CoChat

LungRegNet: An unsupervised deformable image registration method for 4D‐CT lung

Open access
Fu, Yabo, Lei, Yang, Wang, Tonghe, Higgins, Kristin, Bradley, Jeffrey D., Curran, Walter J., Liu, Tian, Yang, Xiaofeng · 2020 · Medical Physics
Cited by 131

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Purpose: To develop an accurate and fast deformable image registration (DIR) method for four‐dimensional computed tomography (4D‐CT) lung images. Deep learning‐based methods have the potential to quickly predict the deformation vector field (DVF) in a few forward predictions. We have developed an unsupervised deep learning method for 4D‐CT lung DIR with excellent performances in terms of registration accuracies, robustness, and computational speed. Methods: A fast and accurate 4D‐CT lung DIR method, namely LungRegNet, was proposed using deep learning. LungRegNet consists of two subnetworks which are CoarseNet and FineNet. As the name suggests, CoarseNet predicts large lung motion on a coarse scale image while FineNet predicts local lung motion on a fine scale image. Both the CoarseNet and FineNet include a generator and a discriminator. The generator was trained to directly predict the DVF to deform the moving image. The discriminator was trained to distinguish the deformed images from the original images. CoarseNet was first trained to deform the moving images. The deformed images were then used by the FineNet for FineNet training. To increase the registration accuracy of the LungRegNet, we generated vessel‐enhanced images by generating pulmonary vasculature probability maps prior to the network prediction. Results: We performed fivefold cross validation on ten 4D‐CT datasets from our department. To compare with other methods, we also tested our method using separate 10 DIRLAB datasets that provide 300 manual landmark pairs per case for target registration error (TRE) calculation. Our results suggested that LungRegNet has achieved better registration accuracy in terms of TRE than other deep learning‐based methods available in the literature on DIRLAB datasets. Compared to conventional DIR methods, LungRegNet could generate comparable registration accuracy with TRE smaller than 2 mm. The integration of both the discriminator and pulmonary vessel enhancements into the network was crucial to obtain high registration accuracy for 4D‐CT lung DIR. The mean and standard deviation of TRE were 1.00 ± 0.53 mm and 1.59 ± 1.58 mm on our datasets and DIRLAB datasets respectively. Conclusions: An unsupervised deep learning‐based method has been developed to rapidly and accurately register 4D‐CT lung images. LungRegNet has outperformed its deep‐learning‐based peers and achieved excellent registration accuracy in terms of TRE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mp.14065

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 131

Metadata

Authors
Fu, Y., Lei, Y., Wang, T., Higgins, K., Bradley, J. D., Curran, W. J., Liu, T., & Yang, X.
Venue
Medical Physics
Publisher
Wiley
Published
2020-02-26
Volume
47
Issue
4
Pages
1763-1774
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W3004561498
Cited by
131
References
5
FWCI
12.93
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.