The DOI matches its Crossref record; 154 of the 154 references it cites were found in a registry or an index.
Orbitrap mass spectrometry: Instrumentation, ion motion and applications
Abstract
Since its introduction, the orbitrap has proven to be a robust mass analyzer that can routinely deliver high resolving power and mass accuracy. Unlike conventional ion traps such as the Paul and Penning traps, the orbitrap uses only electrostatic fields to confine and to analyze injected ion populations. In addition, its relatively low cost, simple design and high space‐charge capacity make it suitable for tackling complex scientific problems in which high performance is required. This review begins with a brief account of the set of inventions that led to the orbitrap, followed by a qualitative description of ion capture, ion motion in the trap and modes of detection. Various orbitrap instruments, including the commercially available linear ion trap–orbitrap hybrid mass spectrometers, are also discussed with emphasis on the different methods used to inject ions into the trap. Figures of merit such as resolving power, mass accuracy, dynamic range and sensitivity of each type of instrument are compared. In addition, experimental techniques that allow mass‐selective manipulation of the motion of confined ions and their potential application in tandem mass spectrometry in the orbitrap are described. Finally, some specific applications are reviewed to illustrate the performance and versatility of the orbitrap mass spectrometers. © 2008 Wiley Periodicals, Inc., Mass Spec Rev 27: 661–699, 2008
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324
Self-citationVersatile New Ion Source for the Analysis of Materials in Open Air under Ambient Conditions
Cody, R. B., Laramée, J. A., & Durst, H. D. (2005) · Analytical Chemistry · doi:10.1021/ac050162j · Cited by 2,483
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Cited by
Global metabolic profiling procedures for urine using UPLC–MS
Want, E. J., Wilson, I. D., Gika, H., Theodoridis, G., Plumb, R. S., Shockcor, J., Holmes, E., & Nicholson, J. K. (2010) · Nature Protocols · doi:10.1038/nprot.2010.50 · Cited by 1,169
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Weiss, R. G. (2014) · Journal of the American Chemical Society · doi:10.1021/ja503363v · Cited by 672
Zubarev, R. A., & Makarov, A. (2013) · Analytical Chemistry · doi:10.1021/ac4001223 · Cited by 658
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
“Addressing these issues, an Orbitrap mass analyzer [51] modified for the transmission of ions in the highm/z range was introduced for nativeMS analysis in 2012 [52].”
MethodAdvances in structure elucidation of small molecules using mass spectrometry
Kind, T., & Fiehn, O. (2010) · Bioanalytical Reviews · doi:10.1007/s12566-010-0015-9 · Cited by 480
Sharifzadeh, M., Sadeqzadeh, M., Guo, M., Borhani, T. N., Murthy Konda, N. V. S. N., Garcia, M. C., Wang, L., Hallett, J., & Shah, N. (2019) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2018.10.006 · Cited by 473
Evolution of Orbitrap Mass Spectrometry Instrumentation
Eliuk, S., & Makarov, A. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040325 · Cited by 456
Mycotoxins in cereals and related foodstuffs: A review on occurrence and recent methods of analysis
Pereira, V. L., Fernandes, J. O., & Cunha, S. C. (2014) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2014.01.005 · Cited by 397
High-sensitivity Orbitrap mass analysis of intact macromolecular assemblies
Rose, R. J., Damoc, E., Denisov, E., Makarov, A., & Heck, A. J. R. (2012) · Nature Methods · doi:10.1038/nmeth.2208 · Cited by 392
Mass spectrometry‐based plant metabolomics: Metabolite responses to abiotic stress
Jorge, T. F., Rodrigues, J. A., Caldana, C., Schmidt, R., van Dongen, J. T., Thomas‐Oates, J., & António, C. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21449 · Cited by 376
Zhang, H., Zhang, D., Ray, K., & Zhu, M. (2009) · Journal of Mass Spectrometry · doi:10.1002/jms.1610 · Cited by 294
Metabolite Spectral Accuracy on Orbitraps
Su, X., Lu, W., & Rabinowitz, J. D. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00396 · Cited by 285
Current use of high-resolution mass spectrometry in the environmental sciences
Hernández, F., Sancho, J. V., Ibáñez, M., Abad, E., Portolés, T., & Mattioli, L. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5844-7 · Cited by 283
High Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281
Brown, M., Dunn, W. B., Dobson, P., Patel, Y., Winder, C. L., Francis-McIntyre, S., Begley, P., Carroll, K., Broadhurst, D., Tseng, A., et al. (2009) · The Analyst · doi:10.1039/b901179j · Cited by 269
Mucin‐type O‐glycosylation – putting the pieces together
Jensen, P. H., Kolarich, D., & Packer, N. H. (2010) · The FEBS Journal · doi:10.1111/j.1742-4658.2009.07429.x · Cited by 252
Top-down Proteomics: Technology Advancements and Applications to Heart Diseases
Cai, W., Tucholski, T. M., Gregorich, Z. R., & Ge, Y. (2016) · Expert Review of Proteomics · doi:10.1080/14789450.2016.1209414 · Cited by 99
Melani, R. D., Skinner, O. S., Fornelli, L., Domont, G. B., Compton, P. D., & Kelleher, N. L. (2016) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m115.056523 · Cited by 85
Standard Proteoforms and Their Complexes for Native Mass Spectrometry
Schachner, L. F., Ives, A. N., McGee, J. P., Melani, R. D., Kafader, J. O., Compton, P. D., Patrie, S. M., & Kelleher, N. L. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02191-w · Cited by 48
Extending the Isotopically Resolved Mass Range of Orbitrap Mass Spectrometers
Shaw, J. B., & Brodbelt, J. S. (2013) · Analytical Chemistry · doi:10.1021/ac401634b · Cited by 28
Metadata
- Authors
- Perry, R. H., Cooks, R. G., & Noll, R. J.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2008-08-06
- Volume
- 27
- Issue
- 6
- Pages
- 661-699
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2053849622
- Cited by
- 514
- References
- 154
- FWCI
- 13.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.