LungRegNet: An unsupervised deformable image registration method for 4D‐CT lung
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Purpose: To develop an accurate and fast deformable image registration (DIR) method for four‐dimensional computed tomography (4D‐CT) lung images. Deep learning‐based methods have the potential to quickly predict the deformation vector field (DVF) in a few forward predictions. We have developed an unsupervised deep learning method for 4D‐CT lung DIR with excellent performances in terms of registration accuracies, robustness, and computational speed. Methods: A fast and accurate 4D‐CT lung DIR method, namely LungRegNet, was proposed using deep learning. LungRegNet consists of two subnetworks which are CoarseNet and FineNet. As the name suggests, CoarseNet predicts large lung motion on a coarse scale image while FineNet predicts local lung motion on a fine scale image. Both the CoarseNet and FineNet include a generator and a discriminator. The generator was trained to directly predict the DVF to deform the moving image. The discriminator was trained to distinguish the deformed images from the original images. CoarseNet was first trained to deform the moving images. The deformed images were then used by the FineNet for FineNet training. To increase the registration accuracy of the LungRegNet, we generated vessel‐enhanced images by generating pulmonary vasculature probability maps prior to the network prediction. Results: We performed fivefold cross validation on ten 4D‐CT datasets from our department. To compare with other methods, we also tested our method using separate 10 DIRLAB datasets that provide 300 manual landmark pairs per case for target registration error (TRE) calculation. Our results suggested that LungRegNet has achieved better registration accuracy in terms of TRE than other deep learning‐based methods available in the literature on DIRLAB datasets. Compared to conventional DIR methods, LungRegNet could generate comparable registration accuracy with TRE smaller than 2 mm. The integration of both the discriminator and pulmonary vessel enhancements into the network was crucial to obtain high registration accuracy for 4D‐CT lung DIR. The mean and standard deviation of TRE were 1.00 ± 0.53 mm and 1.59 ± 1.58 mm on our datasets and DIRLAB datasets respectively. Conclusions: An unsupervised deep learning‐based method has been developed to rapidly and accurately register 4D‐CT lung images. LungRegNet has outperformed its deep‐learning‐based peers and achieved excellent registration accuracy in terms of TRE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jaderberg, M., Simonyan, K., Zisserman, A., & Kavukcuoglu, K. (2015) · arXiv · doi:10.48550/arxiv.1506.02025 · Cited by 5,137
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587 · cited 2×
“Conventional DIR methods usually require careful parameter tuning to maximize its performance, which depends on the image similarity metrics used, registration anatomical sites and imaging modalities 6 .”
BackgroundMethodBrock, K. K., Mutic, S., McNutt, T. R., Li, H., & Kessler, M. L. (2017) · Medical Physics · doi:10.1002/mp.12256 · Cited by 881 · cited 1×
“Deformable image registration (DIR) of 4D-CT lung images is important in multiple radiation therapy applications including lung motion tracking 1 , target definition 2 , image fusion 3 , gated treatment planning 4 and treatment response evaluations 5 .”
BackgroundDeep learning in medical image registration: a review
Fu, Y., Lei, Y., Wang, T., Curran, W. J., Liu, T., & Yang, X. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab843e · Cited by 661 · cited 1×
“Deep learning-based DIR methods have been proposed for MRI brain 21 , CT head/neck 22 , CT chest 23 , MR/US prostate 24 , 4D-CT lung 25–28 and so on 29 .”
MethodSelf-citationAdversarial Image Registration with Application for MR and TRUS Image Fusion
Yan, P., Xu, S., Rastinehad, A. R., & Wood, B. J. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-00919-9_23 · Cited by 100
Cited by
Deep learning in medical image registration: a review
Fu, Y., Lei, Y., Wang, T., Curran, W. J., Liu, T., & Yang, X. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab843e · Cited by 661
“[48] Lung 3D-3D Yes CT Deformable [102, 103, 104] Retina, Cardiac 2D-2D No FA, Xray Deformable”
BackgroundMethodSelf-citationDeep Learning for Medical Image-Based Cancer Diagnosis
Jiang, X., Hu, Z., Wang, S., & Zhang, Y. (2023) · Cancers · doi:10.3390/cancers15143608 · Cited by 345
A review of deep learning based methods for medical image multi-organ segmentation
Fu, Y., Lei, Y., Wang, T., Curran, W. J., Liu, T., & Yang, X. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.05.003 · Cited by 270
Self-citationMedical image registration using deep neural networks: A comprehensive review
Boveiri, H. R., Khayami, R., Javidan, R., & Mehdizadeh, A. (2020) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2020.106767 · Cited by 179
Deep Learning in Medical Image Registration
Chen, X., Diaz-Pinto, A., Ravikumar, N., & Frangi, A. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/abd37c · Cited by 106
A review of deep learning-based three-dimensional medical image registration methods
Xiao, H., Teng, X., Liu, C., Li, T., Ren, G., Yang, R., Shen, D., & Cai, J. (2021) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-21-175 · Cited by 77
Metadata
- Authors
- Fu, Y., Lei, Y., Wang, T., Higgins, K., Bradley, J. D., Curran, W. J., Liu, T., & Yang, X.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2020-02-26
- Volume
- 47
- Issue
- 4
- Pages
- 1763-1774
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W3004561498
- Cited by
- 131
- References
- 5
- FWCI
- 12.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.