The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Correction of physiologically induced global off‐resonance effects in dynamic echo‐planar and spiral functional imaging
Open accessAbstract
In functional magnetic resonance imaging, a rapid method such as echo‐planar (EPI) or spiral is used to collect a dynamic series of images. These techniques are sensitive to changes in resonance frequency which can arise from respiration and are more significant at high magnetic fields. To decrease the noise from respiration‐induced phase and frequency fluctuations, a simple correction of the “dynamic off‐resonance in k‐space” (DORK) was developed. The correction uses phase information from the center of k‐space and a navigator echo and is illustrated with dynamic scans of single‐shot and segmented EPI and, for the first time, spiral imaging of the human brain at 7 T. Image noise in the respiratory spectrum was measured with an edge operator. The DORK correction significantly reduced respiration‐induced noise (image shift for EPI, blurring for spiral, ghosting for segmented acquisition). While spiral imaging was found to exhibit less noise than EPI before correction, the residual noise after the DORK correction was comparable. The correction is simple to apply and can correct for other sources of frequency drift and fluctuations in dynamic imaging. Magn Reson Med 47:344–353, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Cited by
A component based noise correction method (CompCor) for BOLD and perfusion based fMRI
Behzadi, Y., Restom, K., Liau, J., & Liu, T. T. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.04.042 · Cited by 4,502
Time–frequency dynamics of resting-state brain connectivity measured with fMRI
Chang, C., & Glover, G. H. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.12.011 · Cited by 1,808
Self-citationMoeller, S., Yacoub, E., Olman, C. A., Auerbach, E., Strupp, J., Harel, N., & Uğurbil, K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22361 · Cited by 1,586
Self-citationThe neural basis of the blood–oxygen–level–dependent functional magnetic resonance imaging signal
Logothetis, N. K. (2002) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2002.1114 · Cited by 958
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Self-citationInfluence of heart rate on the BOLD signal: The cardiac response function
Chang, C., Cunningham, J. P., & Glover, G. H. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.029 · Cited by 667
Self-citationTriantafyllou, C., Hoge, R. D., Krueger, G., Wiggins, C. J., Potthast, A., Wiggins, G. C., & Wald, L. L. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.007 · Cited by 648
Shmuel, A., Yacoub, E., Pfeuffer, J., Van de Moortele, P.-F., Adriany, G., Hu, X., & Ugurbil, K. (2002) · Neuron · doi:10.1016/s0896-6273(02)01061-9 · Cited by 631
Self-citationMethods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
Evaluation of slice accelerations using multiband echo planar imaging at 3T
Xu, J., Moeller, S., Auerbach, E. J., Strupp, J., Smith, S. M., Feinberg, D. A., Yacoub, E., & Uğurbil, K. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.055 · Cited by 514
Chang, C., & Glover, G. H. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.012 · Cited by 488
Self-citationFrontal circuitry degradation marks healthy adult aging: Evidence from diffusion tensor imaging
Pfefferbaum, A., Adalsteinsson, E., & Sullivan, E. V. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.034 · Cited by 355
Cohen, E. R., Ugurbil, K., & Kim, S.-G. (2002) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200209000-00002 · Cited by 354
Self-citationYacoub, E., Shmuel, A., Logothetis, N., & Uğurbil, K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.05.020 · Cited by 308
Spatio-temporal point-spread function of fMRI signal in human gray matter at 7 Tesla
Shmuel, A., Yacoub, E., Chaimow, D., Logothetis, N. K., & Ugurbil, K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.12.030 · Cited by 294
Relationship between respiration, end-tidal CO2, and BOLD signals in resting-state fMRI
Chang, C., & Glover, G. H. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.04.048 · Cited by 292
Self-citationSullivan, E. V., Adalsteinsson, E., & Pfefferbaum, A. (2006) · Cerebral Cortex · doi:10.1093/cercor/bhj045 · Cited by 280
Noise Reduction in BOLD-Based fMRI Using Component Analysis
Thomas, C. G., Harshman, R. A., & Menon, R. S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1200 · Cited by 280
Noise contributions to the fMRI signal: An overview
Liu, T. T. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.09.008 · Cited by 275
Low-frequency BOLD fluctuations demonstrate altered thalamocortical connectivity in schizophrenia
Welsh, R. C., Chen, A. C., & Taylor, S. F. (2010) · Schizophrenia Bulletin · doi:10.1093/schbul/sbn145 · Cited by 181
Developmental alterations of frontal-striatal-thalamic connectivity in obsessive-compulsive disorder
Fitzgerald, K. D., Welsh, R. C., Stern, E. R., Angstadt, M., Hanna, G. L., Abelson, J. L., & Taylor, S. F. (2011) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1016/j.jaac.2011.06.011 · Cited by 165
Evaluating fMRI preprocessing pipelines
Strother, S. C. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1607667 · Cited by 169
Resting state connectivity correlates with drug and placebo response in fibromyalgia patients
Schmidt-Wilcke, T., Ichesco, E., Hampson, J. P., Kairys, A., Peltier, S., Harte, S., Clauw, D. J., & Harris, R. E. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.09.007 · Cited by 122
Physiological noise reduction for arterial spin labeling functional MRI
Restom, K., Behzadi, Y., & Liu, T. T. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.026 · Cited by 101
Functional magnetic resonance imaging: A review of methodological aspects and clinical applications
Hennig, J., Speck, O., Koch, M. A., & Weiller, C. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10330 · Cited by 100
Svedin, B. T., Payne, A., & Parker, D. L. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25860 · Cited by 30
Metadata
- Authors
- Pfeuffer, J., Van de Moortele, P., Ugurbil, K., Hu, X., & Glover, G. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-01-23
- Volume
- 47
- Issue
- 2
- Pages
- 344-353
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2114401183
- Cited by
- 216
- References
- 1
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.