The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Proton T2 relaxation study of water, N‐acetylaspartate, and creatine in human brain using Hahn and Carr‐Purcell spin echoes at 4T and 7T
Open accessAbstract
Carr‐Purcell and Hahn spin‐echo (SE) measurements were used to estimate the apparent transverse relaxation time constant (T) of water and metabolites in human brain at 4T and 7T. A significant reduction in the T values of proton resonances (water, N‐acetylaspartate, and creatine/phosphocreatine) was observed with increasing magnetic field strength and was attributed mainly to increased dynamic dephasing due to increased local susceptibility gradients. At high field, signal loss resulting from T decay can be substantially reduced using a Carr‐Purcell‐type SE sequence. Magn Reson Med 47:629–633, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Transient decrease in water diffusion observed in human occipital cortex during visual stimulation
Darquié, A., Poline, J.-B., Poupon, C., Saint-Jalmes, H., & Le Bihan, D. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.151125698 · Cited by 194
Cited by
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Whole-body MRI at high field: technical limits and clinical potential
Schick, F. (2005) · European Radiology · doi:10.1007/s00330-005-2678-0 · Cited by 314
High magnetic field water and metabolite proton T1 and T2 relaxation in rat brain in vivo
de Graaf, R. A., Brown, P. B., McIntyre, S., Nixon, T. W., Behar, K. L., & Rothman, D. L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20946 · Cited by 304
Kaiser, L. G., Schuff, N., Cashdollar, N., & Weiner, M. W. (2005) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2004.07.001 · Cited by 251
Mangia, S., Giove, F., Tkáč, I., Logothetis, N. K., Henry, P.-G., Olman, C. A., Maraviglia, B., Di Salle, F., & Uğurbil, K. (2009) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2008.134 · Cited by 161
“Magnetic fields up to 7 T have now been used for human spectroscopy applications (Michaeli et al, 2002; Terpstra et al, 2002; Tkac et al, 2001), leading to the reliable quantification of a high number of brain metabolites.”
Self-citation
Metadata
- Authors
- Michaeli, S., Garwood, M., Zhu, X., DelaBarre, L., Andersen, P., Adriany, G., Merkle, H., Ugurbil, K., & Chen, W.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-03-28
- Volume
- 47
- Issue
- 4
- Pages
- 629-633
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2167234332
- Cited by
- 198
- References
- 2
- FWCI
- 8.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Proton T2 relaxation study of water, N‐acetylaspartate, and creatine in human brain using Hahn and Carr‐Purcell spin echoes at 4T and 7T. https://app.cochat.ai/papers/10.1002/mrm.10135
- The paper
- Michaeli, S., Garwood, M., Zhu, X., DelaBarre, L., Andersen, P., Adriany, G., Merkle, H., Ugurbil, K., & Chen, W. (2002). Proton T2 relaxation study of water, N‐acetylaspartate, and creatine in human brain using Hahn and Carr‐Purcell spin echoes at 4T and 7T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10135
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.