The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Assessment of hepatic perfusion parameters with dynamic MRI
Open accessAbstract
Quantification of hepatic perfusion parameters greatly contributes to the assessment of liver function. The purpose of this study was to describe and validate the use of dynamic MRI for the noninvasive assessment of hepatic perfusion parameters. The signal from a fast T1‐weighted spoiled gradient‐echo sequence preceded by a nonslice‐selective 90° pulse and a spoiler gradient was calibrated in vitro with tubes filled with various gadolinium concentrations. Dynamic images of the liver were obtained after intravenous bolus administration of 0.05 mmol/kg of Gd‐DOTA in rabbits with normal liver function. Hepatic, aortic, and portal venous signal intensities were converted to Gd‐DOTA concentrations according to the in vitro calibration curve and fitted with a dual‐input one‐compartmental model. With MRI, hepatic blood flow was 100 ± 35 mL min‐1 100 mL‐1, the arterial fraction 24 ± 11%, the distribution volume 13.0 ± 3.7%, and the mean transit time 8.9 ± 4.1 sec. A linear relationship was observed between perfusion values obtained with MRI and with radiolabeled microspheres (r = 0.93 for hepatic blood flow [P < 0.001], r = 0.79 for arterial blood flow [P = 0.01], and r = 0.91 for portal blood flow [P < 0.001]). Our results indicate that hepatic perfusion parameters can be assessed with dynamic MRI and compartmental modeling. Magn Reson Med 47:135–142, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Cited by
Classic models for dynamic contrast‐enhanced MRI
Sourbron, S. P., & Buckley, D. L. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2940 · Cited by 434
Primovist, Eovist: What to expect?
Van Beers, B. E., Pastor, C. M., & Hussain, H. K. (2012) · Journal of Hepatology · doi:10.1016/j.jhep.2012.01.031 · Cited by 407
Self-citationPatel, J., Sigmund, E. E., Rusinek, H., Oei, M., Babb, J. S., & Taouli, B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22081 · Cited by 371
On the scope and interpretation of the Tofts models for DCE‐MRI
Sourbron, S. P., & Buckley, D. L. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22861 · Cited by 371
Tracer kinetic modelling in MRI: estimating perfusion and capillary permeability
Sourbron, S. P., & Buckley, D. L. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/2/r1 · Cited by 361
Perfusion and vascular permeability: Basic concepts and measurement in DCE-CT and DCE-MRI
Cuenod, C. A., & Balvay, D. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.10.010 · Cited by 312
Annet, L., Materne, R., Danse, E., Jamart, J., Horsmans, Y., & Van Beers, B. E. (2003) · Radiology · doi:10.1148/radiol.2292021128 · Cited by 295
Self-citationPerfusion Imaging of the Liver: Current Challenges and Future Goals
Pandharipande, P. V., Krinsky, G. A., Rusinek, H., & Lee, V. S. (2005) · Radiology · doi:10.1148/radiol.2343031362 · Cited by 294
Fibrosis in chronic liver diseases: diagnosis and management
Pinzani, M., Rombouts, K., & Colagrande, S. (2005) · Journal of Hepatology · doi:10.1016/j.jhep.2004.12.008 · Cited by 267
Diffusion-weighted magnetic resonance imaging for the assessment of fibrosis in chronic hepatitis C
Lewin, M., Poujol-Robert, A., Boëlle, P.-Y., Wendum, D., Lasnier, E., Viallon, M., Guéchot, J., Hoeffel, C., Arrivé, L., Tubiana, J.-M., et al. (2007) · Hepatology · doi:10.1002/hep.21747 · Cited by 265
Perfusion Magnetic Resonance Imaging: A Comprehensive Update on Principles and Techniques
Jahng, G.-H., Li, K.-L., Ostergaard, L., & Calamante, F. (2014) · Korean Journal of Radiology · doi:10.3348/kjr.2014.15.5.554 · Cited by 256
Bane, O., Hectors, S. J., Wagner, M., Arlinghaus, L. L., Aryal, M. P., Cao, Y., Chenevert, T. L., Fennessy, F., Huang, W., Hylton, N. M., et al. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26903 · Cited by 109
Anatomy of rodent and human livers: What are the differences?
Kruepunga, N., Hakvoort, T. B. M., Hikspoors, J. P. J. M., Köhler, S. E., & Lamers, W. H. (2019) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/j.bbadis.2018.05.019 · Cited by 79
Metadata
- Authors
- Materne, R., Smith, A. M., Peeters, F., Dehoux, J. P., Keyeux, A., Horsmans, Y., & Van Beers, B. E.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2001-12-20
- Volume
- 47
- Issue
- 1
- Pages
- 135-142
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1987512176
- Cited by
- 226
- References
- 1
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.