Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 163

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Low‐Level Laser Therapy for Closed‐Head Traumatic Brain Injury in Mice: Effect of Different Wavelengths

Open access
Wu, Qiuhe, Xuan, Weijun, Ando, Takahiro, Xu, Tao, Huang, Liyi, Huang, Ying‐Ying, Dai, Tianghong, Dhital, Saphala, Sharma, Sulbha K., Whalen, Michael J., Hamblin, Michael R.·2012·Lasers in Surgery and Medicine

Abstract

Background and Objectives: Traumatic brain injury (TBI) affects millions worldwide and is without effective treatment. One area that is attracting growing interest is the use of transcranial low‐level laser therapy (LLLT) to treat TBI. The fact that near‐infrared light can penetrate into the brain would allow non‐invasive treatment to be carried out with a low likelihood of treatment‐related adverse events. LLLT may treat TBI by increasing respiration in the mitochondria, causing activation of transcription factors, reducing inflammatory mediators and oxidative stress, and inhibiting apoptosis. Study Design/Materials and Methods: We tested LLLT in a mouse model of closed‐head TBI produced by a controlled weight drop onto the skull. Mice received a single treatment with continuous‐wave 665, 730, 810, or 980 nm lasers (36 J/cm 2 delivered at 150 mW/cm 2) 4‐hour post‐TBI and were followed up by neurological performance testing for 4 weeks. Results: Mice with moderate‐to‐severe TBI treated with 665 and 810 nm laser (but not with 730 or 980 nm) had a significant improvement in Neurological Severity Score that increased over the course of the follow‐up compared to sham‐treated controls. Morphometry of brain sections showed a reduction in small deficits in 665 and 810 nm laser treated mouse brains at 28 days. Conclusions: The effectiveness of 810 nm agrees with previous publications, and together with the effectiveness of 660 nm and non‐effectiveness of 730 and 980 nm can be explained by the absorption spectrum of cytochrome oxidase, the candidate mitochondrial chromophore in transcranial LLLT. Lasers Surg. Med. 44:218–226, 2012. © 2012 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/lsm.22003

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 163

Metadata

Authors
Wu, Q., Xuan, W., Ando, T., Xu, T., Huang, L., Huang, Y., Dai, T., Dhital, S., Sharma, S. K., Whalen, M. J., & Hamblin, M. R.
Venue
Lasers in Surgery and Medicine
Publisher
Wiley
Published
2012-01-24
Volume
44
Issue
3
Pages
218-226
ISSN
  • 0196-8092 (ISSN-L)
  • 1096-9101
OpenAlex
W2145349262
Cited by
163
References
6
FWCI
7.79
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low‐Level Laser Therapy for Closed‐Head Traumatic Brain Injury in Mice: Effect of Different Wavelengths. https://app.cochat.ai/papers/10.1002/lsm.22003
The paper
Wu, Q., Xuan, W., Ando, T., Xu, T., Huang, L., Huang, Y., Dai, T., Dhital, S., Sharma, S. K., Whalen, M. J., & Hamblin, M. R. (2012). Low‐Level Laser Therapy for Closed‐Head Traumatic Brain Injury in Mice: Effect of Different Wavelengths. Lasers in Surgery and Medicine. https://doi.org/10.1002/lsm.22003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.