The DOI matches its Crossref record; 90 of the 90 references it cites were found in a registry or an index.
Investigation of intact protein complexes by mass spectrometry
Open accessAbstract
I. Introduction 00 II. Electrospray Ionization of Biomacromolecules 00 III. Mass Analyzers for Biomacromolecular Mass Spectrometry 00 A. Collisional Cooling and/or Focusing 00 B. Alternative Mass Analyzers 00 IV. Solution‐Phase Properties of Proteins Complexes 00 A. Protein–Protein Interactions 00 B. Cooperativity and Cofactors 00 C. Dynamics of Assembly 00 V. Gas‐Phase Properties of Protein Complexes 00 A. Tandem Mass Spectrometry 00 B. Charge Separation in Protein Dissociation 00 VI. Future Outlook 00 Acknowledgments 00 References 00 Mass spectrometry has grown in recent years to a well‐accepted and increasingly important complementary technique in structural biology. Especially electrospray ionization mass spectrometry is well suited for the detection of non‐covalent protein complexes and their interactions with DNA, RNA, ligands, and cofactors. Over the last decade, significant advances have been made in the ionization and mass analysis techniques, which makes the investigation of even larger and more heterogeneous intact assemblies feasible. These technological developments have paved the way to study intact non‐covalent protein–protein interactions, assembly and disassembly in real time, subunit exchange, cooperativity effects, and effects of cofactors, allowing us a better understanding of proteins in cellular processes. In this review, we describe some of the latest developments and several highlights. © 2004 Wiley Periodicals, Inc., Mass Spec Rev
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometry
Tanaka, K., Waki, H., Ido, Y., Akita, S., Yoshida, Y., Yoshida, T., & Matsuo, T. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290020802 · Cited by 3,175
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
XX. On the equilibrium of liquid conducting masses charged with electricity
Rayleigh, L. (1882) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786448208628425 · Cited by 1,825
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Studying noncovalent protein complexes by electrospray ionization mass spectrometry
Loo, J. A. (1997) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1997)16:1<1::aid-mas1>3.0.co;2-l · Cited by 1,182
Cited by
Ion mobility–mass spectrometry analysis of large protein complexes
Ruotolo, B. T., Benesch, J. L. P., Sandercock, A. M., Hyung, S.-J., & Robinson, C. V. (2008) · Nature Protocols · doi:10.1038/nprot.2008.78 · Cited by 1,092
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Pringle, S. D., Giles, K., Wildgoose, J. L., Williams, J. P., Slade, S. E., Thalassinos, K., Bateman, R. H., Bowers, M. T., & Scrivens, J. H. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.07.021 · Cited by 808
Native mass spectrometry: a bridge between interactomics and structural biology
Heck, A. J. R. (2008) · Nature Methods · doi:10.1038/nmeth.1265 · Cited by 766
Self-citationUnraveling the Mechanism of Electrospray Ionization
Konermann, L., Ahadi, E., Rodriguez, A. D., & Vahidi, S. (2013) · Analytical Chemistry · doi:10.1021/ac302789c · Cited by 735
Towards single-molecule nanomechanical mass spectrometry
Naik, A. K., Hanay, M. S., Hiebert, W. K., Feng, X. L., & Roukes, M. L. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.152 · Cited by 683
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
“DNA [77], protein–drug [78], and protein–protein complexes [79, 80].”
