The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
On the scope and interpretation of the Tofts models for DCE‐MRI
Abstract
The Tofts model (TM) and extended Tofts model (ETM) have become a standard for the analysis of dynamic contrast‐enhanced MRI. In this study, a mathematical analysis is used to identify exactly in which tissue types the Tofts models may be applied. The results show that the TM is accurate if and only if the tissue is weakly vascularised (small blood volume). The ETM is additionally accurate in highly perfused tissues (high blood flow). In tissues that are highly vascularised, or where tracer exchange is very fast or very slow, TM and ETM accurately fit the data but lead to a misinterpretation of the parameters. In tissue types with intermediate vascularity, perfusion and tracer exchange, neither model offers a good fit to the tissue concentrations. A good fit can be obtained with a measured input function by reducing the temporal resolution, but this does not improve the accuracy of the parameters. In conclusion, the Tofts models only produce reliable parameter values if the tissue is weakly vascularized (TM or ETM) or highly perfused (ETM). Without prior knowledge that at least one of these constraints is fulfilled, the physiological interpretation of the values produced by the Tofts models is unclear. Magn Reson Med, 2011. © 2011 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data
Patlak, C. S., Blasberg, R. G., & Fenstermacher, J. D. (1983) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1983.1 · Cited by 3,567
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Self-citationModeling tracer kinetics in dynamic Gd‐DTPA MR imaging
Tofts, P. S. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070113 · Cited by 1,478
Compartmental analysis in Biology and Medicine
Anderson, D. H. (1986) · Mathematical Biosciences · doi:10.1016/0025-5564(86)90168-9 · Cited by 988
Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscles
Renkin, E. M. (1959) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1959.197.6.1205 · Cited by 723
Parker, G. J. M., Roberts, C., Macdonald, A., Buonaccorsi, G. A., Cheung, S., Buckley, D. L., Jackson, A., Watson, Y., Davies, K., & Jayson, G. C. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21066 · Cited by 660
Self-citationLeach, M. O., Brindle, K. M., Evelhoch, J. L., Griffiths, J. R., Horsman, M. R., Jackson, A., Jayson, G. C., Judson, I. R., Knopp, M. V., Maxwell, R. J., et al. (2005) · British Journal of Cancer · doi:10.1038/sj.bjc.6602550 · Cited by 513
Tracer kinetic methods in medical physiology
Lassen, N. A., & Perl, W. (1979) · Raven Press eBooks · Cited by 495
Functional tumor imaging with dynamic contrast‐enhanced magnetic resonance imaging
Choyke, P. L., Dwyer, A. J., & Knopp, M. V. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10304 · Cited by 439
Larsson, H. B. W., Stubgaard, M., Frederiksen, J. L., Jensen, M., Henriksen, O., & Paulson, O. B. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160111 · Cited by 431
Cited by
Classic models for dynamic contrast‐enhanced MRI
Sourbron, S. P., & Buckley, D. L. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2940 · Cited by 434
Self-citationHeye, A. K., Culling, R. D., Valdés Hernández, M. D. C., Thrippleton, M. J., & Wardlaw, J. M. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.09.002 · Cited by 406
Tracer kinetic modelling in MRI: estimating perfusion and capillary permeability
Sourbron, S. P., & Buckley, D. L. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/2/r1 · Cited by 361
Self-citationPerfusion and vascular permeability: Basic concepts and measurement in DCE-CT and DCE-MRI
Cuenod, C. A., & Balvay, D. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.10.010 · Cited by 312
Brain imaging of neurovascular dysfunction in Alzheimer’s disease
Montagne, A., Nation, D. A., Pa, J., Sweeney, M. D., Toga, A. W., & Zlokovic, B. V. (2016) · Acta Neuropathologica · doi:10.1007/s00401-016-1570-0 · Cited by 239
Metadata
- Authors
- Sourbron, S. P., & Buckley, D. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-03-07
- Volume
- 66
- Issue
- 3
- Pages
- 735-745
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2070772485
- Cited by
- 371
- References
- 33
- FWCI
- 18.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the scope and interpretation of the Tofts models for DCE‐MRI. https://app.cochat.ai/papers/10.1002/mrm.22861
- The paper
- Sourbron, S. P., & Buckley, D. L. (2011). On the scope and interpretation of the Tofts models for DCE‐MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22861
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.