Total creatine in muscle: imaging and quantification with proton MR spectroscopy.
The DOI matches its Crossref record.
Abstract
PURPOSE: To provide a noninvasive method of imaging and quantifying total creatine (phosphorylated plus unphosphorylated) in human muscle with proton magnetic resonance (MR) spectroscopy. MATERIALS AND METHODS: Water-suppressed, long echo time, stimulated-echo hydrogen-1 chemical shift imaging and short echo time unsuppressed chemical shift imaging were performed on the lower legs of 10 healthy volunteers at rest. Spatial resolution was 4.5-8.0 cm3. Water signals in unsuppressed data sets were quantified and used as chemical shift and concentration references. Images of the integrated N-CH3 resonance assigned to total creatine were extracted from the water-suppressed chemical shift image data. Correlations between the total creatine, lipid, and water signals from the same voxels were tested. The concentration of total creatine in skeletal muscle was calculated from the ratio of the relaxation-corrected N-CH3 and water signals from the same voxels. RESULTS: Total creatine was localized to muscle bundles. Lipid signals contributed less than 6% to the variance of total creatine signal on images and in measurements and did not correlate with total creatine in the same voxels (P > .1). Total creatine and unsuppressed water signals were positively correlated (P < .0001). MR spectroscopy yielded a total creatine value of 36.2 mmol/kg wet weight +/- 5.0, consistent with prior biopsy data. CONCLUSION: H-1 MR spectroscopy can be used to image and noninvasively quantify total creatine in human muscle. Its use could improve the understanding of the role of altered creatine metabolism in muscle disease and aid quantification of the response to creatine therapies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
van Zijl, P. C. M., Lam, W. W., Xu, J., Knutsson, L., & Stanisz, G. J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.045 · Cited by 339
Kemp, G. J., Meyerspeer, M., & Moser, E. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1192 · Cited by 312
Fasting for 72 h increases intramyocellular lipid content in nondiabetic, physically fit men
Stannard, S. R., Thompson, M. W., Fairbairn, K., Huard, B., Sachinwalla, T., & Thompson, C. H. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00108.2002 · Cited by 108
“Total creatine was calculated as follows (7): 1) total creatine CH3 signal, measured at 3.”
MethodRico‐Sanz, J., Hajnal, J. V., Thomas, E. L., Mierisová, Ŝ., Ala‐Korpela, M., & Bell, J. D. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.615bk.x · Cited by 88
“…IT and ET was as determined by Schick et al. (1993), for protons from Cho as the average of values measured by Bruhn et al. (1991) and Schick et al. (1993), and for protons from TCr and water as the average of values reported by Bruhn et al. (1991), Schick et al. (1993) and Bottomley et al. (1997).”
MethodZehnder, M., Christ, E. R., Ith, M., Acheson, K. J., Pouteau, E., Kreis, R., Trepp, R., Diem, P., Boesch, C., & Décombaz, J. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0279-5 · Cited by 39
Metadata
- Authors
- Bottomley, P. A., Lee, Y., & Weiss, R. G.
- Venue
- Radiology
- Published
- 1997-08
- Volume
- 204
- Issue
- 2
- Pages
- 403-410
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2062277520
- Cited by
- 79
- References
- 0
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Total creatine in muscle: imaging and quantification with proton MR spectroscopy. https://app.cochat.ai/papers/10.1148/radiology.204.2.9240527
- The paper
- Bottomley, P. A., Lee, Y., & Weiss, R. G. (1997). Total creatine in muscle: imaging and quantification with proton MR spectroscopy. Radiology. https://doi.org/10.1148/radiology.204.2.9240527
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.