The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
The ion funnel: Theory, implementations, and applications
Open accessAbstract
The electrodynamic ion funnel has enabled the manipulation and focusing of ions in a pressure regime (0.1–30 Torr) that has challenged traditional approaches, and provided the basis for much greater mass spectrometer ion transmission efficiencies. The initial ion funnel implementations aimed to efficiently capture ions in the expanding gas jet of an electrospray ionization interface and radially focus them for efficient transfer through a conductance limiting orifice. We review the improvements in fundamental understanding of ion motion in ion funnels, the evolution in its implementations that have brought the ion funnel to its current state of refinement, as well as applications of the ion funnel for purposes such as ion trapping, ion cooling, low pressure electrospray, and ion mobility spectrometry. © 2009 Wiley Periodicals, Inc., Mass Spec Rev 29:294–312, 2010
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974
Radiofrequency Spectroscopy of Stored Ions I: Storage
Dehmelt, H. G. (1968) · Advances in Atomic and Molecular Physics · doi:10.1016/s0065-2199(08)60170-0 · Cited by 765
Inhomogeneous RF Fields: A Versatile Tool for the Study of Processes with Slow Ions
Gerlich, D. (1992) · Advances in Chemical Physics · doi:10.1002/9780470141397.ch1 · Cited by 685
Schmidt, A., Karas, M., & Dülcks, T. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00128-4 · Cited by 534
[22] Electrospray ionization mass spectrometry
Edmonds, C. G., & Smith, R. D. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93430-s · Cited by 508
Self-citationState-Selected and State-to-State Ion−Molecule Reaction Dynamics
Ng, C.-Y. (2002) · The Journal of Physical Chemistry A · doi:10.1021/jp020055i · Cited by 429
Radiofrequency Spectroscopy of Stored Ions II: Spectroscopy
Dehmelt, H. G. (1969) · Advances in Atomic and Molecular Physics · doi:10.1016/s0065-2199(08)60156-6 · Cited by 295
Design of a new electrospray ion mobility mass spectrometer
Wyttenbach, T., Kemper, P. R., & Bowers, M. T. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00517-6 · Cited by 277
Koeniger, S. L., Merenbloom, S. I., Valentine, S. J., Jarrold, M. F., Udseth, H. R., Smith, R. D., & Clemmer, D. E. (2006) · Analytical Chemistry · doi:10.1021/ac051060w · Cited by 272
Self-citationShaffer, S. A., Prior, D. C., Anderson, G. A., Udseth, H. R., & Smith, R. D. (1998) · Analytical Chemistry · doi:10.1021/ac9802170 · Cited by 262
Self-citationSchaffer, S. A., Tang, K., Anderson, G. A., Prior, D. C., Udseth, H. R., & Smith, R. D. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19971030)11:16<1813::aid-rcm87>3.0.co;2-d · Cited by 262
Self-citationKelly, R. T., Page, J. S., Luo, Q., Moore, R. J., Orton, D. J., Tang, K., & Smith, R. D. (2006) · Analytical Chemistry · doi:10.1021/ac061133r · Cited by 240
Self-citationDesign and Implementation of a New Electrodynamic Ion Funnel
Kim, T., Tolmachev, A. V., Harkewicz, R., Prior, D. C., Anderson, G., Udseth, H. R., Smith, R. D., Bailey, T. H., Rakov, S., & Futrell, J. H. (2000) · Analytical Chemistry · doi:10.1021/ac991412x · Cited by 201
Self-citationIMS−IMS and IMS−IMS−IMS/MS for Separating Peptide and Protein Fragment Ions
Merenbloom, S. I., Koeniger, S. L., Valentine, S. J., Plasencia, M. D., & Clemmer, D. E. (2006) · Analytical Chemistry · doi:10.1021/ac052208e · Cited by 200
Small volume and low flow‐rate electrospray lonization mass spectrometry of aqueous samples
Gale, D. C., & Smith, R. D. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290071111 · Cited by 176
Self-citationBelov, M. E., Gorshkov, M. V., Udseth, H. R., Anderson, G. A., & Smith, R. D. (2000) · Analytical Chemistry · doi:10.1021/ac991360b · Cited by 164
Self-citationSmith, R. D., Shen, Y., & Tang, K. (2004) · Accounts of Chemical Research · doi:10.1021/ar0301330 · Cited by 146
Self-citationBaker, E. S., Clowers, B. H., Li, F., Tang, K., Tolmachev, A. V., Prior, D. C., Belov, M. E., & Smith, R. D. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.03.031 · Cited by 143
Self-citationGidden, J. A., Ferzoco, A., Baker, E. S., & Bowers, M. T. (2004) · Journal of the American Chemical Society · doi:10.1021/ja046433+ · Cited by 118
Clowers, B. H., Ibrahim, Y., Prior, D. C., Danielson, W., Belov, M. E., & Smith, R. D. (2008) · Analytical Chemistry · doi:10.1021/ac701648p · Cited by 116
Self-citationCarl, D. R., Moision, R. M., & Armentrout, P. B. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.03.008 · Cited by 115
Structural motifs of DNA complexes in the gas phase
Gidden, J. A., Baker, E. S., Ferzoco, A., & Bowers, M. T. (2004) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.09.011 · Cited by 111
Accurate Mass Measurements in Proteomics
Liu, T., Belov, M. E., Jaitly, N., Qian, W., & Smith, R. D. (2007) · Chemical Reviews · doi:10.1021/cr068288j · Cited by 109
