEffect of Localized Mechanical Indentation on Skin Water Content Evaluated Using OCT
Gurjarpadhye, A. A., Vogt, W. C., Liu, Y., & Rylander, C. G. (2011) · International Journal of Biomedical Imaging · doi:10.1155/2011/817250 · Cited by 56
Rylander, C. G., Milner, T. E., Baranov, S. A., & Nelson, J. S. (2008) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20718 · Cited by 55
Imaging of subcutaneous blood vessels and flow velocity profiles by optical coherence tomography
Bonesi, M., Proskurin, S. G., & Meglinski, I. V. (2010) · Laser Physics · doi:10.1134/s1054660x10070029 · Cited by 54
Zhu, D. Y., Lü, W., Weng, Y., et al. (2007) · Applied Optics · doi:10.1364/ao.46.001911 · Cited by 52
Self-citationPermeability of hyperosmotic agent in normal and atherosclerotic vascular tissues
Ghosn, M. G., Carbajal, E. F., Befrui, N. A., Téllez, A., Granada, J. F., & Larin, K. V. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2870153 · Cited by 50
Self-citationOptical clearing in transcutaneous Raman spectroscopy of murine cortical bone tissue
Schulmerich, M. V., Cole, J. H., Dooley, K. A., Morris, M. D., Kreider, J. M., & Goldstein, S. A. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2892687 · Cited by 46
Macdonald, C. M., & Meglinski, I. V. (2011) · Laser Physics Letters · doi:10.1002/lapl.201010133 · Cited by 46
Guo, X., Guo, Z., Wei, H., Yang, H., He, Y., Xie, S., Wu, G., Deng, X., Zhao, Q., & Li, L. (2011) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.2011.00908.x · Cited by 41
Combs, C. A., Смирнов, А. В., Riley, J. D., Gandjbakhche, A., Knutson, J. R., & Balaban, R. S. (2007) · Journal of Microscopy · doi:10.1111/j.1365-2818.2007.01851.x · Cited by 34
Kinnunen, M. T., Myllylä, R. A., & Vainio, S. J. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2904957 · Cited by 33
Combs, C. A., SMIRNOV, A., Chess, D. J., McGavern, D. B., Schroeder, J., RILEY, J., KANG, S. S., Luger-Hamer, M., Gandjbakhche, A., Knutson, J. R., et al. (2010) · Journal of Microscopy · doi:10.1111/j.1365-2818.2010.03411.x · Cited by 31
Zhong, H., Guo, Z., Wei, H., Zeng, C., Xiong, H., He, Y., & Liu, S. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3432750 · Cited by 31
Optical clearing of porcine skin tissue in vitro studied by Raman microspectroscopy
Huang, D., Zhang, W., Zhong, H., Xiong, H., Guo, X., & Guo, Z. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.1.015004 · Cited by 27
Dermal scatter reduction in human skin: A method using controlled application of glycerol
Fox, M. A., Diven, D. G., Sra, K., Boretsky, A. R., Poonawalla, T., Readinger, A., Motamedi, M., & McNichols, R. J. (2009) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20767 · Cited by 25
Light–Tissue Interaction at Optical Clearing
Genina, E. A., Bashkatov, A. N., Larin, K. V., & Tuchin, V. V. (2010) · Wiley eBooks · doi:10.1002/9783527632053.ch7 · Cited by 24
Self-citationIrreversible optical clearing of sclera by dehydration and cross-linking
Tanaka, Y., Kubota, A., Yamato, M., Okano, T., & Nishida, K. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.10.002 · Cited by 22
Ghosn, M. G., Mashiatulla, M., Syed, S. H., Mohamed, M., Larin, K. V., & Morrisett, J. D. (2011) · Journal of Lipid Research · doi:10.1194/jlr.d015255 · Cited by 14
Self-citation
Cited by
Deep imaging of bone marrow shows non-dividing stem cells are mainly perisinusoidal
Acar, M., Kocherlakota, K. S., Murphy, M. M., Peyer, J. G., Oguro, H., Inra, C. N., Jaiyeola, C., Zhao, Z., Luby-Phelps, K., & Morrison, S. J. (2015) · Nature · doi:10.1038/nature15250 · Cited by 696
Polarized light interaction with tissues
Tuchin, V. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071114 · Cited by 384
Self-citationSusaki, E. A., & Ueda, H. R. (2016) · Cell Chemical Biology · doi:10.1016/j.chembiol.2015.11.009 · Cited by 295
FDISCO: Advanced solvent-based clearing method for imaging whole organs
Qi, Y., Yu, T., Xu, J., Wan, P., Ma, Y., Zhu, J., Li, Y., Gong, H., Luo, Q., & Zhu, D. (2019) · Science Advances · doi:10.1126/sciadv.aau8355 · Cited by 257
Self-citationThe progress and perspectives of terahertz technology for diagnosis of neoplasms: a review
Zaytsev, K. I., Dolganova, I. N., Chernomyrdin, N. V., Katyba, G. M., Gavdush, A. A., Cherkasova, O. P., Komandin, G. A., Shchedrina, M. A., Khodan, A. N., Ponomarev, D. S., et al. (2020) · Journal of Optics · doi:10.1088/2040-8986/ab4dc3 · Cited by 205
“One promising solution to this problem is immersion optical clearing [12, 427, 428].”
BackgroundSelf-citation
Metadata
- Authors
- Zhu, D., Larin, K. V., Luo, Q., & Tuchin, V. V.
- Venue
- Laser & Photonics Reviews
- Publisher
- Wiley
- Published
- 2013-01-31
- Volume
- 7
- Issue
- 5
- Pages
- 732-757
- ISSN
- 1863-8880 (ISSN-L)
- 1863-8899
- OpenAlex
- W1570588423
- Cited by
- 394
- References
- 78
- FWCI
- 29.71
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.