The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Characterization of anisotropy in high angular resolution diffusion‐weighted MRI
Open accessAbstract
The methods of group theory are applied to the problem of characterizing the diffusion measured in high angular resolution MR experiments. This leads to a natural representation of the local diffusion in terms of spherical harmonics. In this representation, it is shown that isotropic diffusion, anisotropic diffusion from a single fiber, and anisotropic diffusion from multiple fiber directions fall into distinct and separable channels. This decomposition can be determined for any voxel without any prior information by a spherical harmonic transform, and for special cases the magnitude and orientation of the local diffusion may be determined. Moreover, non‐diffusion–related asymmetries produced by experimental artifacts fall into channels distinct from the fiber channels, thereby allowing their separation and a subsequent reduction in noise from the reconstructed fibers. In the case of a single fiber, the method reduces identically to the standard diffusion tensor method. The method is applied to normal volunteer brain data collected with a stimulated echo spiral high angular resolution diffusion‐weighted (HARD) acquisition. Magn Reson Med 47:1083–1099, 2002. Published 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages
Cox, R. W. (1996) · Computers and Biomedical Research · doi:10.1006/cbmr.1996.0014 · Cited by 10,913
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Encyclopedia of Mathematics and its Applications.
L., Y. L., Jones, W. B., & Thron, W. J. (1982) · Mathematics of Computation · doi:10.2307/2007638 · Cited by 4,119
Mathematical Methods for Physicists
Arfken, G., & Mathews, J. (1972) · American Journal of Physics · doi:10.1119/1.1988084 · Cited by 4,038
Estimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Principles of Nuclear Magnetic Resonance Microscopy
Callaghan, P. T. (1991) · doi:10.1093/oso/9780198539445.001.0001 · Cited by 3,599
Mathematical Methods for Physicists
Arfken, G., & Mullin, A. A. (1967) · American Journal of Physics · doi:10.1119/1.1973757 · Cited by 2,688
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Linear Algebra and Its Applications
I., E., & Strang, G. (1976) · Mathematics of Computation · doi:10.2307/2005411 · Cited by 1,871
Group Theory - And its Application to the Quantum Mechanics of Atomic Spectra
(1959) · Pure and Applied Physics · doi:10.1016/b978-0-12-750550-3.x5001-0 · Cited by 1,631
Mathematical Methods for Physicists
(2013) · Elsevier eBooks · doi:10.1016/c2009-0-30629-7 · Cited by 1,375
Group Theory and Its Application to the Quantum Mechanics of Atomic Spectra
Wigner, E. P., & Fano, U. (1960) · American Journal of Physics · doi:10.1119/1.1935822 · Cited by 952
Stejskal, E. O. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1696526 · Cited by 894
Computing Fourier Transforms and Convolutions on the 2-Sphere
Driscoll, J. R., & Healy, D. M. (1994) · Advances in Applied Mathematics · doi:10.1006/aama.1994.1008 · Cited by 881
A simplified method to measure the diffusion tensor from seven MR images
Basser, P. J., & Pierpaoli, C. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390610 · Cited by 583
Anisotropic diffusion in human white matter: demonstration with MR techniques in vivo.
Chenevert, T. L., Brunberg, J. A., & Pipe, J. G. (1990) · Radiology · doi:10.1148/radiology.177.2.2217776 · Cited by 503
Angular Momentum in Quantum Physics: Theory and Application
Biedenharn, L. C., & Louck, J. D. (1984) · Cited by 491
Diffusion and Perfusion Magnetic Resonance Imaging: Applications to Functional MRI
Bihan, D. L., & Warach, S. J. (1995) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199509000-00032 · Cited by 397
Anisotropy in high angular resolution diffusion-weighted MRI
Frank, L. R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1125 · Cited by 389
Self-citationA fast transform for spherical harmonics
Mohlenkamp, M. J. (1997) · Journal of Fourier Analysis and Applications · doi:10.1007/bf01261607 · Cited by 237
Elliott, J. P., & Dawber, P. G. (1979) · doi:10.1007/978-1-349-07635-2 · Cited by 231
Anisotropy in diffusion‐weighted MRI
Moseley, M. E., Kucharczyk, J., Asgari, H. S., & Norman, D. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190222 · Cited by 198
Detection of sea-water motion by nuclear precession
Hahn, E. L. (1960) · Journal of Geophysical Research · doi:10.1029/jz065i002p00776 · Cited by 197
Mapping fiber orientation spectra in cerebral white matter with Fourier-transform diffusion MRI
Wedeen, V. J., Reese, T. G., Tuch, D. S., Weigel, M., Dou, J., Weisskoff, R. M., & Chessler, D. (2000) · Cited by 188
High Angular Resolution Diffusion Imaging of the Human Brain
Tuch, D. S. (1999) · Cited by 156
Doran, M., Hajnal, J. V., van Bruggen, N., King, M. D., Young, I. R., & Bydder, G. M. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199011000-00001 · Cited by 144
Hsu, E. W., & Mori, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340210 · Cited by 114
Research works printed but not linked: 7
- LeBihan D, 1995, Diffusion and perfusion magnetic resonance imaging
- MoseleyME CohenY MintorovitchJ ChileuittL TsurudaJ NormanD WeinsteinP.Evidence of anisotropic self‐diffusion in cat brain. In: Proceedings of the 8th Annual Meeting of SMRM Amsterdam 1989. p136.
- FrankLR.Characterization of anisotropy in high angular resolution diffusion weighted MRI. In: Proceedings of the 9th Annual Meeting of ISMRM Glasgow Scotland 2001. p1531.
- 10.1007/978-1-349-07637-6 · doi:10.1007/978-1-349-07637-6
- Ritchie DW, 1999, Fast computation, rotation, and comparison of low resolution spherical harmonic molecular surfaces, J Math Chem, 20, 383
- 10.1016/0021-9991(85)90189-5 · doi:10.1016/0021-9991(85)90189-5
- 10.1175/1520-0493(1993)121<3415:TVHTMF>2.0.CO;2 · doi:10.1175/1520-0493(1993)121<3415:tvhtmf>2.0.co;2
Cited by
Characterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
Diffusion tensor imaging of the brain
Alexander, A. L., Lee, J. E., Lazar, M., & Field, A. S. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.011 · Cited by 2,747
Tournier, J.-D., Calamante, F., & Connelly, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.016 · Cited by 2,188
Tournier, J.-D., Calamante, F., Gadian, D. G., & Connelly, A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.037 · Cited by 1,635
Jeurissen, B., Tournier, J.-D., Dhollander, T., Connelly, A., & Sijbers, J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.061 · Cited by 1,454
Metadata
- Authors
- Frank, L. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-06
- Volume
- 47
- Issue
- 6
- Pages
- 1083-1099
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2115582941
- Cited by
- 510
- References
- 28
- FWCI
- 20.76
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.