Four‐angle saturation transfer (FAST) method for measuring creatine kinase reaction rates in vivo
Open accessThe DOI matches its Crossref record.
Abstract
A new fast method of measuring kinetic reaction rates for two‐site chemical exchange is described. The method employs saturation transfer magnetic resonance spectroscopy (MRS) and acquisition of only four spectra under partially saturated, high signal‐to‐noise ratio (SNR) conditions. In two acquisitions one of the exchanging species is saturated; the other two employ a control saturation. Each pair of acquisitions is applied with two different flip angles, and the equilibrium magnetization, relaxation times, and reaction rates are calculated therefrom. This four‐angle saturation transfer (FAST) method is validated theoretically using the Bloch equations modified for two‐state chemical exchange. Potential errors in the rate measurements due to the effects of exchange are evaluated for creatine kinase (CK) metabolism modeled for skeletal and heart muscle, and are found to be <5% for forward CK flux rates of 0.05 ≤ kf ≤ 1.0 s–1, and up to a 90% depletion of phosphocreatine (PCr). The effect of too much or too little saturating irradiation on FAST appears to be comparable to that of the conventional saturation transfer method, although the relative performance deteriorates when spillover irradiation cuts the PCr signal by 50% or more. “FASTer” and “ FASTest” protocols are introduced for dynamic CK studies wherein [PCr] and/or kf changes. These protocols permit the omission of one or two of the four acquisitions in repeat experiments, and the missing information is recreated from initial data via a new iterative algorithm. The FAST method is validated empirically in phosphorus (31 P) MRS studies of human calf muscle at 1.5 T. FAST measurements of 10 normal volunteers yielded the same CK reaction rates measured by the conventional method (0.29 ± 0.06 s–1) in the same subjects, but an average of seven times faster. Application of the FASTer algorithm to these data correctly restored missing information within seven iterations. Finally, the FAST method was combined with 1D spatially localized 31 P MRS in a study of six volunteers, yielding the same kf values independent of depth, in total acquisition times of 17–39 min. These timesaving FAST methods are enabling because they permit localized measurements of metabolic flux, which were previously impractical due to intolerably long scan times. Magn Reson Med 47:850– 863, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 40
- Jennings RB, 1981, Lethal myocardial ischemic injury, Am J Pathol, 102, 241
- Ingwall JS, 1993, Is cardiac failure a consequence of decreased energy reserve?, Circulation, 87, VII58
- 10.1126/science.3726553 · DOI · Paper page
- Bottomley PA, 1989, Rapid, reliable in vivo assays of phosphate metabolites by nuclear magnetic resonance, Clin Chem, 35, 392, 10.1093/clinchem/35.3.392 · DOI · Paper page
- 10.1161/01.CIR.92.1.15 · DOI · Paper page
- 10.1002/mrm.1910350507 · DOI · Paper page
- 10.1148/radiology.187.1.8451417 · DOI · Paper page
- 10.1006/jmrb.1993.1056 · DOI · Paper page
- 10.1148/radiology.204.2.9240527 · DOI · Paper page
- 10.1016/S0140-6736(97)06402-7 · DOI · Paper page
- 10.1073/pnas.74.12.5551 · DOI · Paper page
- 10.1021/bi00583a032 · DOI · Paper page
- 10.1016/0014-5793(82)80916-2 · doi:10.1016/0014-5793(82)80916-2
- 10.1021/bi00341a035 · doi:10.1021/bi00341a035
- 10.1021/bi00349a012 · DOI
- 10.1021/bi00393a021 · DOI · Paper page
- 10.1002/mrm.1910110106 · DOI
- 10.1002/mrm.1910320120 · DOI
- 10.1016/0022-2364(87)90279-4 · doi:10.1016/0022-2364(87)90279-4
- 10.1096/fasebj.3.14.2629743 · DOI · Paper page
- 10.1073/pnas.88.19.8372 · DOI
- 10.1016/0022-2364(92)90201-H · doi:10.1016/0022-2364(92)90201-h
- 10.1002/mrm.1910380408 · DOI · Paper page
- 10.1002/mrm.1910090107 · doi:10.1002/mrm.1910090107
- OuwerkerkR LeeR WeissRG BottomleyP.A new FAST method for in vivo measurement of chemical exchange rates. In: Proceedings of the 8th Annual Meeting of ISMRM Denver 2000. p421.
- 10.1006/jmrb.1994.1070 · doi:10.1006/jmrb.1994.1070
- 10.1006/jmre.2000.2166 · DOI
- 10.1063/1.1719961 · DOI · Paper page
- 10.1016/0022-2364(91)90137-I · DOI · Paper page
- 10.1006/jmra.1993.1162 · DOI
- 10.1002/nbm.1940010408 · doi:10.1002/nbm.1940010408
- 10.1006/jmrb.1993.1045 · doi:10.1006/jmrb.1993.1045
- 10.1007/BF02592247 · DOI
- 10.1016/0022-2364(86)90332-X · doi:10.1016/0022-2364(86)90332-x
- 10.1006/jmre.2000.2018 · doi:10.1006/jmre.2000.2018
- 10.1006/jmre.2000.2124 · doi:10.1006/jmre.2000.2124
- 10.1002/1522-2594(200006)43:6<810::AID-MRM6>3.0.CO;2-J · doi:10.1002/1522-2594(200006)43:6<810::aid-mrm6>3.0.co;2-j
- 10.1002/mrm.1910370524 · doi:10.1002/mrm.1910370524
- 10.1056/NEJM199012063232304 · DOI · Paper page
- 10.1006/jmre.1997.1230 · doi:10.1006/jmre.1997.1230
Cited by
ATP flux through creatine kinase in the normal, stressed, and failing human heart
Weiss, R. G., Gerstenblith, G., & Bottomley, P. A. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408962102 · Cited by 350
Self-citationIn Vivo Magnetic Resonance Spectroscopy in Cancer
Gillies, R. J., & Morse, D. L. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100411 · Cited by 261
Altered creatine kinase adenosine triphosphate kinetics in failing hypertrophied human myocardium
Smith, C. S., Bottomley, P. A., Schulman, S. P., Gerstenblith, G., & Weiss, R. G. (2006) · Circulation · doi:10.1161/circulationaha.106.613646 · Cited by 204
Self-citationTurakhia, M. P., Hoang, D. D., Zimetbaum, P., Miller, J. D., Froelicher, V. F., Kumar, U. N., Xu, X., Yang, F., & Heidenreich, P. A. (2013) · American Journal of Cardiology · doi:10.1016/j.amjcard.2013.05.017 · Cited by 53
Self-citation
Metadata
- Authors
- Bottomley, P. A., Ouwerkerk, R., Lee, R. F., & Weiss, R. G.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-04-22
- Volume
- 47
- Issue
- 5
- Pages
- 850-863
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1973158590
- Cited by
- 95
- References
- 0
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Four‐angle saturation transfer (FAST) method for measuring creatine kinase reaction rates in vivo. https://app.cochat.ai/papers/10.1002/mrm.10130
- The paper
- Bottomley, P. A., Ouwerkerk, R., Lee, R. F., & Weiss, R. G. (2002). Four‐angle saturation transfer (FAST) method for measuring creatine kinase reaction rates in vivo. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10130
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.