Self-citationIon mobility mass spectrometry of proteins and proteinassemblies
Uetrecht, C., Rose, R. J., van Duijn, E., Lorenzen, K., & Heck, A. J. R. (2010) · Chem. Soc. Rev. · doi:10.1039/b914002f · Cited by 462
Self-citationBreuker, K., & McLafferty, F. W. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0807005105 · Cited by 423
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
Lapthorn, C., Pullen, F., & Chowdhry, B. Z. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21349 · Cited by 398
Electrospray mass spectrometry (ESI‐MS) in the study of metal–ligand solution equilibria
Di Marco, V. B., & Bombi, G. G. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20070 · Cited by 355
Estimates of Protein Surface Areas in Solution by Electrospray Ionization Mass Spectrometry
Kaltashov, I. A., & Mohimen, A. (2005) · Analytical Chemistry · doi:10.1021/ac050511+ · Cited by 319
Native protein mass spectrometry: from intact oligomers to functional machineries
Heuvel, R. H. V. D., & Heck, A. J. (2004) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2004.08.006 · Cited by 303
Self-citationStructure of an Hsp90-Cdc37-Cdk4 Complex
Vaughan, C. K., Gohlke, U., Sobott, F., Good, V. M., Ali, M. M. U., Prodromou, C., Robinson, C. V., Saibil, H. R., & Pearl, L. H. (2006) · Molecular Cell · doi:10.1016/j.molcel.2006.07.016 · Cited by 293
The Co-chaperone p23 Arrests the Hsp90 ATPase Cycle to Trap Client Proteins
McLaughlin, S. H., Sobott, F., Yao, Z.-P., Zhang, W., Nielsen, P. R., Grossmann, J. G., Laue, E. D., Robinson, C. V., & Jackson, S. E. (2006) · Journal of Molecular Biology · doi:10.1016/j.jmb.2005.11.085 · Cited by 196
Susa, A. C., Xia, Z., & Williams, E. R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04897 · Cited by 167
Norwalk Virus Assembly and Stability Monitored by Mass Spectrometry
Shoemaker, G. K., van Duijn, E., Crawford, S. E., Uetrecht, C., Baclayon, M., Roos, W. H., Wuite, G. J. L., Estes, M. K., Prasad, B. V. V., & Heck, A. J. R. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900620-mcp200 · Cited by 140
Self-citationVerrastro, I., Pasha, S., Jensen, K., Pitt, A., & Spickett, C. (2015) · Biomolecules · doi:10.3390/biom5020378 · Cited by 114
Biogenic manganese oxide nanoparticle formation by a multimeric multicopper oxidase Mnx
Romano, C. A., Zhou, M., Song, Y., Wysocki, V. H., Dohnalkova, A. C., Kovarik, L., Paša-Tolić, L., & Tebo, B. M. (2017) · Nature Communications · doi:10.1038/s41467-017-00896-8 · Cited by 102
Harper, C. C., Elliott, A. G., Oltrogge, L. M., Savage, D. F., & Williams, E. R. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01669 · Cited by 84
Native vs Denatured: An in Depth Investigation of Charge State and Isotope Distributions
Kafader, J. O., Melani, R. D., Schachner, L. F., Ives, A. N., Patrie, S. M., Kelleher, N. L., & Compton, P. D. (2020) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.9b00040 · Cited by 51
Standard Proteoforms and Their Complexes for Native Mass Spectrometry
Schachner, L. F., Ives, A. N., McGee, J. P., Melani, R. D., Kafader, J. O., Compton, P. D., Patrie, S. M., & Kelleher, N. L. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02191-w · Cited by 48
Konijnenberg, A., Bannwarth, L., Yilmaz, D., Koçer, A., Venien‐Bryan, C., & Sobott, F. (2015) · Protein Science · doi:10.1002/pro.2703 · Cited by 45
Mikhailov, V. A., Griffiths, R. L., & Cooper, H. J. (2017) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2016.09.011 · Cited by 41
“Native mass spectrometry is characterised by ions in relatively low charge states – fewer protonation sites are available in folded proteins – and thus higher mass-to-charge ratios are recorded (for gas-phase protein complexes typical m/z ≥ 3000) [1,2].”
BackgroundMethodIntrinsic GTPase activity of K-RAS monitored by native mass spectrometry
Moghadamchargari, Z., Huddleston, J., Shirzadeh, M., Zheng, X., Clemmer, D. E., M. Raushel, F., Russell, D. H., & Laganowsky, A. (2019) · Biochemistry · doi:10.1021/acs.biochem.9b00532 · Cited by 38
Shepherd, D. A., Holmes, K., Rowlands, D. J., Stonehouse, N. J., & Ashcroft, A. E. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.07.028 · Cited by 25
Metadata
- Authors
- Heck, A. J. R., & van den Heuvel, R. H. H.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2004-03-15
- Volume
- 23
- Issue
- 5
- Pages
- 368-389
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2083486056
- Cited by
- 583
- References
- 90
- FWCI
- 15.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.