Biofunctionalized Hydrogel Microscaffolds Promote 3D Hepatic Sheet Morphology
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Development of artificial tissues providing the proper geometrical, mechanical, and environmental cues for cells is highly coveted in the field of tissue engineering. Recently, microfabrication strategies in combination with other chemistries have been utilized to capture the architectural complexity of intricate organs, such as the liver, in in vitro platforms. Here it is shown that a biofunctionalized poly (ethylene glycol) (PEG) hydrogel scaffold, fabricated using a sphere‐template, facilitates hepatic sheet formation that follows the microscale patterns of the scaffold surface. The design takes advantage of the excellent diffusion properties of porous, uniform 3D hydrogel platforms, and the enhanced‐cell–extracellular matrix interaction with the display of conjugated collagen type I, which in turn elicits favorable Huh‐7.5 response. Collectively, the experimental findings and corresponding simulations demonstrate the importance of biofunctionalized porous scaffolds and indicate that the microscaffold shows promise in liver tissue engineering applications and provides distinct advantages over current cell sheet and hepatocyte spheroid technologies. image
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT Method
Livak, K. J., & Schmittgen, T. D. (2001) · Methods · doi:10.1006/meth.2001.1262 · Cited by 180,860
Recent advances in three‐dimensional multicellular spheroid culture for biomedical research
Lin, R., & Chang, H. (2008) · Biotechnology Journal · doi:10.1002/biot.200700228 · Cited by 1,264
Three-Dimensional Cell Culture Matrices: State of the Art
Lee, J., Cuddihy, M. J., & Kotov, N. A. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/teb.2007.0150 · Cited by 1,047
Self-citationChang, T. T., & Hughes-Fulford, M. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2007.0434 · Cited by 311
Cited by
Advances in Engineering Human Tissue Models
Moysidou, C.-M., Barberio, C., & Owens, R. M. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.620962 · Cited by 179
Engineering 3D Hydrogels for Personalized In Vitro Human Tissue Models
Liaw, C., Ji, S., & Guvendiren, M. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701165 · Cited by 170
Ng, S. S., Saeb-Parsy, K., Blackford, S. J. I., Segal, J. M., Serra, M. P., Horcas-Lopez, M., No, D. Y., Mastoridis, S., Jassem, W., Frank, C. W., et al. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.07.043 · Cited by 133
Self-citationIntegrating Organs-on-Chips: Multiplexing, Scaling, Vascularization, and Innervation
Park, D., Lee, J., Chung, J. J., Jung, Y., & Kim, S. H. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2019.06.006 · Cited by 105
Self-citationLee, B. H., Shirahama, H., Kim, M. H., Lee, J. H., Cho, N.-J., & Tan, L. P. (2017) · NPG Asia Materials · doi:10.1038/am.2017.126 · Cited by 52
Self-citation
Metadata
- Authors
- Kim, M. H., Kumar, S. K., Shirahama, H., Seo, J., Lee, J., Zhdanov, V. P., & Cho, N.
- Venue
- Macromolecular Bioscience
- Publisher
- Wiley
- Published
- 2015-11-27
- Volume
- 16
- Issue
- 3
- Pages
- 314-321
- ISSN
- 1616-5187 (ISSN-L)
- 1616-5195
- OpenAlex
- W2174053609
- Cited by
- 21
- References
- 4
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.