Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 190

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Deeply supervised 3D fully convolutional networks with group dilated convolution for automatic MRI prostate segmentation

Open access
Wang, Bo, Lei, Yang, Tian, Sibo, Wang, Tonghe, Liu, Yingzi, Patel, Pretesh, Jani, Ashesh B., Mao, Hui, Curran, Walter J., Liu, Tian, Yang, Xiaofeng · 2019 · Medical Physics

Abstract

Purpose: Reliable automated segmentation of the prostate is indispensable for image‐guided prostate interventions. However, the segmentation task is challenging due to inhomogeneous intensity distributions, variation in prostate anatomy, among other problems. Manual segmentation can be time‐consuming and is subject to inter‐ and intraobserver variation. We developed an automated deep learning‐based method to address this technical challenge. Methods: We propose a three‐dimensional (3D) fully convolutional networks (FCN) with deep supervision and group dilated convolution to segment the prostate on magnetic resonance imaging (MRI). In this method, a deeply supervised mechanism was introduced into a 3D FCN to effectively alleviate the common exploding or vanishing gradients problems in training deep models, which forces the update process of the hidden layer filters to favor highly discriminative features. A group dilated convolution which aggregates multiscale contextual information for dense prediction was proposed to enlarge the effective receptive field of convolutional neural networks, which improve the prediction accuracy of prostate boundary. In addition, we introduced a combined loss function including cosine and cross entropy, which measures similarity and dissimilarity between segmented and manual contours, to further improve the segmentation accuracy. Prostate volumes manually segmented by experienced physicians were used as a gold standard against which our segmentation accuracy was measured. Results: The proposed method was evaluated on an internal dataset comprising 40 T2‐weighted prostate MR volumes. Our method achieved a Dice similarity coefficient (DSC) of 0.86 ± 0.04, a mean surface distance (MSD) of 1.79 ± 0.46 mm, 95% Hausdorff distance (95%HD) of 7.98 ± 2.91 mm, and absolute relative volume difference (aRVD) of 15.65 ± 10.82. A public dataset (PROMISE 12) including 50 T2‐weighted prostate MR volumes was also employed to evaluate our approach. Our method yielded a DSC of 0.88 ± 0.05, MSD of 1.02 ± 0.35 mm, 95% HD of 9.50 ± 5.11 mm, and aRVD of 8.93 ± 7.56. Conclusion: We developed a novel deeply supervised deep learning‐based approach with a group dilated convolution to automatically segment the MRI prostate, demonstrated its clinical feasibility, and validated its accuracy against manual segmentation. The proposed technique could be a useful tool for image‐guided interventions in prostate cancer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.13416

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Wang, B., Lei, Y., Tian, S., Wang, T., Liu, Y., Patel, P., Jani, A. B., Mao, H., Curran, W. J., Liu, T., & Yang, X.
Venue
Medical Physics
Publisher
Wiley
Published
2019-02-19
Volume
46
Issue
4
Pages
1707-1718
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2914806156
Cited by
190
References
6
FWCI
14.08
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.