Self-citationHannis, J. C., & Muddiman, D. C. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00160-4 · Cited by 105
State-selected and state-to-state ion—molecule reaction dynamics. Part 1. Experiment
Whitaker, B. (1992) · Chemical Engineering Science · doi:10.1016/0009-2509(92)85129-y · Cited by 104
Tolmachev, A. V., Kim, T., Udseth, H. R., Smith, R. D., Bailey, T. H., & Futrell, J. H. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00265-7 · Cited by 102
Self-citationTowards direct mass measurements of nobelium at SHIPTRAP
Block, M., Ackermann, D., Blaum, K., et al. (2007) · The European Physical Journal D · doi:10.1140/epjd/e2007-00189-2 · Cited by 102
Scale-up of electrospray atomization using linear arrays of Taylor cones
Rulison, A. J., & Flagan, R. C. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144197 · Cited by 100
Improving mass spectrometer sensitivity using a high-pressure electrodynamic ion funnel interface
Ibrahim, Y., Tang, K., Tolmachev, A. V., Shvartsburg, A. A., & Smith, R. D. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.06.005 · Cited by 100
Self-citationCollision cross sections of myoglobin and cytochrome c ions with Ne, Ar, and Kr
Chen, Y., Collings, B. A., & Douglascor, D. J. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00033-0 · Cited by 98
Volný, M., Elam, W. T., Branca, A., Ratner, B. D., & Tureček, F. (2005) · Analytical Chemistry · doi:10.1021/ac0507136 · Cited by 92
Page, J. S., Tang, K., Kelly, R., & Smith, R. D. (2008) · Analytical Chemistry · doi:10.1021/ac702354b · Cited by 87
Self-citationPNA/dsDNA Complexes: Site Specific Binding and dsDNA Biosensor Applications
Baker, E. S., Hong, J. W., Gaylord, B. S., Bazan, G. C., & Bowers, M. T. (2006) · Journal of the American Chemical Society · doi:10.1021/ja060069s · Cited by 85
Belov, M. E., Gorshkov, M. V., Udseth, H. R., Anderson, G., Tolmachev, A. V., Prior, D. C., Harkewicz, R., & Smith, R. D. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00121-x · Cited by 79
Self-citationKelly, R., Page, J. S., Zhao, R., Qian, W., Mottaz, H. M., Tang, K., & Smith, R. D. (2007) · Analytical Chemistry · doi:10.1021/ac701647s · Cited by 74
Self-citationLiu, D., Wyttenbach, T., & Bowers, M. T. (2006) · Journal of the American Chemical Society · doi:10.1021/ja062418o · Cited by 58
Kelly, R., Page, J. S., Tang, K., & Smith, R. D. (2007) · Analytical Chemistry · doi:10.1021/ac062417e · Cited by 58
Self-citationFlora, J. W., Hannis, J. C., & Muddiman, D. C. (2001) · Analytical Chemistry · doi:10.1021/ac0011282 · Cited by 51
Page, J. S., Bogdanov, B., Vilkov, A. N., Prior, D. C., Buschbach, M. A., Tang, K., & Smith, R. D. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.11.003 · Cited by 48
Self-citationJones, J. W., Sasaki, T., Goodlett, D. R., & Tureček, F. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.10.005 · Cited by 37
Automated Gain Control Ion Funnel Trap for Orthogonal Time-of-Flight Mass Spectrometry
Ibrahim, Y., Belov, M. E., Liyu, A. V., & Smith, R. D. (2008) · Analytical Chemistry · doi:10.1021/ac8003488 · Cited by 35
Self-citationPerformance of the MLL-IonCatcher
Neumayr, J. B., Thirolf, P. G., Habs, D., Heinz, S., Kolhinen, V. S., Sewtz, M., & Szerypo, J. (2006) · Review of Scientific Instruments · doi:10.1063/1.2213154 · Cited by 34
Mass measurements in the endpoint region of the rp-process at SHIPTRAP
Block, M., Ackermann, D., Blaum, K., et al. (2006) · Hyperfine Interactions · doi:10.1007/s10751-007-9550-3 · Cited by 13
Cited by
Proton-Transfer-Reaction Mass Spectrometry: Applications in Atmospheric Sciences
Yuan, B., Koss, A. R., Warneke, C., Coggon, M., Sekimoto, K., & de Gouw, J. A. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00325 · Cited by 606
Zhu, Y., Piehowski, P. D., Zhao, R., Chen, J., Shen, Y., Moore, R. J., Shukla, A. K., Petyuk, V. A., Campbell-Thompson, M., Mathews, C. E., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03367-w · Cited by 587
Self-citationEvolution of Orbitrap Mass Spectrometry Instrumentation
Eliuk, S., & Makarov, A. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040325 · Cited by 456
Mass spectrometry-based proteomics: existing capabilities and future directions
Angel, T. E., Aryal, U. K., Hengel, S. M., Baker, E. S., Kelly, R. T., Robinson, E. W., & Smith, R. D. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15331a · Cited by 441
Self-citationFundamentals of Trapped Ion Mobility Spectrometry
Michelmann, K., Silveira, J. A., Ridgeway, M. E., & Park, M. A. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-0999-4 · Cited by 374
Metadata
- Authors
- Kelly, R. T., Tolmachev, A. V., Page, J. S., Tang, K., & Smith, R. D.
- Venue
- Mass Spectrometry Reviews
- Publisher
- Wiley
- Published
- 2009-04-23
- Volume
- 29
- Issue
- 2
- Pages
- 294-312
- ISSN
- 0277-7037 (ISSN-L)
- 1098-2787
- OpenAlex
- W2031597060
- Cited by
- 280
- References
- 45
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.